@@ -80,6 +80,46 @@ different absorber thickness are shown in \cref{tab:proton_cdc_hitrate}.
|
||||
\label{tab:proton_cdc_hitrate}
|
||||
\end{table}
|
||||
|
||||
%\begin{table}[htb]
|
||||
%\begin{center}
|
||||
%\begin{tabular}{S S S S S}
|
||||
%\toprule
|
||||
%{\textbf{Absorber}} &{\textbf{Inner wall}} & {\textbf{Total CFRP}}&
|
||||
%{\textbf{Proton hit rate}} & {\textbf{Proton hit rate}}\\
|
||||
%{\textbf{thickness}} &{\textbf{thickness}} & {\textbf{thickness}}&
|
||||
%{\textbf{Phase-I TDR}} & {\textbf{New estimation}}\\
|
||||
%{(\si{\mm})} & {(\si{\mm})} & {(\si{\mm})} & {(\si{\Hz})}& {(\si{\Hz})}\\
|
||||
%\midrule
|
||||
%1 &0.5&1.5 & 4E+3 & 2 \\
|
||||
%0.5 &0.5&1.0 & 11E+3& 126 \\
|
||||
%0 &0.5&0.5 & 30E+3& 1436 \\
|
||||
%\bottomrule
|
||||
%\end{tabular}
|
||||
%\end{center}
|
||||
%\caption{CDC proton hit rates at different configuration of proton absorber
|
||||
%and inner wall. The momentum spreads for \SI{0.5}{\mm} thick inner wall are
|
||||
%taken from \cref{tab:comet_absorber_impact}.}
|
||||
%\label{tab:proton_cdc_hitrate}
|
||||
%\end{table}
|
||||
|
||||
%\begin{table}[htb]
|
||||
%\begin{center}
|
||||
%\begin{tabular}{S S S S S S}
|
||||
%\toprule
|
||||
%{\textbf{Absorber}} &{\textbf{Inner wall}} & {\textbf{Total CFRP}}& {\textbf{Proton}} & {\textbf{Momentum}} & {\textbf{Integrated charge}}\\
|
||||
%{\textbf{thickness}} &{\textbf{thickness}} & {\textbf{thickness}}& {\textbf{hit rate}} &{\textbf{spread $\Delta p$}} &{\textbf{300 days}}\\
|
||||
%{(\si{\mm})} & {(\si{\mm})} & {(\si{\mm})} & {(\si{\Hz})} & {(\si{\keV\per\cc)}} &{(mC/cm)}\\
|
||||
%\midrule
|
||||
%1 &0.5&1.5 & 2 & 195 & 25\\
|
||||
%0.5 &0.5&1.0 & 126 & 167 & 60\\
|
||||
%0 &0.5&0.5 & 1436 & 133 & 160\\
|
||||
%\bottomrule
|
||||
%\end{tabular}
|
||||
%\end{center}
|
||||
%\caption{CDC proton hit rates at different configuration of proton absorber
|
||||
%and inner wall. The momentum spreads for \SI{0.5}{\mm} thick inner wall are
|
||||
%taken from \cref{tab:comet_absorber_impact}.}
|
||||
%\end{table}
|
||||
At the baseline design of \SI{0.5}{\mm}, the hit rate is only \SI{126}{\Hz},
|
||||
much smaller than the current estimation at \SI{34}{\kHz}. Even without the
|
||||
absorber, proton hit rate remains low at \SI{1.4}{\kHz}.
|
||||
|
||||