\chapter{The AlCap Run 2013}
|
|
\label{cha:the_alcap_run_2013}
|
|
\thispagestyle{empty}
|
|
The first run of the AlCap experiment was performed at the $\pi$E1 beam line
|
|
area, PSI (Figure~\ref{fig:psi_exp_hall_all}) from November 26 to December 23,
|
|
2013. The goal of the run was to measure protons rate and spectrum following
|
|
muon capture on aluminium.
|
|
|
|
\begin{figure}[p]
|
|
\centering
|
|
\includegraphics[height=0.85\textheight]{figs/psi_exp_hall_all}
|
|
\caption{Layout of the PSI experimental hall, $\pi$E1 experimental area is
|
|
marked with the red circle. \\Image taken from
|
|
\url{http://www.psi.ch/num/FacilitiesEN/HallenplanPSI.png}}
|
|
\label{fig:psi_exp_hall_all}
|
|
\end{figure}
|
|
|
|
\section{Experimental set up}
|
|
\label{sec:experimental_set_up}
|
|
The low energy muons from the $\pi$E1 beam line were stopped in thin aluminium
|
|
and silicon targets, and charged particles emitted were measured by two pairs
|
|
of silicon detectors inside of a vacuum vessel
|
|
(Figure~\ref{fig:alcap_setup_detailed}). A stopped muon event is defined by
|
|
a group of upstream detectors and a muon veto plastic scintillator.
|
|
The number of stopped muons is monitored by a germanium detector placed outside
|
|
of the vacuum chamber. In addition, several plastic scintillators were used to
|
|
provide veto signals for the silicon and germanium detectors. Two liquid
|
|
scintillators for neutron measurements were also tested in this run.
|
|
\begin{figure}[htbp]
|
|
\centering
|
|
\includegraphics[width=0.65\textwidth]{figs/alcap_setup_detailed}
|
|
\caption{AlCap detectors: two silicon packages inside the vacuum vessel,
|
|
muon beam detectors including plastic scintillators and a wire chamber,
|
|
germanium detector and veto plastic scintillators.}
|
|
\label{fig:alcap_setup_detailed}
|
|
\end{figure}
|
|
|
|
\subsection{Muon beam and vacuum chamber}
|
|
Muons in the $\pi$E1 beam line are decay products of pions created
|
|
as a 590~\mega\electronvolt\ proton beam hit a thick carbon target
|
|
(E-target in Figure~\ref{fig:psi_exp_hall_all}). The beam line was designed to
|
|
deliver muons with momenta ranging from 10 to 500~\mega\electronvolt\per\cc\
|
|
and
|
|
momentum spread from 0.26 to 8.0\%. These parameters can be selected by
|
|
changing various magnets and slits shown in
|
|
Figure~\ref{fig:psi_piE1_elements}~\cite{Foroughli.1997}.
|
|
|
|
\begin{figure}[htb]
|
|
\centering
|
|
\includegraphics[width=0.7\textwidth]{figs/psi_piE1_elements}
|
|
\caption{The $\pi$E1 beam line}
|
|
\label{fig:psi_piE1_elements}
|
|
\end{figure}
|
|
|
|
One of the main requirements of the AlCap experiment was a low energy muon beam
|
|
with narrow momentum bite in order to achieve a high fraction of stopping muons
|
|
in the very thin targets. In this Run 2013, muons from 28 to
|
|
45~\mega\electronvolt\per\cc\ and momentum spread of 1\% and 3\%were used.
|
|
|
|
For part of the experiment the target was replaced with one of the silicon
|
|
detector packages allowed an accurate momentum and range calibration
|
|
%(via range-energy relations)
|
|
of the beam at the target. Figure~\ref{fig:Rates} shows the measured muon rates
|
|
as a function of momentum for two different momentum bites.
|
|
Figure~\ref{fig:Beam} shows an example of the resulting energy spectra.
|
|
\begin{figure}[htbp]
|
|
\centering
|
|
\includegraphics[width=0.6\textwidth]{figs/Rates.png}
|
|
\caption{Measured muon rate (kHz) at low momenta. Momentum bite of 3 and 1 \%
|
|
FWHM, respectively.}
|
|
\label{fig:Rates}
|
|
\end{figure}
|
|
|
|
\begin{figure}[htbp]
|
|
\centering
|
|
\includegraphics[width=0.9\textwidth]{figs/beam.pdf}
|
|
\caption{Energy deposition at 36.4 MeV/c incident muon beam in an
|
|
1500-\micron-active
|
|
target. The peak at low energy is due to beam electrons, the
|
|
peaks at higher energies are due to muons. Momentum bite of 1 and 3\% FWHM
|
|
on left and right hand side, respectively.} \label{fig:Beam}
|
|
\end{figure}
|
|
|
|
The targets and charged particle detectors are installed inside the vacuum
|
|
chamber as shown in Figure~\ref{fig:alcap_setup_detailed}. The muon beam enters
|
|
from the right of the image and hits the target, which is placed at the
|
|
centre of the vacuum chamber and orientated at 45 degrees to the beam axis.
