first draft r15a xray

This commit is contained in:
2019-05-27 10:17:38 +02:00
parent 829e20df91
commit 4bd2bbbbf5
6 changed files with 226 additions and 14 deletions

Binary file not shown.

Before

Width:  |  Height:  |  Size: 1.1 MiB

After

Width:  |  Height:  |  Size: 616 KiB

View File

@@ -1,2 +1,146 @@
\section{Data analysis} \section{Data analysis}
\subsection{Digital pulse processing}
\label{sub:digital_pulse_processing}
Since we recorded all detector outputs using digitizers, offline digital pulse
processing is needed to extract energy and timing information. Typical output
pulses from HPGe and \ce{LaBr3} detectors are shown in
\cref{fig:typical_pulses}.
\begin{center}
\begin{figure}[tbp]
\centering
\includegraphics[width=1.0\textwidth]{figs/typical_pulses}
\caption{Typical output pulses of HPGe and \ce{LaBr3} detectors: energy
output HPGe high gain (top left), energy output HPGe low gain (top
right), timing output HPGe (bottom left), and \ce{LaBr3} (bottom right).
Each clock tick corresponds to \SI{10}{\ns} and \SI{2}{\ns} for top and
bottom plots, respectively.}
\label{fig:typical_pulses}
\end{figure}
\end{center}
The timing pulses from the HPGe detector were not used in this analysis because
they are too long and noisy (see bottom left \cref{fig:typical_pulses}).
Energy of the HPGe detector is taken as amplitude of spectroscopy amplifier
outputs, its timing is determined by the clock tick where the trace passes
\SI{30}{\percent} of the amplitude. The timing resolution is \SI{235}{\ns}
using this method.
\subsection{Calibrations}
\label{sub:calibrations}
The HPGe detector energy scales and acceptance were calibrated
using \ce{^{152}Eu}, \ce{^{60}Co}, \ce{^{88}Y} sources placed at the target
position. There was a separate run for background radiation.
Energy resolutions are better than \SI{3.2}{\keV} for all calibrated peaks.
\begin{center}
\begin{figure}[htbp]
\centering
\includegraphics[width=1.0\textwidth]{figs/hpge_ecal}
\caption{Energy calibration spectra for the HPGe detector.}
\label{fig:hpge_ecal}
\end{figure}
\end{center}
The detector acceptance above \SI{200}{\kilo\eV} were fitted using an empirical
function:
\begin{equation}
A = c_1 \times E ^ {c_2},
\end{equation}
where $c_1 = 0.1631$, $c_2 = -0.9257$, and $E$ is photon energy in \si{\keV}.
Interpolation gives detector acceptance at the peaks of interest as shown in
\cref{tab:hpge_acceptance}.
\begin{center}
\begin{figure}[htbp]
\centering
\includegraphics[width=1.0\textwidth]{figs/hpge_higain_acceptance}
\caption{Acceptance of the HPGe as a function of photon energy.}
\label{fig:hpge_higain_acceptance}
\end{figure}
\end{center}
\begin{table}[tbp]
\centering
\caption{HPGe acceptance for photons of interest}
\label{tab:hpge_acceptance}
\begin{tabular}{@{}cccc@{}}
\toprule
\multicolumn{2}{c}{\textbf{\begin{tabular}[c]{@{}c@{}}Photon energy\\ {[}keV{]}\end{tabular}}} & \textbf{Acceptance} & \textbf{Error} \\
\midrule
$2p-1s$ & 346.8 & \num{8.75E-4} &\num{4.0e-5} \\
\ce{^{27}Mg} & 843.7 & \num{3.40E-4} &\num{0.9e-5} \\
% & 1014.4 & \num{2.69e-4} &\num{1.07e-5} \\
\ce{^{nat}Ti} & 931.96 & \num{3.06E-4} &\num{0.8e-5} \\
\ce{^{26}Mg}* & 1088.7 & \num{1.51e-4} &\num{0.7e-5} \\
% 0 346.828 0.000875 0.000040
% 1 399.268 0.000753 0.000030
% 2 400.177 0.000751 0.000030
% 3 476.800 0.000624 0.000022
% 4 843.740 0.000340 0.000009
% 5 930.000 0.000306 0.000008
% 6 931.000 0.000306 0.000008
% 7 932.000 0.000306 0.000008
% 8 1014.420 0.000279 0.000008
% 9 1808.660 0.000151 0.000007
\bottomrule
\end{tabular}
\end{table}
\subsection{Number of stopped muons}
% TODO: justification for taking just number from muon counter
The number of stopped muons are taken as number of muons seen by the muon
counter, since we used thick targets the muon beam is believed to stop
completely at the middle of the targets. This assumption is verified for the
aluminum target where count from muon counter was consistent with number of
stopped muons calculated from number of $(2p-1s)$ X-rays.
\subsection{Muonic X-ray spectra}
We use the HPGe spectra to look for characteristic muonic X-rays from elements
of interest. Energies of these muonic X-rays are listed
in~\cref{tab:hpge_acceptance}.
\subsubsection{Titanium}
We are looking at X-rays from $(2p-1s)$ transitions in titanium. Natural
titanium has 5 stable isotopes: \ce{^{46}Ti}, \ce{^{47}Ti}, \ce{^{48}Ti},
\ce{^{49}Ti}, and \ce{^{50}Ti}, with the \ce{^{48}Ti} being the
most abundant at 73.72\%. The fine splitting between muonic $2p_{3/2}
$ and $2p_{1/2}$ levels in these stable isotopes are about
\SI{2}{keV}~\cite{Wohlfahrt1981}, comparable to the resolution of our HPGe
detector. The $(2p-1s)$ X-rays therefore show up as a broad, asymmetric peak
with a longer tail on the low energy side. The peak is fitted as two
Gaussian peaks on top of a first-order polynomial.
\subsection{Fraction of muon captured by a nucleus}
An atomic captured muon at the 1S state has only two choices, either to decay
in orbit or to be captured on the nucleus. The total disappearance rate for
negative muon, $\Lambda_{tot}$, is given by:
\begin{equation}
\Lambda_{tot} = \Lambda_{cap} + Q \Lambda_{free},
\label{eq:mu_total_capture_rate}
\end{equation}
where $\Lambda_{cap}$ and $\Lambda_{free}$ are nuclear capture rate and free
decay rate, respectively, and $Q$ is the Huff factor, which is corrects for the
fact that muon decay rate in a bound state is reduced because of the binding
energy reduces the available energy.
Using mean lifetime measured by Suzuki et.al.~\cite{SuzukiMeasday.etal.1987}
and fractions of muons captured by element of interest are calculated and
listed in~\cref{tab:capture_frac}.
\begin{table}[tbp]
\centering
\caption{Nuclear capture probability calculated from mean lifetimes taken
from measurements of Suzuki et.al.~\cite{SuzukiMeasday.etal.1987}}
\label{tab:capture_frac}
\begin{tabular}{cccc}
\toprule
Element & Mean lifetime & Huff factor & Nuclear capture\\
& [\si{ns}] & & probability [\%]\\
\midrule
\ce{^{nat}Al} & \num{864.0 \pm 1.0} & \num{0.993} &\num{60.95(5)} \\
\ce{^{nat}Ti} & \num{329.3 \pm 1.3} & \num{0.981} &\num{85.29(6)} \\
\ce{^{nat}W} & \num{78.4 \pm 1.5} & \num{0.860} &\num{96.93(6)} \\
\bottomrule
\end{tabular}
\end{table}

