chap8
This commit is contained in:
31
thesis/chapters/chap8_conclusions.tex
Normal file
31
thesis/chapters/chap8_conclusions.tex
Normal file
@@ -0,0 +1,31 @@
|
|||||||
|
\chapter{Conclusions}
|
||||||
|
\label{cha:conclusions}
|
||||||
|
AlCap is an experiment proposed at PSI to study charged particles, neutrons
|
||||||
|
and photons emitting after nuclear muon capture on aluminium. These
|
||||||
|
measurements are important for backgrounds and hit rates estimation of the new
|
||||||
|
generation of \mueconv experiments, COMET and Mu2e. In the first stage of the
|
||||||
|
COMET experiment, hit rate on its main tracking detector is anticipated to be
|
||||||
|
dominated by low energy protons following muon capture on an aluminium target,
|
||||||
|
which has never been measured.
|
||||||
|
|
||||||
|
The first run of the AlCap which aims for proton measurement has been carried
|
||||||
|
out in 2013. Data analysis is in progress. An initial analysis on partial data
|
||||||
|
was done with the main results are:
|
||||||
|
\begin{enumerate}
|
||||||
|
\item Demonstration of the analysis chain from raw waveforms to physics
|
||||||
|
events;
|
||||||
|
\item Validation of the experimental method including: number of nuclear
|
||||||
|
capture muons normalisation by muonic X-ray measurement, charged particle
|
||||||
|
identification by specific energy loss, and unfolding of the proton energy
|
||||||
|
spectrum using the iterative Bayesian method;
|
||||||
|
\item Obtaining preliminary results on proton emission rate and spectrum:
|
||||||
|
the proton spectrum has a peak at \SI{4}{\MeV}, then reduces exponentially
|
||||||
|
with a decay constant of \SI{2.6}{\MeV}. The partial emission rate in the
|
||||||
|
energy range from \SIrange{4}{8}{\MeV} is $(1.7 \pm 0.1)\%$, and the total
|
||||||
|
emission rate assuming the shape holds for the whole spectrum is
|
||||||
|
$(3.5\pm0.2)$.
|
||||||
|
\end{enumerate}
|
||||||
|
The proton rate and spectrum have been used to optimise the planned proton
|
||||||
|
absorber for the drift chamber of the COMET Phase-I. The resulted proton hit
|
||||||
|
rate with the baseline configuration is very small compared with the current
|
||||||
|
figure. It is safe to remove the proton absorber altogether.
|
||||||