|
|
The side walls and bottom flange of the vessel provide several
|
|
vacuum-feedthroughs for the high voltage and signal cables for the silicon and
|
|
scintillator detectors inside the chamber.
|
|
In addition, the chamber is equipped with several lead collimators
|
|
%so that muons that are not captured in the target would quickly decay.
|
|
to quickly capture muons that do not stop in the actual target.
|
|
%\begin{figure}[htbp]
|
|
%\centering
|
|
%\includegraphics[width=0.55\textwidth]{figs/SetupOverview.jpg}
|
|
%\caption{Vacuum chamber in beam line}
|
|
%\label{fig:SetupOverall}
|
|
%\end{figure}
|
|
|
|
%It is known fact that there is a risk of sparkling between the electrodes of
|
|
%a silicon detector in the low vacuum region of $10^{-3}$ mbar.
|
|
%An interlock mechanism was installed to prevent the bias of the
|
|
%silicon detectors from being applied before the safe vacuum level.
|
|
For a safe operation of the silicon detector, a vacuum of $<10^{-4}$\,mbar was
|
|
necessary. With the help of the vacuum group of PSI, we could consistently
|
|
reach $10^{-4}$\,mbar within 45 minutes after closure of the chamber's top
|
|
flange.
|
|
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
|
|
|
|
\subsection{Silicon detectors}
|
|
The main detectors for proton measurement in the Run 2013 were four large area
|
|
silicon detectors. The silicon detectors were grouped into two detector
|
|
packages located symmetrically at 90 degrees of the nominal muon beam path, SiL
|
|
and SiR in Figure~\ref{fig:alcap_setup_detailed}. Each arm consists of: one
|
|
$\Delta$E counter, a 65-\micro\meter-thick silicon detector, divided into
|
|
4 quadrants; one E counter made from 1500-\micron-thick silicon; and one
|
|
plastic scintillator to identify electrons or high energy protons that pass
|
|
through the silicon. The area of each of these silicon detectors and the
|
|
scintillators is $50\times50 \textrm{mm}^2$.
|
|
|
|
The detectors were named according to their positions relative to the muon
|
|
view: the SiL package contains the thin
|
|
detector SiL1 and thick detector SiL2; the SiR package has SiR1 and SiR2
|
|
accordingly. Each quadrant of the thin detectors were also numbered from 1 to
|
|
4, i.e. SiL1-1, SiL1-2, SiL1-3, SiL1-4, SiR1-1, SiR1-2, SiR1-3,
|
|
SiR1-4.
|
|
|
|
Bias for the four silicon detectors was supplied by an ORTEC 710 NIM module,
|
|
which has a vacuum interlock input to prevent biasing before the safe vacuum
|
|
level has been reached. Typical voltage to fully depleted the detectors were
|
|
-300~\volt\ and -10~\volt\ for the thick and thin silicon detectors
|
|
respectively. The leakage currents at the operating voltages are less than
|
|
1.5~\micro\ampere\ for the thick detectors, and about 0.05~\micro\ampere\
|
|
for the thin ones (see Figure~\ref{fig:si_leakage}).
|
|
\begin{figure}[htb]
|
|
\centering
|
|
\includegraphics[width=0.85\textwidth]{figs/si_leakage}
|
|
\caption{Leakage currents of the silicon detectors under bias.}
|
|
\label{fig:si_leakage}
|
|
\end{figure}
|
|
|
|
The fact that a detector were fully depleted was checked by putting
|
|
a calibration source $^{241}\textrm{Am}$ at its ohmic side, and observing the
|
|
output
|
|
pulse height on an oscilloscope. One would expect that the maximum pulse height
|
|
increases as the bias is raised until the voltage of fully depleted. The effect
|
|
can also be seen on the pulse height spectrum as in
|
|
Figure~\ref{fig:sir2_bias_alpha}.
|
|
\begin{figure}[htb]
|
|
\centering
|
|
\includegraphics[width=0.75\textwidth]{figs/sir2_bias_alpha}
|
|
\caption{$^{241}\textrm{Am}$ spectra in cases of fully depleted (top), and
|
|
partly depleted (bottom).}
|
|
\label{fig:sir2_bias_alpha}
|
|
\end{figure}
|
|
|
|
%It is known that the noise level of a silicon detector increases linearly with
|
|
%its capacity. So both noise and pick-up suppression had been carefully
|
|
%optimised in the real PSI accelerator environment, particularly for the thin
|
|
%silicon detectors which have a large capacity of 1~\nano\farad~in each
|
|
%quadrant.
