The AlCap 2013 run demonstrated that the setup was capable of
|
||||
performing this demanding charged particle experiment and led to
|
||||
preliminary results. In R2015 we plan to improve several aspects which
|
||||
will reduce the systematic uncertainty and improve the quality of the
|
||||
final result.
|
||||
|
||||
\begin{itemize}
|
||||
|
||||
\item
|
||||
\textbf{Beam profile measurements at target location.}
|
||||
We intend to assemble a small probe
|
||||
which can be inserted to measure the beam profile at the target
|
||||
position for all measurements. Two possible methods are under
|
||||
consideration: the first uses a series of crossed scintillating fibres
|
||||
read-out with MPPCs, the second uses a single fibre which is scanned
|
||||
across the beam.
|
||||
|
||||
\item
|
||||
\textbf{Beam and detector geometry in the vacuum chamber.} We plan an
|
||||
improved mechanics and surveying method for determining the relative
|
||||
target and detector positions.
|
||||
|
||||
\item
|
||||
\textbf{Improved silicon detector frontend.} We plan to suppress noise
|
||||
and increase the stability of the Si detector readout, by placing
|
||||
the preamplifiers inside the vacuum chamber. In addition, the shaping
|
||||
constants of the fast preamplier outputs were not optimised, which
|
||||
led to significant noise or undershoots in those signals.
|
||||
|
||||
\item
|
||||
\textbf{DAQ.} The FADCs experienced data losses in high rate situations,
|
||||
e.g. when using the silicon detector as active target. This data
|
||||
quality issue will be eliminated by purchasing, and carefully
|
||||
testing, new wave form digitisers from CAEN or SIS.
|
||||
|
||||
\item
|
||||
\textbf{Ge detector.} The time resolution of the Ge detector was
|
||||
only 66 ns FWHM, larger than specified (10 ns). This problem will addressed
|
||||
with careful comparisons of analogue and digitised readout chains in our university labs.
|
||||
|
||||
\end{itemize}
|
||||
|
||||