View File

@@ -1,2 +1,11 @@
\section{Introduction} \section{Introduction}
Why are we even doing this measurement? Here is a very thorough study~\cite{Zinatulina2019} Why are we even doing this measurement?
\begin{itemize}
\item targets for mu-e conversion experiments
\item why did we measure \ce{W}, \ce{H_2O}, \ldots: background for Xrays of
interest in Mu2e
\item existing data? focused on nuclear charge radii, did not report muonic
X-ray yields. This is true for \ce{^{nat}Ti}~\cite{Wohlfahrt1981}
\end{itemize}

View File

@@ -1,2 +1,28 @@
\section{Results and discussions} \section{Results and discussions}
\subsection{Titanium}
Number of stopped muons in the natural titanium target was:
\begin{equation}
N_{\mu} = (88296 \pm 9) \times 10^3 \,.
\label{eqn:Nmu_Ti_Tsc}
\end{equation}
Fitting the peak around \SI{931}{keV} in the photon spectrum gives the
center of gravity at \SI{931.6 \pm 0.7}{keV} (see~\cref{fig:ti_931keV_fit}),
consistent with previously reported value~\cite{Wohlfahrt1981}.
Number of $(2p-1s)$ X-rays in the \SI{931.6}{keV} peak is:
\begin{equation}
N_{931.6} = (20750 \pm 764) \,.
\end{equation}
\begin{figure}[tbp]
\centering
\includegraphics[width=0.8\textwidth]{figs/ti_931keV_fit}
\caption{Fitting $(2p-1s)$ peaks}
\label{fig:ti_931keV_fit}
\end{figure}
The emission rate of the $(2p-1s)$ muonic X-rays is calculated as:
\begin{equation}
R_{Ti} = \frac{N_{931.6}}{A_{931.6} \times N_{\mu} \times f_{capTi}} = 0.90
\pm 0.04 \,.
\end{equation}