|
|
%After improving the feed-through flanges during the set-up phase of the
|
|
%experiment with isolated ground connections, good electronic resolution of
|
|
%55--76~\kilo\electronvolt\ FWHM was achieved in the thin silicon detectors.
|
|
%So achieving good energy resolution was particularly challenging
|
|
%for the thin silicon detector, as each quadrant had a large capacity of
|
|
%1~\nano\farad. Both
|
|
%noise and pick-up suppression had been carefully optimized in the real PSI
|
|
%accelerator environment.
|
|
%Optimization of the fast timing signals proved another challenge.
|
|
%The energy calibration for the silicon detectors were done
|
|
%by several means:
|
|
%\begin{enumerate}
|
|
%\item An $^{241}\textrm{Am}$ alpha source: the main alpha
|
|
%particles have energies of 5.484~\mega\electronvolt\ (85.2\%) and
|
|
%5.442~\mega\electronvolt\ (12.5\%). The source emits 79.5
|
|
%$\alpha\per\second$ in 2$\pi$~\steradian.
|
|
%\item Test pulse with a fixed amplitude: the preamplifiers used for the
|
|
%silicon detectors are come with the manufacturer's specification on the
|
|
%response, namely a 66 \milli\volt\ fed into the test input will produce an
|
|
%output equivalent to that of a 1 \mega\electronvolt\ energy deposition.
|
|
%\item Minimum ionisation particles
|
|
%(MIPs): electrons in the beam are MIPs with a nominal deposit energy of
|
|
%388~\electronvolt\per\micro\meter\ Si. This is only applicable for thick
|
|
%silicon detectors because the energy deposit is large enough and the energy
|
|
%resolution is good enough. During the run, this peak was observed to make
|
|
%sure the stability of the electronics.
|
|
%\item Muons with different momenta: the thick silicon detectors were placed
|
|
%at the target position during beam tuning period, allowed an accurate
|
|
%momentum and range calibration. This also only works with thick silicon
|
|
%detectors.
|
|
%\end{enumerate}
|
|
% subsection silicon_detectors (end)
|
|
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
|
|
\subsection{Upstream counters}
|
|
\label{sub:upstream_counters}
|
|
The upstream detector consists of three counters: a 500~$\mu$m thick
|
|
scintillator muon trigger counter ($\mu$SC); a muon anti-coincidence counter
|
|
($\mu$SCA) surrounding the trigger counter with a hole
|
|
of 35 \milli\meter\ in diameter to define the beam radius; and a multi-wire
|
|
proportional chamber ($\mu$PC) that uses 24 X wires and 24 Y wires at
|
|
2~\milli\meter~intervals.
|
|
|
|
The upstream detectors provide signal of an incoming muon as coincident hits on
|
|
the muon trigger and the wire chamber in anti-coincident with the muon
|
|
anti-coincidence counter.
|
|
This set of detectors along with their read-out system
|
|
belong to the MuSun experiment, which operated at the same beam line just
|
|
before our run. Thanks to the MuSun group, the detectors were well-tuned and
|
|
ready to be used in our run without any modification.
|
|
|
|
% subsection upstream_counters (end)
|
|
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
|
|
|
|
\subsection{Germanium detector}
|
|
%\begin{figure}[htbp]
|
|
%\centering
|
|
%\includegraphics[width=0.9\textwidth]{figs/neutron.png}
|
|
%\caption{Setup of two
|
|
%liquid scintillators outside the vacuum envelope for neutron detection.}
|
|
%\label{fig:neutron}
|
|
%\end{figure}
|
|
We used a germanium detector to normalise the number of stopped muons by
|
|
measuring characteristics muon X-rays from the target material. The primary
|
|
X-rays of interest are the 346.828~keV line for aluminium targets, and the
|
|
400.177 line for silicon targets. The energies and intensities of the X-rays
|
|
listed in Table~\ref{tab:xray_ref} follow measurement results from
|
|
Measday and colleagues~\cite{MeasdayStocki.etal.2007}.
|
|
\begin{table}[htb]
|
|
\begin{center}
|
|
\begin{tabular}{c l l l l }
|
|
\toprule
|
|
\textbf{Elements} & \textbf{Transition}
|
|
& \textbf{Energy} & \textbf{Intensity}\\
|
|
\midrule
|
|
$^{27}\textrm{Al}$ & $2p-1s$ & $346.828 \pm 0.002$ & $79.8\pm 0.8$\\
|
|
& $3p-1s$ & $412.87 \pm 0.05$ & $7.62\pm 0.15$\\
|
|
\midrule
|
|
$^{28}\textrm{Si}$ & $2p-1s$ & $400.177 \pm 0.005$ & $80.3\pm 0.8$\\
|
|
& $3p-1s$ & $476.80 \pm 0.05$ & $7.40 \pm 0.20$\\
|
|
\bottomrule
|
|
\end{tabular}
|
|
\end{center}
|
|
\caption{Reference values of major muonic X-rays from aluminium and silicon.}
|
|
\label{tab:xray_ref}
|
|
\end{table}
|
|
|
|
The germanium detector is
|
|
a GMX20P4-70-RB-B-PL, n-type, coaxial high purity germanium detector produced
|
|
by ORTEC. The detector was optimised for low energy gamma and X-rays
|
|
measurement with an ultra-thin entrance window of 0.5-mm-thick beryllium and
|
|
a 0.3-\micron-thick ion implanted contact (Figure~\ref{fig:ge_det_dimensions}).
|
|
This detector is equipped with a transistor reset preamplifier which,
|
|
according to the producer, enables it to work in an ultra-high rate environment
|
|
up to $10^6$ counts\per\second~ at 1~\mega\electronvolt.
|
|
\begin{figure}[htb]
|
|
\centering
|
|
\includegraphics[width=0.9\textwidth]{figs/ge_det_dimensions}
|
|
\caption{Dimensions of the germanium detector}
|
|
\label{fig:ge_det_dimensions}
|
|
\end{figure}
|
|
|
|
The detector was installed outside of the vacuum chamber at 32 cm from the
|
|
target, seeing the target through a 10-mm-thick aluminium window, behind
|
|
a plastic scintillator counter used to veto electrons. Liquid nitrogen
|
|
necessary for the operation of the detector had to be refilled every 8 hours.
|
|
A timer was set up in the data acquisition system to remind this.
|
|
|
|
\subsection{Plastic and liquid scintillators}
|
|
\label{sub:plastic_scintillators}
|
|
Apart from the scintillators in the upstream group, there were four other
|
|
plastic scintillators used as veto counters for:
|
|
\begin{itemize}
|
|
\item punch-through-the-target muons, ScVe
|
|
\item electrons and other high energy charged particles for germanium
|
|
detector (ScGe) and silicon detectors (ScL and ScR)
|
|
\end{itemize}
|
|
The ScL, ScR and ScVe were installed inside the vacuum vessel and were
|
|
optically connected to external PMTs by light-guides at the bottom flange.
|
|
|
|
We also set up two liquid scintillation counters for neutron measurements in
|
|
preparation for the next beam time where the neutron measurements will be
|
|
carried out.
|
|
% subsection plastic_scintillators (end)
|
|
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
|
|
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
|
|
\section{Front-end electronics and data acquisition system}
|
|
The front-end electronics of the AlCap experiment was simple since we employed
|
|
a trigger-less read out system with waveform digitisers and flash ADCs
|
|
(FADCs). As shown in Figure~\ref{fig:alcapdaq_scheme}, all plastic
|
|
scintillators signals were amplified by PMTs, then fed into the digitisers. The
|
|
signals from silicon and germanium detectors were preamplified, and
|
|
subsequently shaped by spectroscopy amplifiers and timing filter amplifiers
|
|
(TFAs) to provide energy and timing information.
|
|
\begin{figure}[htbp]
|
|
\centering
|
|
\includegraphics[width=0.99\textwidth]{figs/alcapdaq_scheme}
|
|
\caption{Schematic diagram of the electronics and DAQ used in the Run 2013}
|
|
\label{fig:alcapdaq_scheme}
|
|
\end{figure}
|
|
|
|
The germanium detector has its own transistor reset preamplifier
|
|
installed very close to the germanium crystal. Two ORTEC Model 142
|
|
preamplifiers were used for the thick silicon detectors. The timing outputs of
|
|
the preamplifiers were fed into three ORTEC Model 579 TFAs.
|
|
We used an ORTEC Model 673 to shape the germanium signal with 6~\micro\second
|
|
shaping time.
|
|
|
|
A more modern-style electronics was used for thin silicon detectors where the
|
|
preamplifier, shaping and timing amplifiers were implemented on one compact
|
|
package, namely a Mesytec MSI-8 box. This box has 8 channels, each channel
|
|
consists of one preamplifier board and one shaper-and-timing filter board which
|
|
can be fine-tuned independently. The shaping time was set to 1~\micro\second\
|
|
for all channels.
|
|
|
|
The detector system produced signals that differs significantly in time scale,
|
|
ranging from very fast (about 40~\nano\second\ from scintillators) to very slow
|
|
(several \micro\second\ from shaping outputs of semiconductor detectors). This
|
|
lead to the use of several sampling frequencies from 17~\mega\hertz\ to
|
|
250~\mega\hertz, and three types of digitisers were employed:
|
|
\begin{itemize}
|
|
\item custom-built 12-bit 170-MHz FADCs which was designed for the
|
|
MuCap experiment. Each FADC board has dimensions the same as those of
|
|
a single-width 6U VME module, but is hosted in a custom built crate due to
|
|
its different power supply mechanical structure. The FADC communicates with
|
|
a host computer through a 100-Mb/s Ethernet interface using a simple
|
|
Ethernet-level protocol. The protocol only allows detecting
|
|
incomplete data transfers but no retransmitting is possible due to the
|
|
limited size of the module's output buffer. The FADCs accept clock signal
|
|
at the frequency of 50~\mega\hertz\ then multiply that internally up to
|
|
170~\mega\hertz. Each channel on one board can run at different sampling
|
|
frequency not dependent on other channels. The FADC has 8 single-ended
|
|
LEMO inputs with 1~\volt pp dynamic range.
|
|
\item a 14-bit 100-MS/s CAEN VME FADC waveform digitiser model V1724. The
|
|
module houses 8 channels with 2.25~Vpp dynamic range on single-ended MCX
|
|
coaxial inputs. The digitiser features an optical link for transmission of
|
|
data to its host computer. All of 8 channels run at the same sampling
|
|
frequency and have one common trigger.
|
|
\item a 12-bit 250-MS/s CAEN desktop waveform digitizer model DT5720. This
|
|
digitiser is similar to the V1724, except for its form factor and maximum
|
|
sampling frequency. Although there is an optical link available, the module
|
|
is connected to its host computer through a USB 2.0 interface where data
|
|
transfer rate of 30 MB/s was determined to be good enough in our run
|
|
(actual data rate from this digitiser was typically about 5 MB/s during the
|
|
run). Communication with both CAEN digitisers was based on CAEN's
|
|
proprietary binary drivers and libraries.
|
|
\end{itemize}
|
|
All digitisers were driven by external clocks which were derived from the same
|
|
500-\mega\hertz\ master clock, a high precision RF signal generator Model SG382
|
|
of Stanford Research System.
|
|
|
|
The silicon detectors were read out by FADC boards feature network-based data
|
|
readout interface. To maximize the data throughput, each of the four FADC
|
|
boards was read out through separate network adapter.
|
|
The CAEN digitisers were used to read out
|
|
the germanium detector (timing and energy, slow signals) or scintillator
|
|
detectors (fast signals). For redundancy, all beam monitors ($\mu$SC, $\mu$SCA
|
|
and $\mu$PC) were also read out by a CAEN time-to-digital converter (TDC)
|
|
model V767 which was kindly provided by the MuSun experiment.
|
|
|
|
The Data Acquisition System (DAQ) of the AlCap experiment, so-called AlCapDAQ,
|
|
provided the readout of front-end electronics, event assembling, data logging,
|
|
hardware monitoring and control, and the run database of the experiment
|
|
(Figure~\ref{fig:alcapdaq_pcs}). It was based on MIDAS framework~\footnote{
|
|
MIDAS is a general purpose DAQ software system developed at PSI and TRIUMF:\\
|
|
\url{http://midas.triumf.ca}} and consisted of two circuits, {\em i})
|
|
a detector circuit for synchronous data readout from the front-end electronics
|
|
instrumenting detectors, and {\em ii}) a slow control circuit for asynchronous
|
|
periodic hardware monitoring (vacuum, liquid nitrogen
|
|
filling). The detector circuit consisted of three computers, two front-end
|
|
computers and one computer serving both as a front-end and as a back-end
|
|
processor. The slow circuit consisted of one computer. All computers were
|
|
running Linux operating system and connected into a private subnetwork.
|
|
|
|
%\hl{TODO: storage and shift monitor}
|
|
|
|
\begin{figure}[htb]
|
|
\centering
|
|
\includegraphics[width=0.95\textwidth]{figs/alcapdaq_pcs}
|
|
\caption{AlCapDAQ in the Run 2013. The {\ttfamily fe6} front-end is
|
|
a VME single board computer belongs to the MuSun group, reads out the
|
|
upstream detectors.}
|
|
\label{fig:alcapdaq_pcs}
|
|
\end{figure}
|
|
|
|
The data were collected as dead-time-free time segments of 110~ms, called
|
|
``block'', followed by about 10-ms-long time intervals used to complete data
|
|
readout and synchronize the DAQ. Such data collection approach was chosen to
|
|
maximize the data readout efficiency. During each 110-ms-long period, signals
|
|
from each detector were digitized independently by threshold crossing. The data
|
|
segment of each detector data were first written into on-board memories of
|
|
front-end electronics and either read out in a loop (CAEN TDCs and CAEN
|
|
digitizers) or streamed (FADCs) into the computer memories. The thresholds were
|
|
adjusted as low as possible and individually for each detector. The time
|
|
correlation between detectors would be established in the analysis stage.
|
|
|
|
At the beginning of each block, the time counter in each digitiser is reset to
|
|
ensure time alignment across all modules. The period of 110~ms was chosen to be:
|
|
{\em i} long enough compares to the time scale of several \micro\second\ of the
|
|
physics of interest, {\em ii} short enough so that there is no timer rollover
|
|
on any digitiser (a FADC runs at its maximum speed of 170~\mega\hertz\ could
|
|
handle up to about 1.5 \second\ with its 28-bit time counter).
|
|
|
|
To ease the task of handling data, the data collecting period was divided into
|
|
short runs, each run stopped when the logger had recorded 2 GB of data.
|
|
The data size effectively made each run last for about 5 minutes. The DAQ
|
|
automatically starts a new run with the same parameters after about 6 seconds.
|
|
The short period of each run also allows the detection, and helps to reduce the
|
|
influence of effects such as electronics drifting, temperature fluctuation.
|
|
|
|
\section{Data sets and statistics}
|
|
\label{sec:data_sets}
|
|
|
|
The main goal of this Run 2013 was to measure the rates and energy spectra of
|
|
protons following muon capture on aluminium. Also for normalisation and cross
|
|
checking against the existing experimental data, two types of measurements with
|
|
different targets were carried out for silicon targets:
|
|
\begin{itemize}
|
|
\item[(a)] an active, thick target similar to the set up
|
|
used by Sobottka and Wills~\cite{SobottkaWills.1968}. This provides
|
|
a cross-check against the existing experimental data. The silicon detector
|
|
package at the right hand side was moved to the target position with the
|
|
thick detector facing the muon beam in this set up.
|
|
\item[(b)] a passive, thin target and heavy charged particles were observed
|
|
by the two silicon packages. The measurement serves multiple purposes:
|
|
confirmation that the particle identification by dE/dx actually works,
|
|
separation of components of heavy charged particles emitted from the
|
|
silicon target.
|
|
\end{itemize}
|
|
|
|
As the emitted protons deposit a significant amount of energy in the target
|
|
material, thin targets and thus excellent momentum resolution of the low energy
|
|
muon beam are critical. Aluminium targets of 50-\micro\meter\ and
|
|
100~\micron\ thick were used. Although a beam with low momentum spread of
|
|
1\% is preferable, it was used for only a small portion of the run due to the
|
|
low beam rate (see Figure~\ref{fig:Rates}). The beam momentum for each target
|
|
was chosen to maximise the number of stopped muons. The collected data sets are
|
|
shown in Table~\ref{tb:stat}.
|
|
|
|
\begin{table}[htb!]
|
|
\begin{center}
|
|
\vspace{0.15cm}
|
|
\begin{tabular}{l c c c}
|
|
\toprule
|
|
\textbf{Target} &\textbf{Momentum} & \textbf{Run time} & \textbf{Number}\\
|
|
\textbf{and thickness}&\textbf{scaling factor} & \textbf{(h)} &\textbf{of muons}\\
|
|
\midrule
|
|
Si 1500 \micro\meter& 1.32& 3.07& $2.78\times 10^7$\\
|
|
& 1.30& 12.04& $2.89 \times 10^8$\\
|
|
& 1.10& 9.36& $1.37 \times 10^8$ \\
|
|
\midrule
|
|
Si 62 \micro\meter & 1.06& 10.29& $1.72 \times 10^8$\\
|
|
\midrule
|
|
Al 100 \micro\meter& 1.09& 14.37&$2.94 \times 10^8$\\
|
|
& 1.07& 2.56& $4.99 \times 10^7$\\
|
|
\midrule
|
|
Al 50 \micro\meter m & 1.07& 51.94& $8.81 \times 10^8$\\
|
|
\bottomrule
|
|
\end{tabular}
|
|
\end{center}
|
|
\caption{Run statistics. Momentum scaling
|
|
normalized to 28 MeV/c.}
|
|
\label{tb:stat}
|
|
\end{table}
|
|
|
|
% section data_sets (end)
|
|
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
|
|
\section{Analysis framework}
|
|
\subsection{Concept}
|
|
\label{sub:concept}
|
|
Since the AlCapDAQ is a trigger-less system, it stored all waveforms of the
|
|
hits occured in 100-ms-long blocks without considering their physics
|
|
significance The analysis code therefore must be able to extract parameters of
|
|
the waveforms, then organises the pulses into physics events correlated to
|
|
stopped muons (Figure~\ref{fig:muon_event}). In addition, the analyser is
|
|
intended to be usable as a real-time component of a MIDAS DAQ, where simple
|
|
analysis could be done online for monitoring and diagnostic during the run.
|
|
|
|
\begin{figure}[htb]
|
|
\centering
|
|
\includegraphics[width=0.9\textwidth]{figs/muon_event.pdf}
|
|
\caption{Concept of the AlCap analysis code: pulses from individual detector
|
|
in blocks of time are analysed, then sorted centred around stopped muons.}
|
|
\label{fig:muon_event}
|
|
\end{figure}
|
|
|
|
The analysis framework of the AlCap consists of two separate programs.
|
|
A MIDAS-based analyser framework, \alcapana{}, processes the raw data and
|
|
passes its ROOT data output to a second
|
|
stage, \rootana{}, where most of the physics analysis is performed.
|
|
Both programs were designed to be modularised, which allowed us to develop
|
|
lightweight analysis modules that were used online to generate plots quickly,
|
|
while more sophisticated modules can be applied in offline analysis.
|
|
|
|
The DAQ system generated MIDAS files which stores the data as a stream of MIDAS
|
|
``banks''. In the AlCapDAQ, each bank corresponds to a single channel on
|
|
a digitizer and was named according to a predefined convention. The map between
|
|
detector channels and MIDAS bank names was stored in the MIDAS online database
|
|
(ODB), along with other settings such as sampling frequencies, timing offsets,
|
|
thresholds and calibration coefficients of each channel.
|
|
%These can then be
|
|
%accessed by both \alcapana{} and \rootana{} for either online or offline
|
|
%analysis.
|
|
|
|
The first step
|
|
of the analysis framework is to convert the raw MIDAS data into waveforms,
|
|
series of digitised samples continuous in time corresponding to pulses from the
|
|
detector. The waveform is called \tpulseisland{}s, which contain the bank name,
|
|
the ADC values of the samples and the time stamp of the first sample. This
|
|
conversion is performed in \alcapana{} and the resulting objects are stored in
|
|
a ROOT output file as a {\ttfamily TTree}.
|
|
|
|
The next step of the analysis is to obtain summary parameters of the pulses
|
|
from the digitized samples. The parameters of primary interest are the
|
|
amplitude and time of the peak and the integral of the pulse. This extraction
|
|
of parameters is done by a \rootana{} module, and the objects produced by this
|
|
stage are called \tanalysedpulse{}s. Currently, we have a usable and simple
|
|
algorithm that takes the pulse parameters from the peak of the waveform. In
|
|
parallel, a pulse finding and template fitting code is being developed because
|
|
it would provide more accurate pulse information. The first iteration of this
|
|
code has been completed and is being tested.
|
|
\begin{figure}[htb]
|
|
\centering
|
|
\includegraphics[width=0.85\textwidth]{figs/analysis_scheme}
|
|
\caption{Concept of the analysis framework in \rootana{}}
|
|
\label{fig:rootana_scheme}
|
|
\end{figure}
|
|
|
|
After obtaining pulse parameters for individual channel, the pairing up of
|
|
fast and slow pulses from the same physical detector needs to be done. This
|
|
entails looping through all fast and slow pulses from each detector,
|
|
checking for correlated pulses in time and amplitude, creating
|
|
{\ttfamily TDetectorPulse}s. The {\ttfamily TDetectorPulse}s allow better
|
|
understanding of the hits on the detector by combining timing information from
|
|
the fast channel and amplitude information from the slow channel. It also helps
|
|
reduce the impact of pile-up on the amplitude measurement, where the
|
|
improved time resolution of the fast channels can be used to separate the
|
|
overlapping amplitudes in the slow channels. The pulse pairing are applicable to
|
|
the silicon and germanium channels only. The scintillator channels provide only
|
|
fast timing signals which can be used as {\ttfamily TDetectorPulse}s directly.
|
|
|
|
The detector pulses are subsequently used to identify particles that hit the
|
|
detectors. These particle hits are still stored in the time-ordered tree
|
|
corresponds to the 110 ms block length from the AlCapDAQ. By iterating through
|
|
the tree to find stopped muons and taking any hits within a certain window
|
|
around this muon from every detector, a stopped-muon-centred tree shown in
|
|
Figure~\ref{fig:muon_event} can be produced. This will make it much easier to
|
|
look for coincidences and apply cuts, thereby bringing the end
|
|
goal of particle numbers and energy distributions.
|
|
|
|
% subsection concept (end)
|
|
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
|
|
|
|
\subsection{Online analyser}
|
|
\label{sub:online_analyser}
|
|
The online analyser was developed and proved to be very useful during the run.
|
|
A few basic modules were used to produce plots for diagnostic purposes
|
|
including: persistency view of waveforms, pulse height
|
|
spectra, timing correlations with respect to the upstream counters. The
|
|
modules and their purposes are listed in Table~\ref{tab:online_modules}.
|
|
\begin{table}[htb]
|
|
\begin{center}
|
|
\begin{tabular}{l p{6cm}}
|
|
\toprule
|
|
\textbf{Module name} & \textbf{Functions}\\
|
|
\midrule
|
|
common/MUnCompressRawData & decompress raw MIDAS data\\
|
|
\midrule
|
|
FADC/MOctalFADCProcessRaw & \multirow{3}{6cm}{convert raw data to
|
|
{\ttfamily TPulseIsland}s}\\ v1724/MV1724ProcessRaw& \\
|
|
dt5720/MDT5720ProcessRaw&\\
|
|
\midrule
|
|
muSC\_muPC/MCaenCompProcessRaw& \multirow{4}{6cm}{decompress data from
|
|
{\ttfamily fe6}, make coincidence in upstream counters} \\
|
|
muSC\_muPC/MMuPC1AnalysisC&\\
|
|
muSC\_muPC/MMuPC1AnalysisMQL&\\
|
|
muSC\_muPC/MMuSCAnalysisMQL&\\
|
|
\midrule
|
|
diagnostics/MCommonOnlineDisplayPlots& produce plots of interest\\
|
|
\midrule
|
|
FADC/MOctalFADCBufferOverflow& \multirow{2}{6cm}{diagnostics for FADCs}\\
|
|
FADC/MOctalFADCPacketLoss&\\
|
|
\midrule
|
|
common/MExpectedIslands&\multirow{4}{6cm}{diagnostics in general}\\
|
|
common/MMuSCTimeDifferences&\\
|
|
common/MNumberIslands&\\
|
|
common/MPulseLengths&\\
|
|
\midrule
|
|
common/MTreeOutput& save {\ttfamily TPulseIsland}s tree\\
|
|
\bottomrule
|
|
\end{tabular}
|
|
\end{center}
|
|
\caption{Online analysis modules in the Run 2013.}
|
|
\label{tab:online_modules}
|
|
\end{table}
|
|
|
|
The \alcapana{} served the plots on port 9090 of the {\ttfamily abner}
|
|
via the ROOT socket protocol. We then used a ROOT-based program called
|
|
{\ttfamily online-display} to display the plots on the shift terminal
|
|
({\ttfamily alcap}). The {\ttfamily online-display} simply executed ROOT macros
|
|
which retrieved plots from the ROOT server, sorted then drew them in
|
|
groups such as upstream counters, silicon arms. It could also periodically
|
|
update the plots to reflect real-time status of the detector system.
|
|
%Screen
|
|
%shots of the {\ttfamily online-display} with several plots are shown in
|
|
%Figure~\ref{fig:online_display}.
|
|
|
|
%\hl{Screen shots}
|
|
\subsection{Offline analyser}
|
|
\label{sub:offline_analyser}
|
|
Some offline analysis modules has been developed during the beam time and could
|
|
provide quick feedback in confirming and guiding the decisions at the time. For
|
|
example, the X-ray spectrum analysis was done to confirm that we could observe
|
|
the muon capture process (Figure~\ref{fig:muX}), and to help in choosing optimal
|
|
momenta which maximised the number of stopped muons.
|
|
\begin{figure}[htbp]
|
|
\centering
|
|
\includegraphics[width=0.7\textwidth]{figs/muX.png}
|
|
\caption{Germanium
|
|
detector spectra in the range of 300 - 450 keV with different setups: no
|
|
target, 62-\micron-thick silicon target, and 100-\micron-thick aluminium
|
|
target. The ($2p-1s$) lines from
|
|
aluminium (346.828 keV) and silicon (400.177 keV) are clearly visible,
|
|
the double peaks at 431 and 438 keV are from the lead shield, the peak at
|
|
351~keV is a background gamma ray from $^{211}$Bi.}
|
|
\label{fig:muX}
|
|
\end{figure}
|
|
|
|
Although the offline analyser is still not fully developed yet, several modules
|
|
are ready. They are described in detailed in the next chapter.
|
|
% subsection offline_analyser (end)
|
|
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
|
|
% section analysis_strategy (end)
|
|
|
|
|
|
% chapter the_alcap_run_2013 (end)
|
|
|