View File

@@ -5,14 +5,14 @@ The 2015 summer run focused on the detection of neutral particles: low energy
X-ray, gamma ray and neutron emission after the muon is captured by the X-ray, gamma ray and neutron emission after the muon is captured by the
nucleus. nucleus.
The X-rays and gamma rays of interest are: % The X-rays and gamma rays of interest are:
\begin{itemize} % \begin{itemize}
\item muonic $2p-1s$ transition in aluminum: \SI{346.8}{\kilo\eV} % \item muonic $2p-1s$ transition in aluminum: \SI{346.8}{\kilo\eV}
\item \SI{843.7}{\kilo\eV} gamma from the $\beta^-$ decay of \ce{^{27}Mg} % \item \SI{843.7}{\kilo\eV} gamma from the $\beta^-$ decay of \ce{^{27}Mg}
(half-life: \SI{9.46}{\min}) % (half-life: \SI{9.46}{\min})
\item \SI{1808.7}{\kilo\eV} gamma from the first excited state of % \item \SI{1808.7}{\kilo\eV} gamma from the first excited state of
\ce{^{26}Mg} % \ce{^{26}Mg}
\end{itemize} % \end{itemize}
Low momentum muons (less than \SI[]{40}{\mega\eVperc}) were stopped in Low momentum muons (less than \SI[]{40}{\mega\eVperc}) were stopped in
a target after passing a muon counter a target after passing a muon counter
@@ -58,11 +58,16 @@ Experimental layout is shown in \cref{fig:R2015a_setup}.
\begin{center} \begin{center}
\begin{figure}[tbp] \begin{figure}[tbp]
\centering \centering
\includegraphics[width=0.70\textwidth]{figs/r15a_setup_photo} \begin{minipage}{0.45\textwidth}
\caption{Layout of the AlCap 2015 summer run. Muons entered from the top of \includegraphics[width=1.0\textwidth]{figs/r15a_setup_photo}
the image. The LYSO detector is not visible in this image, which is \end{minipage}
located further out in the bottom of the image.} \begin{minipage}{0.45\textwidth}
\label{fig:R2015a_setup} \includegraphics[width=1.0\textwidth]{figs/alcap_r15a_setup}
\end{minipage}
\caption{Layout of the AlCap experiment in the summer 2015 run. Negative
muons entered from the top of the photo. The LYSO detector is not visible
in this image, which is located further out in the bottom of the image.}
\label{fig:r15a_setup}
\end{figure} \end{figure}
\end{center} \end{center}
@@ -70,4 +75,6 @@ There were several runs with different targets made of aluminum, titanium,
lead, water. All targets were sufficiently thick to stop the muon beam with lead, water. All targets were sufficiently thick to stop the muon beam with
momenta up to \SI{40}{\mega\eVperc}. momenta up to \SI{40}{\mega\eVperc}.
TODO: a table of targets and details

View File

@@ -30,6 +30,32 @@
url = {https://link.aps.org/doi/10.1103/PhysRevC.23.533}, url = {https://link.aps.org/doi/10.1103/PhysRevC.23.533},
} }
@Article{SuzukiMeasday.etal.1987,
author = {Suzuki, T and Measday, David F and Roalsvig, JP},
title = {Total nuclear capture rates for negative muons},
journal = {Physical Review C},
year = {1987},
volume = {35},
number = {6},
pages = {2212},
file = {Published version:SuzukiMeasday.etal.1987.pdf:PDF},
owner = {NT},
publisher = {APS},
timestamp = {2014-07-13},
url = {http://journals.aps.org/prc/abstract/10.1103/PhysRevC.35.2212},
}
@Article{refId0,
author = {{Zinatulina, Daniya} and {Brian\c{c}on, Chantal} and {Brudanin, Victor} and {Egorov, Viacheslav} and {Perevoshchikov, Lev} and {Shirchenko, Mark} and {Yutlandov, Igor} and {Petitjean, Claude}},
title = {Electronic catalogue of muonic X-rays},
journal = {EPJ Web Conf.},
year = {2018},
volume = {177},
pages = {03006},
doi = {10.1051/epjconf/201817703006},
url = {https://doi.org/10.1051/epjconf/201817703006},
}
@Comment{jabref-meta: databaseType:bibtex;} @Comment{jabref-meta: databaseType:bibtex;}
@Comment{jabref-meta: grouping: @Comment{jabref-meta: grouping: