Merge branch 'feature/thesis'
This commit is contained in:
BIN
AlCapPSI/draft/.DS_Store
vendored
BIN
AlCapPSI/draft/.DS_Store
vendored
Binary file not shown.
@@ -5,7 +5,7 @@ TARGET= $(DOCNAME).pdf
|
|||||||
|
|
||||||
default: $(TARGET)
|
default: $(TARGET)
|
||||||
|
|
||||||
$(TARGET): $(INPUT) Makefile chapters/*.tex custom_macro.tex mythesis.sty
|
$(TARGET): $(INPUT) Makefile chapters/*.tex custom_macro.tex mythesis.sty raw/*
|
||||||
@rm -f $(DOCNAME).{aux,toc,lof,lot}
|
@rm -f $(DOCNAME).{aux,toc,lof,lot}
|
||||||
pdflatex $< && bibtex $(DOCNAME) && pdflatex $< && pdflatex $<
|
pdflatex $< && bibtex $(DOCNAME) && pdflatex $< && pdflatex $<
|
||||||
|
|
||||||
|
|||||||
@@ -58,15 +58,18 @@ observation of CLFV would be a clear signal of new physics beyond the SM.
|
|||||||
|
|
||||||
The COMET (\textbf{CO}herent \textbf{M}uon to \textbf{E}lectron
|
The COMET (\textbf{CO}herent \textbf{M}uon to \textbf{E}lectron
|
||||||
\textbf{T}ransition) Collaboration aims to probe the conversion of a muon to
|
\textbf{T}ransition) Collaboration aims to probe the conversion of a muon to
|
||||||
an electron in a nucleus field at a sensitivity of $6\times10^{-17}$, pushing
|
an electron in a nucleus field at a single event sensitivity of \num{6E-17},
|
||||||
for a four orders of magnitude improvement from the current limit set by the
|
pushing for a four orders of magnitude improvement from the current limit set
|
||||||
|
by the
|
||||||
SINDRUM-II~\cite{Bertl.etal.2006}. A staging approach is adopted at the COMET
|
SINDRUM-II~\cite{Bertl.etal.2006}. A staging approach is adopted at the COMET
|
||||||
to achieve an intermediate physics result, as well as to gain operational
|
to achieve an intermediate physics result, as well as to gain operational
|
||||||
experience. The first stage, COMET Phase I, is scheduled to start in 2016 with
|
experience. The first stage, COMET Phase I, is scheduled to start data taking
|
||||||
the goal sensitivity of $3\times 10^{-15}$ after a three-month-running period.
|
in 2016 with the goal single event sensitivity of $3.1\times 10^{-15}$ after
|
||||||
|
a three-month running period.
|
||||||
|
|
||||||
A cylindrical drift chamber being developed by the Osaka University group
|
A cylindrical drift chamber being developed by the Osaka University group
|
||||||
will be the main tracking detector in the COMET Phase I. It is anticipated that
|
together with the Kyushu University group and the Chinese groups
|
||||||
|
will be a main tracking detector in the COMET Phase I. It is anticipated that
|
||||||
the chamber will be heavily occupied by protons emitted after nuclear muon
|
the chamber will be heavily occupied by protons emitted after nuclear muon
|
||||||
capture in the stopping target, and thus an absorber will be installed to
|
capture in the stopping target, and thus an absorber will be installed to
|
||||||
reduce the proton hit rate to a tolerable level. A study of proton emission
|
reduce the proton hit rate to a tolerable level. A study of proton emission
|
||||||
@@ -83,6 +86,6 @@ sensitivities. Details of the study on proton emission are described in
|
|||||||
Chapters~\ref{cha:alcap_phys},~\ref{cha:the_alcap_run_2013},~\ref{cha:data_analysis}:
|
Chapters~\ref{cha:alcap_phys},~\ref{cha:the_alcap_run_2013},~\ref{cha:data_analysis}:
|
||||||
physics, method, experimental set up, data analysis. The results and impacts of
|
physics, method, experimental set up, data analysis. The results and impacts of
|
||||||
the study on COMET Phase-I design is discussed in
|
the study on COMET Phase-I design is discussed in
|
||||||
Chapter~\ref{cha:discussions}.
|
Chapter~\ref{cha:discussions_on_the_impact_to_the_comet_phase_i}.
|
||||||
|
|
||||||
% chapter introduction (end)
|
% chapter introduction (end)
|
||||||
|
|||||||
@@ -1,7 +1,49 @@
|
|||||||
\chapter{Lepton flavour and $\mu-e$ conversion}
|
\chapter{Overview}
|
||||||
\thispagestyle{empty}
|
\thispagestyle{empty}
|
||||||
\label{cha:clfv}
|
\label{cha:clfv}
|
||||||
|
|
||||||
|
\section{Introduction}
|
||||||
|
\label{sec:introduction}
|
||||||
|
The COMET experiment~\cite{COMET.2007}, proposed at the Japan Proton
|
||||||
|
Accelerator Research Complex (J-PARC), is a next-generation-experiment that
|
||||||
|
searches for evidence of charged lepton flavour violation (CLFV) with muons.
|
||||||
|
The branching ratio of CLFV in the Standard Model, even with massive neutrinos,
|
||||||
|
is prohibitively small, at the order of $10^{-54}$. Therefore, any experimental
|
||||||
|
observation of CLFV would be a clear signal of new physics beyond the SM.
|
||||||
|
|
||||||
|
The COMET (\textbf{CO}herent \textbf{M}uon to \textbf{E}lectron
|
||||||
|
\textbf{T}ransition) Collaboration aims to probe the conversion of a muon to
|
||||||
|
an electron in a nucleus field at a single event sensitivity of \num{6E-17},
|
||||||
|
pushing for a four orders of magnitude improvement from the current limit set
|
||||||
|
by the
|
||||||
|
SINDRUM-II~\cite{Bertl.etal.2006}. A staging approach is adopted at the COMET
|
||||||
|
to achieve an intermediate physics result, as well as to gain operational
|
||||||
|
experience. The first stage, COMET Phase I, is scheduled to start data taking
|
||||||
|
in 2016 with the goal single event sensitivity of $3\times 10^{-15}$ after
|
||||||
|
a three-month running period.
|
||||||
|
|
||||||
|
A cylindrical drift chamber being developed by the Osaka University group
|
||||||
|
together with the Kyushu University group and the Chinese groups
|
||||||
|
will be a main tracking detector in the COMET Phase I. It is anticipated that
|
||||||
|
the chamber will be heavily occupied by protons emitted after nuclear muon
|
||||||
|
capture in the stopping target, and thus an absorber will be installed to
|
||||||
|
reduce the proton hit rate to a tolerable level. A study of proton emission
|
||||||
|
following nuclear muon capture for optimisation of the proton absorber is
|
||||||
|
presented in this thesis.
|
||||||
|
|
||||||
|
The thesis is structured as follows:
|
||||||
|
firstly,
|
||||||
|
the physics motivation of the COMET experiment, with muon's normal decays and
|
||||||
|
CLFV decays, is described in this later part of this chapter.
|
||||||
|
Chapter~\ref{cha:comet_overview} gives an overview of the
|
||||||
|
COMET experiment: beam lines, detectors and their requirements, and expected
|
||||||
|
sensitivities. Details of the study on proton emission are described in
|
||||||
|
Chapters~\ref{cha:alcap_phys},~\ref{cha:the_alcap_run_2013},~\ref{cha:data_analysis}:
|
||||||
|
physics, method, experimental set up, data analysis. The results and impacts of
|
||||||
|
the study on COMET Phase-I design is discussed in
|
||||||
|
Chapter~\ref{cha:discussions_on_the_impact_to_the_comet_phase_i}.
|
||||||
|
|
||||||
|
|
||||||
\section{Lepton flavour}
|
\section{Lepton flavour}
|
||||||
\label{sec:lepton_flavour}
|
\label{sec:lepton_flavour}
|
||||||
According to the SM, all matter is built from a small set of fundamental
|
According to the SM, all matter is built from a small set of fundamental
|
||||||
@@ -9,7 +51,7 @@ spin one-half particles, called fermions: six quarks and six leptons.
|
|||||||
The six leptons form three generations (or flavours), namely:
|
The six leptons form three generations (or flavours), namely:
|
||||||
\begin{equation*}
|
\begin{equation*}
|
||||||
\binom{\nu_e}{e^-}, \quad \binom{\nu_\mu}{\mu^-} \quad \textrm{ and } \quad
|
\binom{\nu_e}{e^-}, \quad \binom{\nu_\mu}{\mu^-} \quad \textrm{ and } \quad
|
||||||
\binom{\nu_\tau}{\tau^-}
|
\binom{\nu_\tau}{\tau^-}.
|
||||||
\end{equation*}
|
\end{equation*}
|
||||||
|
|
||||||
Each lepton is assigned a lepton flavour quantum number, $L_e$, $L_\mu$,
|
Each lepton is assigned a lepton flavour quantum number, $L_e$, $L_\mu$,
|
||||||
@@ -24,7 +66,7 @@ or, the interaction of an electron-type antineutrino with a proton (inverse
|
|||||||
beta decay):
|
beta decay):
|
||||||
\begin{align*}
|
\begin{align*}
|
||||||
&\quad \overline{\nu}_e + p \rightarrow e^+ + n \\
|
&\quad \overline{\nu}_e + p \rightarrow e^+ + n \\
|
||||||
L_e \quad &-1 \quad \textrm{ }0 \quad -1 \textrm{ } \quad 0
|
L_e \quad &-1 \quad \textrm{ }0 \quad -1 \textrm{ } \quad 0
|
||||||
\end{align*}
|
\end{align*}
|
||||||
|
|
||||||
The decay of a muon to an electron and a photon, where lepton flavour numbers
|
The decay of a muon to an electron and a photon, where lepton flavour numbers
|
||||||
@@ -40,15 +82,25 @@ are violated by one unit or more, is forbidden:
|
|||||||
\end{aligned}
|
\end{aligned}
|
||||||
\label{eq:mueg}
|
\label{eq:mueg}
|
||||||
\end{equation}
|
\end{equation}
|
||||||
|
|
||||||
|
However, it is observed that neutrinos do change flavour in the so-called
|
||||||
|
neutrino oscillations where a neutrino of a certain lepton flavour
|
||||||
|
can be measured to have a different flavour as it travels in space-time. The
|
||||||
|
phenomenon has been confirmed in many experiments with solar neutrinos,
|
||||||
|
atmospheric neutrinos, reactor neutrinos and beam neutrinos. The observation
|
||||||
|
of neutrino oscillations means that the lepton flavour is not strictly
|
||||||
|
conserved and neutrinos are massive. The massive neutrinos allow lepton
|
||||||
|
flavour violation in the charged leptons, but at an unmeasurably small level
|
||||||
|
as described in \cref{sec:lepton_flavour_violation}.
|
||||||
%One more decay?
|
%One more decay?
|
||||||
|
|
||||||
%\hl{TODO: Why massless neutrinos help lepton flavour conservation??}
|
%\hl{TODO: Why massless neutrinos help lepton flavour conservation??}
|
||||||
%\hl{TODO: copied from KunoOkada}
|
%\hl{TODO: copied from KunoOkada}
|
||||||
%In the minimal version of the SM, where only one Higgs doublet is included and
|
%In the minimal version of the SM, where only one Higgs doublet is included and
|
||||||
%massless neutrinos are assumed, lepton flavor conservation is an automatic
|
%massless neutrinos are assumed, lepton conservation is an automatic
|
||||||
%consequence of gauge invariance and the renormalizability of the SM
|
%consequence of gauge invariance and the renormalizability of the SM
|
||||||
%Lagrangian. It is the basis of a natural explanation for the smallness of
|
%Lagrangian. It is the basis of a natural explanation for the smallness of
|
||||||
%lepton flavor violation (LFV) in charged lepton processes.
|
%lepton violation (LFV) in charged lepton processes.
|
||||||
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
|
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
|
||||||
|
|
||||||
\section{Muon and its decays in the Standard Model}
|
\section{Muon and its decays in the Standard Model}
|
||||||
@@ -111,15 +163,15 @@ or with an associated $e^+ e^-$ pair:
|
|||||||
\label{eq:mu3e2nu}
|
\label{eq:mu3e2nu}
|
||||||
\end{equation}
|
\end{equation}
|
||||||
|
|
||||||
The dominant process, \micheldecay is commonly called Michel decay. It can be
|
The dominant process, \micheldecay is commonly called the Michel decay. It can
|
||||||
described by the V-A interaction which is a special case of a local,
|
be described by the V-A interaction which is a special case of a local,
|
||||||
derivative-free, lepton-number-conserving four-fermion interaction.
|
derivative-free, lepton-number-conserving four-fermion interaction.
|
||||||
%using $V-A$
|
%using $V-A$
|
||||||
%inteaction, a special case of four-fermion interaction, by Louis
|
%inteaction, a special case of four-fermion interaction, by Louis
|
||||||
%Michel~\cite{Michel.1950}.
|
%Michel~\cite{Michel.1950}.
|
||||||
The model contains independent real parameters that can be determined from
|
The model contains independent real parameters that can be determined from
|
||||||
measurements of muon life time, muon decay and inverse muon
|
measurements of muon life time, muon decay and inverse muon
|
||||||
decay. Experimental results from extensive measurements of Michel parameters
|
decay. Experimental results from extensive measurements of the Michel parameters
|
||||||
are consistent with the predictions of the V-A
|
are consistent with the predictions of the V-A
|
||||||
theory~\cite{Michel.1950,FetscherGerber.etal.1986,BeringerArguin.etal.2012}.
|
theory~\cite{Michel.1950,FetscherGerber.etal.1986,BeringerArguin.etal.2012}.
|
||||||
|
|
||||||
@@ -127,9 +179,9 @@ The radiative decay~\eqref{eq:mue2nugamma} is treated as an internal
|
|||||||
bremsstrahlung process~\cite{EcksteinPratt.1959}.
|
bremsstrahlung process~\cite{EcksteinPratt.1959}.
|
||||||
%It occurs at the rate of about 1\% of all muon decays.
|
%It occurs at the rate of about 1\% of all muon decays.
|
||||||
Since it is not possible to clearly separated this mode
|
Since it is not possible to clearly separated this mode
|
||||||
from Michel decay in the soft-photon limit, the radiative mode is regarded as
|
from the Michel decay in the soft-photon limit, the radiative mode is regarded as
|
||||||
a subset of the Michel decay. An additional parameter is included to describe
|
a subset of the Michel decay. An additional parameter is included to describe
|
||||||
the electron and photon spectra in this decay channel. Like the case of
|
the electron and photon spectra in this decay channel. Like the case of the
|
||||||
Michel decay, experiments results on the branching ratio and the parameter are
|
Michel decay, experiments results on the branching ratio and the parameter are
|
||||||
in agreement with the SM's predictions~\cite{BeringerArguin.etal.2012}.
|
in agreement with the SM's predictions~\cite{BeringerArguin.etal.2012}.
|
||||||
|
|
||||||
@@ -198,7 +250,7 @@ flavour was experimentally verified in the Nobel Prize-winning experiment of
|
|||||||
Danby et al. at Brookhaven National Laboratory
|
Danby et al. at Brookhaven National Laboratory
|
||||||
(BNL)~\cite{DanbyGaillard.etal.1962}. Then the concepts of generations of
|
(BNL)~\cite{DanbyGaillard.etal.1962}. Then the concepts of generations of
|
||||||
particles was developed~\cite{MakiNakagawa.etal.1962}, and integrated into the
|
particles was developed~\cite{MakiNakagawa.etal.1962}, and integrated into the
|
||||||
SM, in which the lepton flavour conservation is guaranteed by and exact
|
SM, in which the lepton flavour conservation is guaranteed by an exact
|
||||||
symmetry, owing to massless neutrinos.
|
symmetry, owing to massless neutrinos.
|
||||||
|
|
||||||
Following the above LFV searches with muons, searches with various particles,
|
Following the above LFV searches with muons, searches with various particles,
|
||||||
@@ -215,14 +267,14 @@ must be modified to accommodate the massive neutrinos.
|
|||||||
With the massive neutrinos charged lepton flavour violation (CLFV) must occur
|
With the massive neutrinos charged lepton flavour violation (CLFV) must occur
|
||||||
through oscillations in loops. But, CLFV processes are highly suppressed in the
|
through oscillations in loops. But, CLFV processes are highly suppressed in the
|
||||||
SM.
|
SM.
|
||||||
For example, Marciano and Mori ~\cite{MarcianoMori.etal.2008} calculated the
|
%\hl{TODO: Feynman diagram}
|
||||||
|
For example, Marciano and Mori~\cite{MarcianoMori.etal.2008} calculated the
|
||||||
branching ratio of the process \mueg to be \brmeg$<10^{-54}$. Other
|
branching ratio of the process \mueg to be \brmeg$<10^{-54}$. Other
|
||||||
CLFV processes with muons are also suppressed to similar practically
|
CLFV processes with muons are also suppressed to similar practically
|
||||||
unmeasurable levels.%\hl{TODO: Feynman diagram}
|
unmeasurable levels. Therefore, any experimental
|
||||||
Therefore, any experimental
|
|
||||||
observation of CLFV would be an unambiguous signal of the physics beyond the
|
observation of CLFV would be an unambiguous signal of the physics beyond the
|
||||||
SM. Many models for physics beyond the SM, including supersymmetric (SUSY)
|
SM. Many theoretical models for physics beyond the SM, including supersymmetric
|
||||||
models, extra dimensional models, little Higgs models, predict
|
(SUSY) models, extra dimensional models, little Higgs models, predict
|
||||||
significantly larger CLFV
|
significantly larger CLFV
|
||||||
~\cite{MarcianoMori.etal.2008, MiharaMiller.etal.2013, BernsteinCooper.2013}.
|
~\cite{MarcianoMori.etal.2008, MiharaMiller.etal.2013, BernsteinCooper.2013}.
|
||||||
%\hl{TODO: DNA of CLFV charts}
|
%\hl{TODO: DNA of CLFV charts}
|
||||||
@@ -256,16 +308,16 @@ significantly larger CLFV
|
|||||||
%It is calculated that there are two CLFV processes that would
|
%It is calculated that there are two CLFV processes that would
|
||||||
%occur at large rates by many new physics models,
|
%occur at large rates by many new physics models,
|
||||||
Among the CLFV processes, the \mueg and
|
Among the CLFV processes, the \mueg and
|
||||||
the \muec are expected to have large effect by many models. The current
|
the \muec are expected to have large effect in many models. The current
|
||||||
experimental limits on these two decay modes are set by MEG
|
experimental limits on these two decay modes are set respectively by the MEG
|
||||||
experiment~\cite{Adam.etal.2013} and SINDRUM-II
|
experiment~\cite{Adam.etal.2013} and the SINDRUM-II
|
||||||
experiment~\cite{Bertl.etal.2006}:
|
experiment~\cite{Bertl.etal.2006}:
|
||||||
\begin{equation}
|
\begin{equation}
|
||||||
\mathcal{B}(\mu^+ \rightarrow e^+ \gamma) < 5.7 \times 10^{-13}
|
\mathcal{B}(\mu^+ \rightarrow e^+ \gamma) < 5.7 \times 10^{-13}\,,
|
||||||
\end{equation}
|
\end{equation}
|
||||||
, and:
|
and:
|
||||||
\begin{equation}
|
\begin{equation}
|
||||||
\mathcal{B} (\mu^- + Au \rightarrow e^- +Au) < 7\times 10^{-13}
|
\mathcal{B} (\mu^- + Au \rightarrow e^- +Au) < 7\times 10^{-13}\,.
|
||||||
\end{equation}
|
\end{equation}
|
||||||
|
|
||||||
%\hl{TODO: mueg and muec relations, Lagrangian \ldots}
|
%\hl{TODO: mueg and muec relations, Lagrangian \ldots}
|
||||||
@@ -278,32 +330,32 @@ experiment~\cite{Bertl.etal.2006}:
|
|||||||
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
|
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
|
||||||
\section{Phenomenology of \mueconv}
|
\section{Phenomenology of \mueconv}
|
||||||
\label{sec:phenomenoly_of_muec}
|
\label{sec:phenomenoly_of_muec}
|
||||||
The conversion of a captured muon into an electron in the field of a nucleus
|
The conversion of a captured negative muon in a muonic atom into an electron
|
||||||
has been one of the most powerful probe to search for CLFV. This section
|
in the field of a nucleus has been one of the most powerful probe to search for
|
||||||
|
CLFV. This section
|
||||||
highlights phenomenology of the \muec.
|
highlights phenomenology of the \muec.
|
||||||
|
|
||||||
\subsection{What is \mueconv}
|
\subsection{What is \mueconv}
|
||||||
\label{sub:what_is_muec}
|
\label{sub:what_is_muec}
|
||||||
When a muon is stopped in a material, it is quickly captured by atoms
|
When a negatively charged muon is stopped in a material, it is quickly captured
|
||||||
into a high orbital momentum state, forming a muonic atom, then
|
by an atom into a high orbital momentum state, forming a muonic atom, then
|
||||||
it rapidly cascades to the lowest state 1S. There, it undergoes either:
|
it rapidly cascades to the lowest state 1S. There, it undergoes either:
|
||||||
\begin{itemize}
|
\begin{itemize}
|
||||||
\item normal Michel decay: \micheldecay; or
|
\item normal Michel decay: \micheldecay; or
|
||||||
\item weak capture by the nucleus: $\mu^- p \rightarrow \nu_\mu n$
|
\item weak capture by the nucleus: $\mu^- p \rightarrow \nu_\mu n$.
|
||||||
\end{itemize}
|
\end{itemize}
|
||||||
|
|
||||||
In the context of physics beyond the SM, the exotic process of \mueconv where
|
In the context of physics beyond the SM, the exotic process of \mueconv where
|
||||||
a muon decays to an electron without neutrinos is also
|
a muon decays to an electron without neutrinos is also
|
||||||
expected, but it has never been observed.
|
expected, but has never been observed:
|
||||||
\begin{equation}
|
\begin{equation}
|
||||||
\mu^{-} + N(A,Z) \rightarrow e^{-} + N(A,Z)
|
\mu^{-} + N(A,Z) \rightarrow e^{-} + N(A,Z)\,.
|
||||||
\end{equation}
|
\end{equation}
|
||||||
The emitted electron in this decay
|
The emitted electron in this decay mode, the \mueconv electron, is
|
||||||
mode , the \mueconv electron, is mono-energetic at an energy far above the
|
mono-energetic at an energy far above the endpoint
|
||||||
endpoint
|
|
||||||
of the Michel spectrum (52.8 MeV):
|
of the Michel spectrum (52.8 MeV):
|
||||||
\begin{equation}
|
\begin{equation}
|
||||||
E_{\mu e} = m_\mu - E_b - \frac{E^2_\mu}{2m_N}
|
E_{\mu e} = m_\mu - E_b - \frac{E^2_\mu}{2m_N}\,.
|
||||||
\end{equation}
|
\end{equation}
|
||||||
where $m_\mu$ is the muon mas; $E_b \simeq Z^2\alpha^2 m_\mu/2$ is the binding
|
where $m_\mu$ is the muon mas; $E_b \simeq Z^2\alpha^2 m_\mu/2$ is the binding
|
||||||
energy of the muonic atom; and the last term is the nuclear recoil energy
|
energy of the muonic atom; and the last term is the nuclear recoil energy
|
||||||
@@ -322,8 +374,8 @@ The quantity measured in searches for \mueconv is the ratio between the rate of
|
|||||||
\frac{\Gamma(\mu^-N \rightarrow e^-N)}{\Gamma(\textrm{capture})}
|
\frac{\Gamma(\mu^-N \rightarrow e^-N)}{\Gamma(\textrm{capture})}
|
||||||
\label{eq:muerate_def}
|
\label{eq:muerate_def}
|
||||||
\end{equation}
|
\end{equation}
|
||||||
The normalisation to captures has advantages when one does calculation since
|
%The normalisation to captures has advantages when one does calculation since
|
||||||
many details of the nuclear wavefunction cancel out in the ratio.
|
%many details of the nuclear wavefunction cancel out in the ratio.
|
||||||
%Detailed
|
%Detailed
|
||||||
%calculations have been performed by Kitano et al.~\cite{KitanoKoike.etal.2002a,
|
%calculations have been performed by Kitano et al.~\cite{KitanoKoike.etal.2002a,
|
||||||
%KitanoKoike.etal.2007}, and Cirigliano et al.~\cite{Cirig}
|
%KitanoKoike.etal.2007}, and Cirigliano et al.~\cite{Cirig}
|
||||||
@@ -340,7 +392,10 @@ The mean lifetime $\tau = 1/\Gamma$, then:
|
|||||||
\end{equation}
|
\end{equation}
|
||||||
The mean lifetimes of free muons and muons in a material are well-known,
|
The mean lifetimes of free muons and muons in a material are well-known,
|
||||||
therefore the number of captures can be inferred from the number of stops. For
|
therefore the number of captures can be inferred from the number of stops. For
|
||||||
aluminium, $\frac{\Gamma_{\textrm{capture}}}{\Gamma_{\textrm{stop}}} = 0.609$
|
aluminium,
|
||||||
|
\begin{equation}
|
||||||
|
\frac{\Gamma_{\textrm{capture}}}{\Gamma_{\textrm{stop}}} = 0.609
|
||||||
|
\end{equation}
|
||||||
and the mean lifetime of stopped muons is 864
|
and the mean lifetime of stopped muons is 864
|
||||||
ns~\cite{SuzukiMeasday.etal.1987}.
|
ns~\cite{SuzukiMeasday.etal.1987}.
|
||||||
|
|
||||||
|
|||||||
@@ -5,8 +5,8 @@
|
|||||||
This chapter describes the new experimental search for \mueconv, namely COMET -
|
This chapter describes the new experimental search for \mueconv, namely COMET -
|
||||||
(\textbf{CO}herent \textbf{M}uon to \textbf{E}lectron \textbf{T}ransition). The
|
(\textbf{CO}herent \textbf{M}uon to \textbf{E}lectron \textbf{T}ransition). The
|
||||||
experiment will be carried out at the Japan Proton Accelerator Research Complex
|
experiment will be carried out at the Japan Proton Accelerator Research Complex
|
||||||
(J-PARC), aims at a sensitivity of \sn{6}{-17} i.e. 10,000 times better than the
|
(J-PARC), aims at a single event sensitivity of \num{6E-17}, i.e. 10,000 times
|
||||||
current best limit.
|
better than the current best limit.
|
||||||
|
|
||||||
%At the Japan Proton Accelerator Research Complex (J-PARC), an experiment to
|
%At the Japan Proton Accelerator Research Complex (J-PARC), an experiment to
|
||||||
%search for \muec~conversion, which is called
|
%search for \muec~conversion, which is called
|
||||||
@@ -48,8 +48,9 @@ current best limit.
|
|||||||
|
|
||||||
The searches for \mueconv has been ongoing for more than 50 years, started in
|
The searches for \mueconv has been ongoing for more than 50 years, started in
|
||||||
1952 with cosmic rays~\cite{LagarriguePeyrou.1952} and then moved to
|
1952 with cosmic rays~\cite{LagarriguePeyrou.1952} and then moved to
|
||||||
accelerators. The list in the Table~\ref{tab:mueconv_history} is reproduced
|
accelerators. The list of upper limits for \mueconv in
|
||||||
from a recent review of Bernstein and Cooper~\cite{BernsteinCooper.2013}.
|
\cref{tab:mueconv_history} is reproduced from a recent review of Bernstein
|
||||||
|
and Cooper~\cite{BernsteinCooper.2013}.
|
||||||
\begin{table}[htb]
|
\begin{table}[htb]
|
||||||
\begin{center}
|
\begin{center}
|
||||||
\begin{tabular}{l l l c}
|
\begin{tabular}{l l l c}
|
||||||
@@ -62,57 +63,63 @@ from a recent review of Bernstein and Cooper~\cite{BernsteinCooper.2013}.
|
|||||||
1961 & \sn{4.0}{-6} & Cu & \cite{SardCrowe.etal.1961}\\
|
1961 & \sn{4.0}{-6} & Cu & \cite{SardCrowe.etal.1961}\\
|
||||||
1961 & \sn{5.9}{-6} & Cu & \cite{ConversiLella.etal.1961}\\
|
1961 & \sn{5.9}{-6} & Cu & \cite{ConversiLella.etal.1961}\\
|
||||||
1962 & \sn{2.2}{-7} & Cu & \cite{ConfortoConversi.etal.1962}\\
|
1962 & \sn{2.2}{-7} & Cu & \cite{ConfortoConversi.etal.1962}\\
|
||||||
1964 & \sn{2.2}{-7} & Cu & \cite{ConversiLella.etal.1961}\\
|
1964 & \sn{2.2}{-7} & Cu & \cite{BartleyDavies.etal.1964}\\
|
||||||
1972 & \sn{2.6}{-8} & Cu & \cite{ConversiLella.etal.1961}\\
|
1972 & \sn{2.6}{-8} & Cu & \cite{BrymanBlecher.etal.1972}\\
|
||||||
1977 & \sn{4.0}{-10} & S & \cite{ConversiLella.etal.1961}\\
|
1977 & \sn{4.0}{-10} & S & \cite{BadertscherBorer.etal.1977}\\
|
||||||
1982 & \sn{7.0}{-11} & S & \cite{ConversiLella.etal.1961}\\
|
1982 & \sn{7.0}{-11} & S & \cite{BadertscherBorer.etal.1982a}\\
|
||||||
1988 & \sn{4.6}{-12} & Ti & \cite{ConversiLella.etal.1961}\\
|
1988 & \sn{4.6}{-12} & Ti & \cite{AhmadAzuelos.etal.1988a}\\
|
||||||
1993 & \sn{4.3}{-12} & Ti & \cite{ConversiLella.etal.1961}\\
|
1993 & \sn{4.3}{-12} & Ti & \cite{DohmenGroth.etal.1993}\\
|
||||||
1995 & \sn{6.5}{-13} & Ti & \cite{ConversiLella.etal.1961}\\
|
1996 & \sn{4.6}{-11} & Pb & \cite{HoneckerDohmen.etal.1996}\\
|
||||||
1996 & \sn{4.6}{-11} & Pb & \cite{ConversiLella.etal.1961}\\
|
2006 & \sn{7.0}{-13} & Au & \cite{Bertl.etal.2006}\\
|
||||||
2006 & \sn{7.0}{-13} & Au & \cite{ConversiLella.etal.1961}\\
|
|
||||||
\bottomrule
|
\bottomrule
|
||||||
|
%%TODO fix ref
|
||||||
\end{tabular}
|
\end{tabular}
|
||||||
\end{center}
|
\end{center}
|
||||||
\caption{History of \mueconv experiments, reproduced
|
\caption{History of \mueconv experiments with more and more stringent upper
|
||||||
from~\cite{BernsteinCooper.2013}}
|
limit.}
|
||||||
\label{tab:mueconv_history}
|
\label{tab:mueconv_history}
|
||||||
\end{table}
|
\end{table}
|
||||||
|
|
||||||
The most recent experiments were the SINDRUM and SINDRUM-II at the Paul
|
The latest experiments were the SINDRUM and SINDRUM-II at the Paul
|
||||||
Scherrer Institute (PSI), Switzerland. The SINDRUM-II measured the branching
|
Scherrer Institute (PSI), Switzerland. The SINDRUM-II
|
||||||
|
(\cref{fig:sindrumII_setup}) measured the branching
|
||||||
ratio of \mueconv on a series of heavy targets: Ti, Pb and Au. The proton beam
|
ratio of \mueconv on a series of heavy targets: Ti, Pb and Au. The proton beam
|
||||||
at PSI is a continuous wave beam, with a time structure of 0.3 ns bursts every
|
at PSI is a continuous beam, with a time structure of 0.3 ns bursts every
|
||||||
19.75 \si{\nano\second}. An 8-\si{\milli\meter}-thick CH$_2$ degrader was used to reduce
|
19.75 \si{\nano\second}. An 8-\si{\milli\meter}-thick CH$_2$ degrader was used
|
||||||
the radiative pion capture and other prompt backgrounds. Cosmic backgrounds are
|
to reduce the radiative pion capture and other prompt backgrounds. Cosmic
|
||||||
|
backgrounds are
|
||||||
rejected using a combination of
|
rejected using a combination of
|
||||||
passive shielding, veto counters and reconstruction cuts. The momenta of muons
|
passive shielding, veto counters and reconstruction cuts. The momenta of beam
|
||||||
were 52 \si{\mega\electronvolt\per\cc} and 53 \si{\mega\electronvolt\per\cc}, and the
|
muons used in the experiment were \SI{52}{\MeV\per\cc} and
|
||||||
momentum spread was 2\%.
|
\SI{53}{\MeV\per\cc}, and the momentum spread was 2\%.
|
||||||
\begin{figure}[htbp] \centering
|
\begin{figure}[htbp] \centering
|
||||||
\includegraphics[width=0.85\textwidth]{figs/sindrumII_setup}
|
\includegraphics[width=0.85\textwidth]{figs/sindrumII_setup}
|
||||||
\caption{SINDRUM-II set up}
|
\caption{SINDRUM-II experimental set up, reprinted from
|
||||||
|
reference~\cite{Bertl.etal.2006} with permission from Springer.}
|
||||||
\label{fig:sindrumII_setup}
|
\label{fig:sindrumII_setup}
|
||||||
\end{figure}
|
\end{figure}
|
||||||
|
|
||||||
Electrons emitted from the target were tracked in a 0.33 T solenoid field.
|
Electrons emitted from the target were tracked in a 0.33 T solenoidal magnetic
|
||||||
Detector system consisted of a superconducting solenoid, two plastic
|
field. Detector system consisted of a superconducting solenoid, two plastic
|
||||||
scintillation hodoscopes, a plexiglass Cerenkov hodoscope, and two drift
|
scintillation hodoscopes, a plexiglass Cerenkov hodoscope, and two drift
|
||||||
chambers. In the latest measurement, the SINDRUM-II collaboration have not
|
chambers. In the latest measurement, the SINDRUM-II collaboration have not
|
||||||
found any conversion electron from captured muons in a gold target, hence set
|
found any conversion electron from captured muons in a gold target, hence set
|
||||||
the upper limit for
|
the upper limit for
|
||||||
the branching ratio of \mueconv in gold with 90 \% C.L. at \sn{7.0}{-13}.
|
the branching ratio of \mueconv in gold with 90 \% C.L. at \num{7.0E-13}.
|
||||||
|
|
||||||
The reconstructed momenta of electrons around the signal region from SINDRUM-II
|
The reconstructed momenta of electrons around the signal region from SINDRUM-II
|
||||||
is shown in the Figure~\ref{fig:sindrumII_result}. It can be seen that the muon
|
is shown in \cref{fig:sindrumII_result}. It can be seen that the muon
|
||||||
decay in orbit background falls steeply near the endpoint as expected, but, the
|
decay in orbit background falls steeply near the endpoint as expected, but, the
|
||||||
prompt background induced by pions still remains even after the cut in timing
|
prompt background induced by pions still remains even after the cut in timing
|
||||||
and track angle. This indicates the problem of pion contamination is very
|
and track angle. This indicates the problem of pion contamination is very
|
||||||
important in probing lower sensitivity.
|
important in probing better sensitivity.
|
||||||
\begin{figure}[htbp]
|
\begin{figure}[htbp]
|
||||||
\centering
|
\centering
|
||||||
\includegraphics[width=0.55\textwidth]{figs/sindrumII_Au_result}
|
\includegraphics[width=0.55\textwidth]{figs/sindrumII_Au_result}
|
||||||
\caption{SINDRUM-II result}
|
\caption{SINDRUM-II results showing background events reaching into the
|
||||||
|
signal region. Reprinted from reference~\cite{Bertl.etal.2006} with
|
||||||
|
permission from Springer.}
|
||||||
|
%TODO: explain top and bottom figure
|
||||||
\label{fig:sindrumII_result}
|
\label{fig:sindrumII_result}
|
||||||
\end{figure}
|
\end{figure}
|
||||||
% subsection experimental_history (end)
|
% subsection experimental_history (end)
|
||||||
@@ -124,28 +131,30 @@ A new generation of \mueconv experiments have been proposed with scenarios to
|
|||||||
overcome pion induced background in the SINDRUM-II. Lobashev and collaborators
|
overcome pion induced background in the SINDRUM-II. Lobashev and collaborators
|
||||||
first suggested the basic idea for new \mueconv at the Moscow Muon Factory;
|
first suggested the basic idea for new \mueconv at the Moscow Muon Factory;
|
||||||
this idea was used to develop the MECO experiment at Brookhaven National
|
this idea was used to develop the MECO experiment at Brookhaven National
|
||||||
Laboratory. The MECO experiment was cancelled due to budget constraints. The two
|
Laboratory. The MECO experiment was cancelled due to budget constraints. Two
|
||||||
modern experiments, COMET at J-PARC and Mu2e at Fermilab use the initial idea
|
recent experiments, COMET at J-PARC and Mu2e at Fermilab, use the initial idea
|
||||||
with more upgrades and modifications.
|
with more upgrades and modifications.
|
||||||
|
|
||||||
The basic ideas of the modern experiments are:
|
The basic ideas of the two experiments are:
|
||||||
\begin{enumerate}
|
\begin{enumerate}
|
||||||
\item Highly intense muon source: the total number of muons needed is of the
|
\item Highly intense muon source: the total number of muons needed is of the
|
||||||
order of $10^{18}$ in order to achieve a sensitivity of $10^{-16}$. This
|
order of $10^{18}$ in order to achieve a sensitivity of $10^{-16}$. This
|
||||||
can be done by producing more pions using a high power proton beam, and
|
can be done by producing more pions using a high power proton beam, and
|
||||||
having a high efficiency pion collection system;
|
having a high efficiency pion collection system;
|
||||||
\item Pulsed proton beam with an appropriate timing: the proton pulse should
|
\item Pulsed proton beam: the proton pulse should
|
||||||
be short compares to the lifetime of muons in the stopping target material,
|
be short compares to the lifetime of muons in the stopping target material,
|
||||||
and the period between pulses should be long enough for prompt backgrounds
|
and the period between pulses should be long enough for prompt backgrounds
|
||||||
from pion to decay before beginning the measurement. It is also crucial
|
from pion to decay before beginning the measurement. It is also crucial
|
||||||
that there is no proton leaks into the measuring interval;
|
that there is no proton leaks into the measuring interval;
|
||||||
\item Curved solenoids for charge and momentum selection: at first, the curved
|
\item Curved solenoids for charge and momentum selection: at first, the curved
|
||||||
solenoids remove the line of sight backgrounds. A charged particle travels
|
solenoids remove the line of sight backgrounds. A charged particle travels
|
||||||
through a curved solenoidal field will have the centre of the helical
|
through a curved solenoidal magnetic field has the centre of the helical
|
||||||
motion drifted up or down depends on the sign of the charge, and the
|
motion drifted up or down with respect to the bending plane depends on the
|
||||||
magnitude of the drift is proportional to its momentum. By using this
|
sign of the charge, and the magnitude of the drift is proportional to its
|
||||||
effect and placing suitable collimators, charge and momentum selection can
|
momentum. By using this effect and placing suitable collimators, charge and
|
||||||
be made.
|
momentum selection can be made. Details of the magnet system are described
|
||||||
|
in \cref{sub:pion_production_can_capture_solenoid} and
|
||||||
|
\cref{sub:pion_and_muon_transportation}.
|
||||||
\end{enumerate}
|
\end{enumerate}
|
||||||
% subsection new_generation_of_mueconv_experiments (end)
|
% subsection new_generation_of_mueconv_experiments (end)
|
||||||
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
|
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
|
||||||
@@ -156,13 +165,14 @@ The basic ideas of the modern experiments are:
|
|||||||
\section{Concepts of the COMET experiment}
|
\section{Concepts of the COMET experiment}
|
||||||
\label{sec:concepts_of_the_comet_experiment}
|
\label{sec:concepts_of_the_comet_experiment}
|
||||||
This section elaborates the design choices of the COMET to realise the basic
|
This section elaborates the design choices of the COMET to realise the basic
|
||||||
ideas mentioned above. Figures and numbers, other than noted, are taken from
|
ideas mentioned previously. Figures and numbers, other than noted, are taken
|
||||||
the COMET's documentations:
|
from the COMET's documentations:
|
||||||
\begin{itemize}
|
\begin{itemize}
|
||||||
%TODO citations
|
%TODO citations
|
||||||
\item Conceptual design report for the COMET experiment~\cite{COMET.2009}
|
\item Conceptual design report for the COMET experiment~\cite{COMET.2009},
|
||||||
\item Proposal Phase-I 2012
|
\item Experimental Proposal for Phase-I of the COMET Experiment at
|
||||||
\item TDR 2014
|
J-PARC~\cite{COMET.2012},
|
||||||
|
\item and COMET Phase-I Technical Design Report~\cite{COMET.2014}.
|
||||||
\end{itemize}
|
\end{itemize}
|
||||||
|
|
||||||
|
|
||||||
@@ -172,30 +182,30 @@ A high power pulsed proton beam is of utmost importance to achieve the desired
|
|||||||
sensitivity of the COMET experiment. A slow-extracted proton beam from
|
sensitivity of the COMET experiment. A slow-extracted proton beam from
|
||||||
the J-PARC main ring (MR), which is designed to deliver \sn{3.6}{15} protons per
|
the J-PARC main ring (MR), which is designed to deliver \sn{3.6}{15} protons per
|
||||||
cycle at a frequency of 0.45 Hz, will be used for the COMET experiment. The
|
cycle at a frequency of 0.45 Hz, will be used for the COMET experiment. The
|
||||||
proton beam power of the current design is 8 GeV$\times$7 $\mu$A, or
|
proton beam power of the current design is $\SI{8}{\GeV}\times \SI{7}{\uA}$, or
|
||||||
\sn{4.4}{13} protons/s. The beam energy 8 \si{\giga\electronvolt} helps to minimise
|
\num{4.4E13} protons/s at \SI{8}{\GeV}. The beam energy was chosen to minimise
|
||||||
the production of antiprotons.
|
the production of antiprotons which may introduce background events.
|
||||||
|
|
||||||
The proton pulse width is chosen to be 100 ns, and the pulse period to be
|
The proton pulse width is chosen to be 100 ns, and the pulse period to be
|
||||||
$1 \sim 2 \textrm{ }\mu\textrm{s}$. This time structure is sufficient for the
|
from \SIrange{1}{2}{\us}. This time structure is sufficient for the
|
||||||
search for \mueconv in an aluminium target where the lifetime of muons is 864
|
search for \mueconv in an aluminium target where the mean lifetime of negative
|
||||||
ns. A plan of accelerator operation to realise the scheme is shown in
|
muons in muonic atoms is \SI{864}{\ns}. One possible plan of accelerator
|
||||||
the Figure~\ref{fig:comet_mr_4filled}, where 4 out of 9 MR buckets are filled.
|
operation to realise the beam pulsing is shown in \cref{fig:comet_mr_4filled},
|
||||||
|
where 4 out of 9 MR buckets are filled.
|
||||||
|
|
||||||
As mentioned, it is very important that there is no stray proton arrives in the
|
As mentioned, it is very important that there is no stray proton arrives in the
|
||||||
measuring period between two proton bunches. An extinction factor is defined as
|
measuring period between two proton bunches. An extinction factor is defined as
|
||||||
the ratio between number of protons in between two pulses and the number of
|
the ratio between number of protons in between two pulses and the number of
|
||||||
protons in the main pulse. In order to achieve the goal sensitivity of the
|
protons in the main pulse. In order to achieve the goal sensitivity of the
|
||||||
COMET, an extinction factor of \sn{}{-9} is required.
|
COMET, an extinction factor less than \num{E-9} is required.
|
||||||
|
|
||||||
Requirements for the proton beam are summarised in the
|
Requirements for the proton beam are summarised in \cref{tab:comet_proton_beam}.
|
||||||
Table~\ref{tab:comet_proton_beam}.
|
|
||||||
|
|
||||||
\begin{figure}[htb]
|
\begin{figure}[htb]
|
||||||
\centering
|
\centering
|
||||||
\includegraphics[width=0.8\textwidth]{figs/comet_mr_4filled}
|
\includegraphics[width=0.8\textwidth]{figs/comet_mr_4filled}
|
||||||
\caption{The COMET proton bunch structure in the RCS (rapid cycle
|
\caption{The COMET proton bunch structure in the RCS (Rapid Cycling
|
||||||
synchrotron) and MR where 4 buckets
|
Synchrotron) and MR where 4 buckets
|
||||||
are filled producing 100 \si{\nano\second} bunches separated by
|
are filled producing 100 \si{\nano\second} bunches separated by
|
||||||
1.2~\si{\micro\second}.}
|
1.2~\si{\micro\second}.}
|
||||||
\label{fig:comet_mr_4filled}
|
\label{fig:comet_mr_4filled}
|
||||||
@@ -234,7 +244,7 @@ pions, are preferred. It is known from other measurements that backward
|
|||||||
scattered pions (with respect to proton beam direction) of high energy are
|
scattered pions (with respect to proton beam direction) of high energy are
|
||||||
suppressed, and the yield of low energy pions in the backward direction is not
|
suppressed, and the yield of low energy pions in the backward direction is not
|
||||||
too low compares to that of the forward direction (see
|
too low compares to that of the forward direction (see
|
||||||
Figure~\ref{fig:pion_yield}). For these reasons, the COMET
|
\cref{fig:pion_yield}). For these reasons, the COMET
|
||||||
decided to collect backward pions.
|
decided to collect backward pions.
|
||||||
\begin{figure}[htb]
|
\begin{figure}[htb]
|
||||||
\centering
|
\centering
|
||||||
@@ -243,10 +253,9 @@ decided to collect backward pions.
|
|||||||
target.}
|
target.}
|
||||||
\label{fig:pion_yield}
|
\label{fig:pion_yield}
|
||||||
\end{figure}
|
\end{figure}
|
||||||
|
|
||||||
The pion capture system is composed of several superconducting solenoids:
|
The pion capture system is composed of several superconducting solenoids:
|
||||||
capture solenoids and matching solenoids. The magnetic field distribution along
|
capture solenoids and matching solenoids. The magnetic field distribution along
|
||||||
the beam axis of the COMET is shown in the Figure~\ref{fig:comet_Bfield}. The
|
the beam axis of the COMET is shown in \cref{fig:comet_Bfield}. The
|
||||||
peak field of 5 T is created by the capture solenoid, and the matching
|
peak field of 5 T is created by the capture solenoid, and the matching
|
||||||
solenoids provide a smooth transition from that peak field to the 3 T field in
|
solenoids provide a smooth transition from that peak field to the 3 T field in
|
||||||
the pions/muons transportation region. The superconducting solenoids are
|
the pions/muons transportation region. The superconducting solenoids are
|
||||||
@@ -258,6 +267,7 @@ will be installed inside the cryostat to reduce radiation heat load.
|
|||||||
\caption{Magnetic field distribution along the COMET beam line.}
|
\caption{Magnetic field distribution along the COMET beam line.}
|
||||||
\label{fig:comet_Bfield}
|
\label{fig:comet_Bfield}
|
||||||
\end{figure}
|
\end{figure}
|
||||||
|
%TODO full comet field
|
||||||
|
|
||||||
% subsection pion_production_can_capture_solenoid (end)
|
% subsection pion_production_can_capture_solenoid (end)
|
||||||
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
|
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
|
||||||
@@ -266,7 +276,7 @@ will be installed inside the cryostat to reduce radiation heat load.
|
|||||||
Muons and pions are transported to the muon stopping target through a muon
|
Muons and pions are transported to the muon stopping target through a muon
|
||||||
beam line, which includes several curved and straight superconducting solenoid
|
beam line, which includes several curved and straight superconducting solenoid
|
||||||
magnets. A schematic layout of the muon beam line, include the capture and
|
magnets. A schematic layout of the muon beam line, include the capture and
|
||||||
detector sections, is shown in Figure~\ref{fig:comet_beamline_layout}.
|
detector sections, is shown in \cref{fig:comet_beamline_layout}.
|
||||||
\begin{figure}[htb]
|
\begin{figure}[htb]
|
||||||
\centering
|
\centering
|
||||||
\includegraphics[width=0.95\textwidth]{figs/comet_beamline_layout}
|
\includegraphics[width=0.95\textwidth]{figs/comet_beamline_layout}
|
||||||
@@ -292,7 +302,7 @@ of the drift is given by:
|
|||||||
&= \frac{1}{qB} \frac{s}{R} \frac{p}{2}
|
&= \frac{1}{qB} \frac{s}{R} \frac{p}{2}
|
||||||
\left( \textrm{cos}\theta + \frac{1}{\textrm{cos}\theta} \right)\\
|
\left( \textrm{cos}\theta + \frac{1}{\textrm{cos}\theta} \right)\\
|
||||||
&= \frac{1}{qB} \theta_{bend} \frac{p}{2}
|
&= \frac{1}{qB} \theta_{bend} \frac{p}{2}
|
||||||
\left( \textrm{cos}\theta + \frac{1}{\textrm{cos}\theta} \right)
|
\left( \textrm{cos}\theta + \frac{1}{\textrm{cos}\theta} \right)\,,
|
||||||
\end{align}
|
\end{align}
|
||||||
where $q$ is the electric charge of the particle; $B$ is the magnetic field at
|
where $q$ is the electric charge of the particle; $B$ is the magnetic field at
|
||||||
the axis; $s$ and $R$ are the path length and the radius of the curvature; $p$,
|
the axis; $s$ and $R$ are the path length and the radius of the curvature; $p$,
|
||||||
@@ -312,7 +322,7 @@ produced by additional coils winded around the solenoid coils. The magnitude of
|
|||||||
the compensating field is:
|
the compensating field is:
|
||||||
\begin{equation}
|
\begin{equation}
|
||||||
B_{\textrm{comp}} = \frac{1}{qR} \frac{p_0}{2}
|
B_{\textrm{comp}} = \frac{1}{qR} \frac{p_0}{2}
|
||||||
\left( \textrm{cos}\theta_0 + \frac{1}{\textrm{cos}\theta_0} \right)
|
\left( \textrm{cos}\theta_0 + \frac{1}{\textrm{cos}\theta_0} \right)\,,
|
||||||
\end{equation}
|
\end{equation}
|
||||||
where the trajectories of charged particles with momentum $p_0$ and pitch angle
|
where the trajectories of charged particles with momentum $p_0$ and pitch angle
|
||||||
$\theta_0$ are corrected to be on-axis. An average dipole field of 0.03 T is
|
$\theta_0$ are corrected to be on-axis. An average dipole field of 0.03 T is
|
||||||
@@ -321,23 +331,44 @@ needed to select 40 MeV/$c$ muons as required by the COMET design.
|
|||||||
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
|
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
|
||||||
\subsection{Muon stopping target}
|
\subsection{Muon stopping target}
|
||||||
\label{sub:muon_stopping_target}
|
\label{sub:muon_stopping_target}
|
||||||
Muon stopping target is place at 180\si{\degree}~bending after the pion production
|
Muon stopping target is place at 180\si{\degree}~bending after the pion
|
||||||
target (Figure~\ref{fig:comet_beamline_layout}) in its own solenoid. The target
|
production target (\cref{fig:comet_beamline_layout}) in its own solenoid. The
|
||||||
|
target
|
||||||
is designed to maximise the muon stopping efficiency and minimise the energy
|
is designed to maximise the muon stopping efficiency and minimise the energy
|
||||||
loss of signal electrons.
|
loss of signal electrons.
|
||||||
|
|
||||||
%\hl{TODO: Target choice: separation, product, lifetime, energy loss\ldots}
|
%\hl{TODO: Target choice: separation, product, lifetime, energy loss\ldots}
|
||||||
It is calculated that the branching ratio of \mueconv increases with atomic
|
It is calculated that the branching ratio of \mueconv increases with atomic
|
||||||
number $Z$, and plateaus above $Z \simeq 30$, then decreases as $Z>60$. The
|
number $Z$, and plateaus above $Z \simeq 30$, then decreases as $Z>60$ (see
|
||||||
lifetime of muons inside a material decreases quickly as $Z$ increases.
|
\cref{fig:comet_mueconv_RateVsZ}). Although the sensitivity is better for
|
||||||
Tracking wise, lower $Z$ material provides better reconstructed momentum
|
higher $Z$ material, the acceptance of the measurement time window decreases
|
||||||
resolution. Therefore, light material is preferable as muon stopping target.
|
quickly because the average lifetime of negative muons inside a material
|
||||||
|
decreases as $Z^{-4}$.
|
||||||
|
%Tracking wise, lower $Z$ material provides better
|
||||||
|
%reconstructed momentum
|
||||||
|
%resolution.
|
||||||
|
Therefore, light material is preferable as muon stopping target.
|
||||||
|
\begin{figure}[hbp]
|
||||||
|
\centering
|
||||||
|
\includegraphics[width=0.60\textwidth]{figs/comet_mueconv_RateVsZ}
|
||||||
|
\caption{Target dependence of the \mueconv rate in different models
|
||||||
|
calculated by Cirigliano and colleagues~\cite{CiriglianoKitano.etal.2009}.
|
||||||
|
The conversion rates are normalised to the rate in aluminium. Four models
|
||||||
|
were considered and noted with letters: D for dipole-interaction-dominated
|
||||||
|
model, V for vector and S for scalar interactions. The three vertical lines
|
||||||
|
from left to right correspond to $Z=13$(Al), $Z=22$(Ti), and $Z=82$(Pb)
|
||||||
|
respectively. Reprinted figure from
|
||||||
|
reference~\cite{CiriglianoKitano.etal.2009}. Copyright 2009 by the
|
||||||
|
American Physical Society.}
|
||||||
|
\label{fig:comet_mueconv_RateVsZ}
|
||||||
|
\end{figure}
|
||||||
|
|
||||||
The first choice for the muon stopping target material in the COMET is
|
The first choice for the muon stopping target material in the COMET is
|
||||||
aluminium. A titanium target is also considered. Configuration of the target is
|
aluminium. A titanium target is also considered in the future. Configuration of
|
||||||
shown in the Table~\ref{tab:comet_al_target}. Monte Carlo studies with this
|
the target is shown in \cref{tab:comet_al_target}. Monte Carlo studies with
|
||||||
|
this
|
||||||
design showed that net stopping efficiency is 0.29, and average energy loss
|
design showed that net stopping efficiency is 0.29, and average energy loss
|
||||||
of signal electrons is about 400 \si{\kilo\electronvolt}.
|
of signal electrons is about \SI{400}{\keV}.
|
||||||
\begin{table}[htb]
|
\begin{table}[htb]
|
||||||
\begin{center}
|
\begin{center}
|
||||||
\begin{tabular}{l l}
|
\begin{tabular}{l l}
|
||||||
@@ -358,7 +389,7 @@ of signal electrons is about 400 \si{\kilo\electronvolt}.
|
|||||||
\end{table}
|
\end{table}
|
||||||
|
|
||||||
A graded magnetic field (reduces from 3 T to 1 T) is produced at the
|
A graded magnetic field (reduces from 3 T to 1 T) is produced at the
|
||||||
location of the stopping target (see Figure~\ref{fig:comet_target_Bfield}) to
|
location of the stopping target (see \cref{fig:comet_target_Bfield}) to
|
||||||
maximise the acceptance for \mueconv signals, since electrons emitted in the
|
maximise the acceptance for \mueconv signals, since electrons emitted in the
|
||||||
backward
|
backward
|
||||||
direction would be reflected due to magnetic mirroring. The graded field also
|
direction would be reflected due to magnetic mirroring. The graded field also
|
||||||
@@ -375,36 +406,36 @@ transport section.
|
|||||||
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
|
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
|
||||||
\subsection{Electron transportation beam line}
|
\subsection{Electron transportation beam line}
|
||||||
\label{sub:electron_transportation_beam_line}
|
\label{sub:electron_transportation_beam_line}
|
||||||
The 180\si{\degree}~bending electron transport solenoids help remove line-of-sight
|
The \ang{180} bending electron transport solenoids help remove line-of-sight
|
||||||
between the target and the detector system. It works similarly to the muon
|
between the target and the detector system. It works similarly to the muon
|
||||||
transportation section, but is tuned differently to accept electrons of about
|
transportation section, but is tuned differently to accept electrons of about
|
||||||
105~\si{\mega\electronvolt\per\cc}. A compensation field of 0.17 T along the
|
\SI{105}{\MeV\per\cc}. A compensation field of \SI{0.17}{\tesla} along the
|
||||||
vertical direction will be applied. Electrons with momentum less than 80
|
vertical direction will be applied. Electrons with momentum less than
|
||||||
\si{\mega\electronvolt\per\cc} are blocked at the exit of this section by
|
\SI{80}{\MeV\per\cc} are blocked at the exit of this section by
|
||||||
a collimator to reduce DIO electrons rate. The net acceptance of signals of
|
a collimator to reduce DIO electrons rate. The net acceptance of signals of
|
||||||
\mueconv is about 0.32, and the detector hit rate will be in the order of
|
\mueconv is about 0.32, and the detector hit rate will be in the order of
|
||||||
1~\si{\kilo\hertz}~for \sn{}{11} stopped muons\si{\per\second}.
|
\SI{1}{\kHz} for a muon stopping rate of \SI{E11}{\Hz}.
|
||||||
% subsection electron_transportation_beam_line (end)
|
% subsection electron_transportation_beam_line (end)
|
||||||
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
|
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
|
||||||
\subsection{Electron detectors}
|
\subsection{Electron detectors}
|
||||||
\label{sub:electron_detectors}
|
\label{sub:electron_detectors}
|
||||||
The \mueconv signal electrons is measured by an electron detector system, which
|
The \mueconv signal electrons is measured by an electron detector system, which
|
||||||
consists of straw-tube trackers and an electromagnetic calorimeter - shown in
|
consists of straw-tube trackers and an electromagnetic calorimeter - shown in
|
||||||
Figure~\ref{fig:comet_detector_system}. The
|
\cref{fig:comet_detector_system}. The
|
||||||
requirements for the detector system is to distinguish electrons from other
|
requirements for the detector system is to distinguish electrons from other
|
||||||
particles, and measure their momenta, energy and timings. The whole detector
|
particles, and measure their momenta, energy and timings. The whole detector
|
||||||
system is in a uniform solenoidal magnetic field under vacuum. Passive and
|
system is in a uniform solenoidal magnetic field under vacuum. Passive and
|
||||||
active shielding against cosmic rays is considered.
|
active shielding against cosmic rays is considered.
|
||||||
|
|
||||||
The tracking detector has to provide a momentum resolution less than
|
The tracking detector has to provide a momentum resolution less than
|
||||||
|
%%TODO 350 or 150?
|
||||||
350~\si{\kilo\electronvolt\per\cc} in order to achieve a sensitivity of
|
350~\si{\kilo\electronvolt\per\cc} in order to achieve a sensitivity of
|
||||||
\sn{3}{-17}. There are five stations of straw-tube gas chambers, each provides
|
\sn{3}{-17}. There are five stations of straw-tube gas chambers, each provides
|
||||||
two
|
two dimensional information. Each straw tube is 5~\si{\milli\meter} in diameter
|
||||||
dimensional information. Each straw tube is 5~\si{\milli\meter} in diameter and has
|
and has a 25-\si{\micro\meter}-thick wall. According to a GEANT4 Monte Carlo
|
||||||
a 25~\si{\micro\meter}-thick wall. According to a GEANT4 Monte Carlo simulation,
|
simulation, a position resolution of 250~\si{\micro\meter} can be obtained,
|
||||||
a position resolution of 250~\si{\micro\meter} can be obtained, which is enough for
|
which is enough for 350~\si{\kilo\electronvolt\per\cc} momentum resolution. The
|
||||||
350~\si{\kilo\electronvolt\per\cc} momentum resolution. The DIO background of 0.15
|
DIO background of 0.15 events is expected.
|
||||||
events is estimated.
|
|
||||||
|
|
||||||
The electromagnetic calorimeter serves three purposes: a) to measure electrons
|
The electromagnetic calorimeter serves three purposes: a) to measure electrons
|
||||||
energy with high energy resolution; b) to provide timing information and
|
energy with high energy resolution; b) to provide timing information and
|
||||||
@@ -427,7 +458,7 @@ The requirements for \mueconv signals are:
|
|||||||
muons decay in flight;
|
muons decay in flight;
|
||||||
\item timing wise, conversion electrons should arrive in the time window of
|
\item timing wise, conversion electrons should arrive in the time window of
|
||||||
detection which is about 700~\si{\nano\second}~after each proton pulses
|
detection which is about 700~\si{\nano\second}~after each proton pulses
|
||||||
(Figure~\ref{fig:comet_meas_timing}). The acceptance in this detection
|
(\cref{fig:comet_meas_timing}). The acceptance in this detection
|
||||||
window is about 0.39 for aluminium.
|
window is about 0.39 for aluminium.
|
||||||
\end{itemize}
|
\end{itemize}
|
||||||
|
|
||||||
@@ -472,7 +503,7 @@ Potential backgrounds for the COMET are:
|
|||||||
\item Accidental background from cosmic rays
|
\item Accidental background from cosmic rays
|
||||||
\end{enumerate}
|
\end{enumerate}
|
||||||
The expected background rates for the COMET at an SES of
|
The expected background rates for the COMET at an SES of
|
||||||
\sn{3}{-17} is summarised in Table~\ref{tab:comet_background_estimation}.
|
\sn{3}{-17} is summarised in \cref{tab:comet_background_estimation}.
|
||||||
\begin{table}[htb]
|
\begin{table}[htb]
|
||||||
\begin{center}
|
\begin{center}
|
||||||
%\begin{tabular}{l l}
|
%\begin{tabular}{l l}
|
||||||
@@ -516,11 +547,12 @@ are believed to greatly reduce potential backgrounds, by several orders of
|
|||||||
magnitude, for the \mueconv search. That also means that backgrounds are being
|
magnitude, for the \mueconv search. That also means that backgrounds are being
|
||||||
extrapolated over four orders of magnitude from existing data. In order to
|
extrapolated over four orders of magnitude from existing data. In order to
|
||||||
obtain data-driven estimates of backgrounds, and inform the detailed design for
|
obtain data-driven estimates of backgrounds, and inform the detailed design for
|
||||||
the ultimate COMET experiment, and initial phase is desirable. Also, the 5-year
|
the ultimate COMET experiment, a staged approach is desirable. Also, the
|
||||||
mid-term plan from 2013 of J-PARC includes the construction of the COMET beam
|
KEK/J-PARC 5-year mid-term plan from 2013 includes the construction
|
||||||
line. For these reasons, the COMET collaboration considers a staged approach
|
of the COMET beam line. For these reasons, the COMET collaboration considers
|
||||||
with the first stage, so called COMET Phase-I, with a shorter muon
|
to carry out the experiment in two stages. The first stage, so called COMET
|
||||||
transportation solenoid, up to the first 90\si{\degree}.
|
Phase-I, with a shorter muon transportation solenoid, up to the first
|
||||||
|
90\si{\degree}.
|
||||||
|
|
||||||
%\begin{wrapfigure}{r}{0.5\textwidth}
|
%\begin{wrapfigure}{r}{0.5\textwidth}
|
||||||
%\centering
|
%\centering
|
||||||
@@ -531,8 +563,8 @@ transportation solenoid, up to the first 90\si{\degree}.
|
|||||||
%\end{wrapfigure}
|
%\end{wrapfigure}
|
||||||
\begin{SCfigure}
|
\begin{SCfigure}
|
||||||
\centering
|
\centering
|
||||||
\caption{Lay out of the COMET Phase-I, the target and detector solenoid are
|
\caption{Layout of the COMET Phase-I, the target and detector solenoid are
|
||||||
placed after the first 90\si{\degree}~bend.}
|
placed after the end of the first \ang{90} bend.}
|
||||||
\includegraphics[width=0.4\textwidth]{figs/comet_phase1_layout}
|
\includegraphics[width=0.4\textwidth]{figs/comet_phase1_layout}
|
||||||
\label{fig:comet_phase1_layout}
|
\label{fig:comet_phase1_layout}
|
||||||
\end{SCfigure}
|
\end{SCfigure}
|
||||||
@@ -545,11 +577,11 @@ The COMET Phase-I has two major goals:
|
|||||||
and physics background from muon DIO. Straw tube trackers and crystal
|
and physics background from muon DIO. Straw tube trackers and crystal
|
||||||
calorimeter with the same technology in the full COMET will be used, thus
|
calorimeter with the same technology in the full COMET will be used, thus
|
||||||
these detectors can be regarded as the final prototype.
|
these detectors can be regarded as the final prototype.
|
||||||
\item Search for \mueconv with an intermediate sensitivity of \sn{3.1}{-15},
|
\item Search for \mueconv with an intermediate single event sensitivity of
|
||||||
a two orders of magnitude improvement from the SINDRUM-II limit. To realise
|
\num{3.1E-15}, a two orders of magnitude improvement from the SINDRUM-II
|
||||||
this goal, two options for detectors are being considered, either a reused
|
limit. Another dedicated detector system (described in
|
||||||
of the detectors for background measurements, or a dedicated detector.
|
\cref{sub:detectors_for_mueconv_search_in_the_phase_i}) is considered for
|
||||||
The latter will be described in detail later.
|
this physics measurement.
|
||||||
\end{enumerate}
|
\end{enumerate}
|
||||||
|
|
||||||
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
|
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
|
||||||
@@ -558,11 +590,11 @@ The COMET Phase-I has two major goals:
|
|||||||
Proton beam for the Phase-I differs only in beam power compares to that of the
|
Proton beam for the Phase-I differs only in beam power compares to that of the
|
||||||
full COMET. It is estimated that a beam power of
|
full COMET. It is estimated that a beam power of
|
||||||
3.2~\si{\kilo\watt}~$=$~8~\si{\giga\electronvolt}~$\times$~0.4~\si{\micro\ampere}~(or
|
3.2~\si{\kilo\watt}~$=$~8~\si{\giga\electronvolt}~$\times$~0.4~\si{\micro\ampere}~(or
|
||||||
\sn{2.5}{12} protons\si{\per\second}) will be enough for beam properties
|
\sn{2.5}{12} protons per second) will be enough for beam properties
|
||||||
study and achieving the physics goal of this stage.
|
study and achieving the physics goal of this stage.
|
||||||
Starting from a lower intensity is also suitable for performing accelerator
|
Starting from a lower intensity is also suitable for performing accelerator
|
||||||
studies that are needed to realise 8~\si{\giga\electronvolt} beam extraction from
|
studies that are needed to realise 8~\si{\giga\electronvolt} beam extraction
|
||||||
the J-PARC main ring.
|
from the J-PARC main ring.
|
||||||
% subsection proton_beam_for_the_comet_phase_i (end)
|
% subsection proton_beam_for_the_comet_phase_i (end)
|
||||||
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
|
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
|
||||||
\subsection{Pion production and transportation solenoids}
|
\subsection{Pion production and transportation solenoids}
|
||||||
@@ -579,7 +611,7 @@ A correction dipole filed of 0.05 T is also applied to improve the pion yield.
|
|||||||
The pion/muon beam line for COMET Phase-I consists of the pion capture solenoid
|
The pion/muon beam line for COMET Phase-I consists of the pion capture solenoid
|
||||||
section (CS), muon transport solenoid section (TS) up to the first
|
section (CS), muon transport solenoid section (TS) up to the first
|
||||||
90\si{\degree}~bending, and a set of matching solenoids (see
|
90\si{\degree}~bending, and a set of matching solenoids (see
|
||||||
Figure~\ref{fig:comet_phase1_magnets}). At the end of the muon beam line, the
|
\cref{fig:comet_phase1_magnets}). At the end of the muon beam line, the
|
||||||
detectors and the detector solenoid (DS) are installed. To reduce beam
|
detectors and the detector solenoid (DS) are installed. To reduce beam
|
||||||
backgrounds, a beam collimator is placed upstream of the detector solenoid.
|
backgrounds, a beam collimator is placed upstream of the detector solenoid.
|
||||||
\begin{figure}[htb]
|
\begin{figure}[htb]
|
||||||
@@ -599,7 +631,7 @@ backgrounds, a beam collimator is placed upstream of the detector solenoid.
|
|||||||
As mentioned, two types of detectors are considered for physics measurements in
|
As mentioned, two types of detectors are considered for physics measurements in
|
||||||
the Phase-I. The dedicated detector system consists of a cylindrical drift
|
the Phase-I. The dedicated detector system consists of a cylindrical drift
|
||||||
chamber (CDC), a trigger hodoscope, a proton absorber and a detector solenoid
|
chamber (CDC), a trigger hodoscope, a proton absorber and a detector solenoid
|
||||||
(Figure~\ref{fig:comet_phase1_cydet}).
|
(\cref{fig:comet_phase1_cydet}).
|
||||||
The whole system is referred as cylindrical detector system (CyDet) in the
|
The whole system is referred as cylindrical detector system (CyDet) in the
|
||||||
COMET's documentation. The CyDet has advantages that low momentum particles for
|
COMET's documentation. The CyDet has advantages that low momentum particles for
|
||||||
the stopping target will not reach the detector, thus the hit rates are kept
|
the stopping target will not reach the detector, thus the hit rates are kept
|
||||||
@@ -614,26 +646,28 @@ CyDet.
|
|||||||
\label{fig:comet_phase1_cydet}
|
\label{fig:comet_phase1_cydet}
|
||||||
\end{figure}
|
\end{figure}
|
||||||
|
|
||||||
|
\subsubsection{CDC configuration}
|
||||||
|
\label{ssub:CDC_configuration}
|
||||||
The CDC is the main tracking detector that provides information for
|
The CDC is the main tracking detector that provides information for
|
||||||
reconstruction of charged particle tracks and measuring their momenta. The key
|
reconstruction of charged particle tracks and measuring their momenta. The key
|
||||||
parameters for the CDC are listed in the
|
parameters for the CDC are listed in the
|
||||||
Table~\ref{tab:comet_phase1_cdc_params}.
|
\cref{tab:comet_phase1_cdc_params}.
|
||||||
Trigger hodoscopes are placed at both upstream and downstream ends of the CDC.
|
Trigger hodoscopes are placed at both upstream and downstream ends of the CDC.
|
||||||
An absorber is placed concentrically with respect to the CDC axis to
|
A proton absorber is placed concentrically with respect to the CDC axis to
|
||||||
reduce potential high rates caused by protons emitted after nuclear muon
|
reduce potential high rates caused by protons emitted after nuclear muon
|
||||||
capture in the stopping target.
|
capture in the stopping target.
|
||||||
|
|
||||||
The CDC covers the region
|
The CDC covers the region
|
||||||
from \SIrange{500}{831}{\milli\meter}~in the radial direction. The length
|
from \SIrange{500}{831}{\milli\meter}~in the radial direction. The length
|
||||||
of the CDC is 1500~\si{\milli\meter}. The inner wall is made of
|
of the CDC is 1500~\si{\milli\meter}. The inner wall is made of
|
||||||
a 100~\si{\micro\meter}-thick aluminised Mylar. The end-plates will be conical
|
a 500-\si{um}-thick carbon fibre reinforced plastic (CFRP, density
|
||||||
in shape and about 10~\si{\milli\meter}-thick to support the feedthroughs. The outer
|
\SI{1.57}{\gram\per\cubic\m}). The end-plates will
|
||||||
wall is
|
be conical in shape and about 10-\si{\mm}-thick to support the
|
||||||
made of 5~\si{\milli\meter}~carbon fibre reinforced plastic (CFRP).
|
feedthroughs. The outer wall is made of 5-\si{\mm} CFRP.
|
||||||
|
|
||||||
The CDC is arranged in 20 concentric sense layers with alternating positive and
|
The CDC is arranged in 20 concentric sense layers with alternating positive and
|
||||||
negative stereo angles. The sense wires are made of gold-plated tungsten,
|
negative stereo angles. The sense wires are made of gold-plated tungsten,
|
||||||
30~\si{\micro\meter} in diameter, tensioned to 50~\si{\gram}. The field wires
|
\SI{25}{\um} in diameter, tensioned to \SI{50}{\gram}. The field wires
|
||||||
are uncoated aluminium wires with a diameter of 80~\si{\micro\meter}, at the same
|
are uncoated aluminium wires with a diameter of 80~\si{\micro\meter}, at the same
|
||||||
tension of \SI{50}{\gram}. A high voltage of $1700\sim1900$~\si{\volt} will be
|
tension of \SI{50}{\gram}. A high voltage of $1700\sim1900$~\si{\volt} will be
|
||||||
applied to the sense wires with the field wires at ground potential, giving an
|
applied to the sense wires with the field wires at ground potential, giving an
|
||||||
@@ -674,37 +708,72 @@ these configurations, an intrinsic momentum resolution of
|
|||||||
\label{tab:comet_phase1_cdc_params}
|
\label{tab:comet_phase1_cdc_params}
|
||||||
\end{table}
|
\end{table}
|
||||||
|
|
||||||
The maximum usable muon beam intensity will be limited by the detector hit
|
\subsubsection{Hit rate on the CDC}
|
||||||
|
\label{ssub:hit_rate_on_the_cdc}
|
||||||
|
The maximal usable muon beam intensity will be limited by the detector hit
|
||||||
occupancy. Charge particles with transversal momentum greater than 70
|
occupancy. Charge particles with transversal momentum greater than 70
|
||||||
\si{\mega\electronvolt\per\cc} are expected to reach the CDC. Those particles are:
|
\si{\mega\electronvolt\per\cc} are expected to reach the CDC. Those include:
|
||||||
protons emitted from nuclear muon capture, and electrons from muon decay in
|
protons emitted from nuclear muon capture, and electrons from muon decay in
|
||||||
orbit. It is calculated that the hit rate due to proton emission dominates,
|
orbit (DIO). It is calculated that the hit rate due to proton emission dominates,
|
||||||
where the highest rate is 11~\si{\kilo\hertz\per}cell compares to
|
where the highest rate is \SI{11}{\kHz\per}cell compares to
|
||||||
5~\si{\kilo\hertz\per}
|
\SI{5}{\kHz\per}cell contributing from DIO electrons. Another potential issue
|
||||||
cell contributing from DIO electrons. Another potential issue caused by protons
|
%%TODO check the hit rates against TDR
|
||||||
is the ageing effect on the CDC as they leave about a 100 times larger
|
caused by protons is the ageing effect on the CDC as they leave about a 100
|
||||||
|
times larger
|
||||||
energy deposit than the minimum ionisation particles.
|
energy deposit than the minimum ionisation particles.
|
||||||
|
%%TODO integration charge ...
|
||||||
|
|
||||||
For those reasons, we plan to install an absorber to reduce the rate of protons
|
For those reasons, we plan to install a proton absorber to reduce the rate of
|
||||||
reaching the CDC. However, there is no experimental data available for the rate
|
protons reaching the CDC. However, there is no experimental data available for
|
||||||
|
the rate
|
||||||
of protons emitted after muon capture in aluminium. In the design of the COMET
|
of protons emitted after muon capture in aluminium. In the design of the COMET
|
||||||
Phase-I, we use a conservative estimation of the rate of protons from energy
|
Phase-I, we use a conservative estimation of the rate of protons from energy
|
||||||
spectrum of charged particles emitted from muon capture in
|
spectrum of charged particles emitted from muon capture in
|
||||||
$^{28}$Si~\cite{SobottkaWills.1968}. The baseline design for the proton
|
$^{28}$Si~\cite{SobottkaWills.1968}. The baseline design for the proton
|
||||||
absorber is 1.0~\si{\milli\meter}-thick CFRP, which contributes
|
absorber is 0.5~\si{\milli\meter}-thick CFRP, making the total thickness
|
||||||
195~\si{\kilo\electronvolt\per\cc} to the momentum resolution of reconstructed
|
of material before the sensitive region is \SI{1.0}{\mm} in CFRP. In this
|
||||||
track.
|
configuration, the inner wall and the proton absorber contribute a spread of
|
||||||
|
\SI{167}{\keV\per\cc} to the momentum of a \mueconv signal electron. This
|
||||||
|
figure is a little below the spread cause by multiple scatterings on the
|
||||||
|
chamber gas at \SI{197}{\keV\per\cc}.
|
||||||
|
The impact of the proton absorber on the CDC's hit rate and momentum
|
||||||
|
resolution is summarised in \cref{tab:comet_absorber_impact}.
|
||||||
|
\begin{table}[htb]
|
||||||
|
\begin{center}
|
||||||
|
\begin{tabular}{@{}cccc@{}}
|
||||||
|
\toprule
|
||||||
|
\textbf{Absorber }& \textbf{Total CFRP }&\textbf{Proton }&
|
||||||
|
\textbf{$\Delta p$}\\
|
||||||
|
\textbf{thickness }& \textbf{thickness }&\textbf{hit rate }& \\
|
||||||
|
(\si{\mm}) &(\si{\mm}) & (\si{\kHz}) & (\si{\keV\per\cc}) \\
|
||||||
|
\midrule
|
||||||
|
0 & 0.5 & 130 & 131 \\
|
||||||
|
0.5 & 1.0 & 34 & 167 \\
|
||||||
|
1.0 & 1.5 & 11 & 195 \\
|
||||||
|
1.5 & 2.0 & 6 & 252 \\
|
||||||
|
\bottomrule
|
||||||
|
\end{tabular}
|
||||||
|
\end{center}
|
||||||
|
\caption{Hit rates and contributions to momentum spread of the proton
|
||||||
|
absorber and inner wall of the CDC. The resolutions are calculated for
|
||||||
|
mono-energetic electrons of \SI{104.96}{\MeV\per\cc}.}
|
||||||
|
\label{tab:comet_absorber_impact}
|
||||||
|
\end{table}
|
||||||
|
|
||||||
In order to obtain a better understanding of the protons emission, and then
|
In order to obtain a better understanding of the protons emission, and then
|
||||||
further optimisation of the CDC, a dedicated experiment to measure proton
|
further optimisation of the CDC, a dedicated experiment to measure proton
|
||||||
emission rate and energy spectrum is being carried out at PSI. This experiment
|
emission rate and energy spectrum is being carried out at PSI. This experiment
|
||||||
is described in detail in next chapters.
|
is described in detail in next chapters.
|
||||||
|
|
||||||
|
It should be noted that the proton hit rate is not a problem for the COMET
|
||||||
|
Phase-II where the additional electron transport solenoid would removed all
|
||||||
|
protons emitted.
|
||||||
% subsection detectors_for_mueconv_search_in_the_phase_i (end)
|
% subsection detectors_for_mueconv_search_in_the_phase_i (end)
|
||||||
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
|
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
|
||||||
\subsection{Sensitivity of the \mueconv search in the Phase-I}
|
\subsection{Sensitivity of the \mueconv search in the Phase-I}
|
||||||
\label{sub:sensitivity_of_the_mueconv_search_in_the_phase_i}
|
\label{sub:sensitivity_of_the_mueconv_search_in_the_phase_i}
|
||||||
The SES for the Phase-I is given by
|
The SES for the Phase-I is given by
|
||||||
the Equation~\ref{eq:mue_sensitivity}. Using $N_{\mu} = 1.3\times 10^{16}$,
|
the \eqref{eq:mue_sensitivity}. Using $N_{\mu} = 1.3\times 10^{16}$,
|
||||||
$f_{\textrm{cap}} = 0.61$, and $A_e = 0.043$ from MC study for the Phase-I, the
|
$f_{\textrm{cap}} = 0.61$, and $A_e = 0.043$ from MC study for the Phase-I, the
|
||||||
SES becomes:
|
SES becomes:
|
||||||
\begin{equation}
|
\begin{equation}
|
||||||
@@ -715,10 +784,11 @@ SES becomes:
|
|||||||
\subsection{Time line of the COMET Phase-I and Phase-II}
|
\subsection{Time line of the COMET Phase-I and Phase-II}
|
||||||
\label{sub:time_line_of_the_phase_i}
|
\label{sub:time_line_of_the_phase_i}
|
||||||
We are now in the construction stage of the COMET Phase-I, which is planned to
|
We are now in the construction stage of the COMET Phase-I, which is planned to
|
||||||
be finished by the end of 2016. We will carry out engineering run in 2016,
|
be finished in the middle of 2016. We will carry out engineering run in the
|
||||||
|
second half of 2016,
|
||||||
and subsequently, physics run in 2017. A beam time of 90 days is expected to
|
and subsequently, physics run in 2017. A beam time of 90 days is expected to
|
||||||
achieve the goal sensitivity of the Phase-I. An anticipated schedule for the
|
achieve the goal sensitivity of the Phase-I. An anticipated schedule for the
|
||||||
COMET, both Phase-I and Phase-II, is shown in Figure~\ref{fig:sched}.
|
COMET, both Phase-I and Phase-II, is shown in \cref{fig:sched}.
|
||||||
\begin{figure}[tbh]
|
\begin{figure}[tbh]
|
||||||
\centering
|
\centering
|
||||||
\includegraphics[width=0.8\textwidth]{figs/sched}
|
\includegraphics[width=0.8\textwidth]{figs/sched}
|
||||||
|
|||||||
@@ -5,19 +5,19 @@
|
|||||||
\thispagestyle{empty}
|
\thispagestyle{empty}
|
||||||
As mentioned earlier, the emission rate of protons
|
As mentioned earlier, the emission rate of protons
|
||||||
following nuclear muon capture on aluminium is of interest to the COMET Phase-I
|
following nuclear muon capture on aluminium is of interest to the COMET Phase-I
|
||||||
since protons can cause a very high hit rate on the proposed cylindrical drift
|
since protons could cause a very high hit rate on the proposed cylindrical drift
|
||||||
chamber. Another \mueconv experiment, namely Mu2e at Fermilab, which aims at
|
chamber. Another \mueconv experiment, namely Mu2e at Fermilab, which aims at
|
||||||
a similar goal sensitivity as that of the COMET, also shares the same interest
|
a similar goal sensitivity as that of the COMET, also shares the same interest
|
||||||
on proton emission. Therefore, a joint COMET-Mu2e project was formed to carry
|
on proton emission. Therefore, a joint COMET-Mu2e project was formed to carry
|
||||||
out the measurement of proton, and other charged particles, emission. The
|
out the measurement of proton, and other charged particles, emission. The
|
||||||
experiment, so-called AlCap, has been proposed and approved to be carried out
|
experiment, so-called AlCap, has been proposed and approved to be carried out
|
||||||
at PSI in 2013~\cite{AlCap.2013}. In addition to proton, the AlCap
|
at PSI in 2013~\cite{AlCap.2013}. In addition to proton emission, the AlCap
|
||||||
experiment will also measure:
|
experiment will also measure:
|
||||||
\begin{itemize}
|
\begin{itemize}
|
||||||
\item neutrons, because they can cause backgrounds on other detectors and
|
\item neutron emission, because neutrons could cause backgrounds on the other
|
||||||
damage the front-end electronics; and
|
detectors and damage the front-end electronics; and
|
||||||
\item photons, since they provide ways to normalise number of stopped muons
|
\item photon emission to validate the normalisation number of stopped
|
||||||
in the stopping target.
|
muons in the stopping target.
|
||||||
\end{itemize}
|
\end{itemize}
|
||||||
|
|
||||||
The emission of particles following muon capture in nuclei
|
The emission of particles following muon capture in nuclei
|
||||||
@@ -27,7 +27,7 @@ energy nuclear physics'' where it is postulated that the weak interaction is
|
|||||||
well understood and muons are used as an additional probe to investigate the
|
well understood and muons are used as an additional probe to investigate the
|
||||||
nuclear structure~\cite{Singer.1974, Measday.2001}.
|
nuclear structure~\cite{Singer.1974, Measday.2001}.
|
||||||
Unfortunately, the proton emission rate for aluminium in the energy range of
|
Unfortunately, the proton emission rate for aluminium in the energy range of
|
||||||
interest is not available. This chapter reviews the current knowledge on
|
interest has not been measured. This chapter reviews the current knowledge on
|
||||||
emission of particles with emphasis on proton.
|
emission of particles with emphasis on proton.
|
||||||
%theoretically and experimentally, hence serves as the motivation for the AlCap
|
%theoretically and experimentally, hence serves as the motivation for the AlCap
|
||||||
%experiment.
|
%experiment.
|
||||||
@@ -66,21 +66,20 @@ emission of particles with emphasis on proton.
|
|||||||
Theoretically, the capturing process can be described in the following
|
Theoretically, the capturing process can be described in the following
|
||||||
stages~\cite{FermiTeller.1947, WuWilets.1969}:
|
stages~\cite{FermiTeller.1947, WuWilets.1969}:
|
||||||
\begin{enumerate}
|
\begin{enumerate}
|
||||||
\item High to low (a few \si{\kilo\electronvolt}) energy: the muon velocity are
|
\item High to low (a few \si{\kilo\electronvolt}) energy: the muon velocity
|
||||||
greater than the velocity of the valence electrons of the atom. Slowing
|
are greater than the velocity of the valence electrons of the atom. Slowing
|
||||||
down process is similar to that of fast heavy charged particles. It takes
|
down process is similar to that of fast heavy charged particles. It takes
|
||||||
about \sn{}{-9} to \sn{}{-10} \si{\second}~to slow down from a relativistic
|
about \SIrange{E-10}{E-9}{\s} to slow down from a relativistic
|
||||||
\sn{}{8}~\si{\electronvolt}~energy to 2000~\si{\electronvolt}~in condensed matter,
|
\SI{E8}{\eV} energy to \SI{2000}{\eV} in condensed matter,
|
||||||
and about 1000 times as long in air.
|
and about 1000 times as long in air.
|
||||||
\item Low energy to rest: in this phase, the muon velocity is less than that
|
\item Low energy to rest: in this phase, the muon velocity is less than that
|
||||||
of the valence electrons, the muon is considered to be moving inside
|
of the valence electrons, the muon is considered to be moving inside
|
||||||
a degenerate electron gas. The muon rapidly comes to a stop either in
|
a degenerate electron gas. The muon rapidly comes to a stop either in
|
||||||
condensed matters ($\sim$\sn{}{-13}~\si{\second}) or in gases ($\sim$\sn{}{-9}
|
condensed matters ($\simeq\SI{E-13}{\s}$) or in gases ($\simeq\SI{E-9}{\s}$).
|
||||||
\si{\second}).
|
\item Atomic capture: when the muon has no kinetic energy, it is captured by
|
||||||
\item Atomic capture: the muon has no kinetic energy, it is captured by the
|
a host atom into one of high orbital states, forming a muonic atom. The
|
||||||
host atom into one of high orbital states, forming a muonic atom. The
|
|
||||||
distribution of initial states is not well known. The details depend on
|
distribution of initial states is not well known. The details depend on
|
||||||
whether the material is a solid or gas, insulator or material
|
whether the material is a solid or gas, insulator or metal.
|
||||||
\item Electromagnetic cascade: since all muonic states are unoccupied, the
|
\item Electromagnetic cascade: since all muonic states are unoccupied, the
|
||||||
muon cascades down to states of low energy. The transition is accompanied
|
muon cascades down to states of low energy. The transition is accompanied
|
||||||
by the emission of Auger electrons or characteristic X-rays, or excitation
|
by the emission of Auger electrons or characteristic X-rays, or excitation
|
||||||
@@ -88,10 +87,12 @@ stages~\cite{FermiTeller.1947, WuWilets.1969}:
|
|||||||
state, 1S, from the instant of its atomic capture is
|
state, 1S, from the instant of its atomic capture is
|
||||||
$\sim$\sn{}{-14}\si{\second}.
|
$\sim$\sn{}{-14}\si{\second}.
|
||||||
\item Muon disappearance: after reaching the 1S state, the muons either
|
\item Muon disappearance: after reaching the 1S state, the muons either
|
||||||
decays with a half-life of \sn{2.2}{-6}~\si{\second}~or gets captured by the
|
decays or gets captured by the nucleus. The possibility to be captured
|
||||||
nucleus. In hydrogen, the capture to decay probability ratio is about
|
effectively shortens the mean lifetime of negative muons stopped in
|
||||||
\sn{4}{-4}. Around $Z=11$, the capture probability is roughly equal to the
|
a material. In hydrogen, the capture to decay
|
||||||
decay probability. In heavy nuclei ($Z\sim50$), the ratio of capture to
|
probability ratio is about \sn{4}{-4}. Around $Z=11$, the capture
|
||||||
|
probability is roughly equal to the
|
||||||
|
decay probability. In heavy nuclei ($Z\geq$), the ratio of capture to
|
||||||
decay probabilities is about 25.
|
decay probabilities is about 25.
|
||||||
|
|
||||||
The K-shell muon will be $m_\mu/m_e \simeq 207$ times nearer the nucleus
|
The K-shell muon will be $m_\mu/m_e \simeq 207$ times nearer the nucleus
|
||||||
@@ -108,24 +109,25 @@ stages~\cite{FermiTeller.1947, WuWilets.1969}:
|
|||||||
\label{sec:nuclear_muon_capture}
|
\label{sec:nuclear_muon_capture}
|
||||||
The nuclear capture process is written as:
|
The nuclear capture process is written as:
|
||||||
\begin{equation}
|
\begin{equation}
|
||||||
\mu^- + A(N, Z) \rightarrow A(N, Z-1) + \nu_\mu
|
\mu^- + A(N, Z) \rightarrow A(N, Z-1) + \nu_\mu \,.
|
||||||
\label{eq:mucap_general}
|
\label{eq:mucap_general}
|
||||||
\end{equation}
|
\end{equation}
|
||||||
The resulting nucleus can be either in its ground state or in an excited state.
|
The resulting nucleus can be either in its ground state or in an excited state.
|
||||||
The reaction is manifestation of the elementary ordinary muon capture on the
|
The reaction is manifestation of the elementary ordinary muon capture on the
|
||||||
proton:
|
proton:
|
||||||
\begin{equation}
|
\begin{equation}
|
||||||
\mu^- + p \rightarrow n + \nu_\mu
|
\mu^- + p \rightarrow n + \nu_\mu \,.
|
||||||
\label{eq:mucap_proton}
|
\label{eq:mucap_proton}
|
||||||
\end{equation}
|
\end{equation}
|
||||||
If the resulting nucleus at is in an excited state, it could cascade to lower
|
If the resulting nucleus at is in an excited state, it could cascade down to
|
||||||
states by emitting light particles and leaving a residual heavy nucleus. The
|
lower states by emitting light particles and gamma rays, leaving a residual
|
||||||
light particles are mostly neutrons and (or) photons. Neutrons can also be
|
heavy nucleus. The light particles are mostly neutrons and (or) photons.
|
||||||
|
Neutrons can also be
|
||||||
directly knocked out of the nucleus via the reaction~\eqref{eq:mucap_proton}.
|
directly knocked out of the nucleus via the reaction~\eqref{eq:mucap_proton}.
|
||||||
Charged particles are emitted with probabilities of a few percent, and are
|
Charged particles are emitted with probabilities of a few percent, and are
|
||||||
mainly protons, deuterons and alphas have been observed in still smaller
|
mainly protons, deuterons and alphas have been observed in still smaller
|
||||||
probabilities. Because of the central interest on proton emission, it is covered
|
probabilities. Because of the central interest on proton emission, it is
|
||||||
in a separated section.
|
discussed in a separated section.
|
||||||
|
|
||||||
\subsection{Muon capture on the proton}
|
\subsection{Muon capture on the proton}
|
||||||
\label{sub:muon_capture_on_proton}
|
\label{sub:muon_capture_on_proton}
|
||||||
@@ -138,10 +140,10 @@ in a separated section.
|
|||||||
%$\mu p$ atom is quite active, so it is likely to form muonic molecules like
|
%$\mu p$ atom is quite active, so it is likely to form muonic molecules like
|
||||||
%$p\mu p$, $p\mu d$ and $p\mu t$, which complicate the study of weak
|
%$p\mu p$, $p\mu d$ and $p\mu t$, which complicate the study of weak
|
||||||
%interaction.
|
%interaction.
|
||||||
The underlying interaction in proton capture in Equation~\eqref{eq:mucap_proton}
|
The underlying interaction in proton capture in~\eqref{eq:mucap_proton}
|
||||||
at nucleon level and quark level
|
at nucleon level and quark level
|
||||||
are depicted in the Figure~\ref{fig:feyn_protoncap}. The flow of time is from
|
are depicted in \cref{fig:feyn_protoncap}. The direction of time is
|
||||||
the left to the right hand side, as an incoming muon and an up quark
|
from the left to the right hand side, as an incoming muon and an up quark
|
||||||
exchange a virtual $W$ boson to produce a muon neutrino and a down quark, hence
|
exchange a virtual $W$ boson to produce a muon neutrino and a down quark, hence
|
||||||
a proton transforms to a neutron.
|
a proton transforms to a neutron.
|
||||||
|
|
||||||
@@ -156,7 +158,10 @@ a proton transforms to a neutron.
|
|||||||
\end{figure}
|
\end{figure}
|
||||||
|
|
||||||
The four-momentum transfer in the interaction is fixed at
|
The four-momentum transfer in the interaction is fixed at
|
||||||
$q^2 = (q_n - q_p)^2 = -0.88m_\mu^2 \ll m_W^2$. The smallness of the momentum
|
\begin{equation}
|
||||||
|
q^2 = (q_n - q_p)^2 = -0.88m_\mu^2 \ll m_W^2\,.
|
||||||
|
\end{equation}
|
||||||
|
The smallness of the momentum
|
||||||
transfer in comparison to the $W$ boson's mass makes it possible to treat the
|
transfer in comparison to the $W$ boson's mass makes it possible to treat the
|
||||||
interaction as a four-fermion interaction with Lorentz-invariant transition
|
interaction as a four-fermion interaction with Lorentz-invariant transition
|
||||||
amplitude:
|
amplitude:
|
||||||
@@ -181,14 +186,14 @@ is factored out in Eq.~\eqref{eq:4fermion_trans_amp}):
|
|||||||
\label{eq:weakcurrent_ud}
|
\label{eq:weakcurrent_ud}
|
||||||
\end{equation}
|
\end{equation}
|
||||||
If the nucleon were point-like, the nucleon current would have the same form as
|
If the nucleon were point-like, the nucleon current would have the same form as
|
||||||
in Eq.~\eqref{eq:weakcurrent_ud} with suitable wavefunctions of the proton and
|
in \eqref{eq:weakcurrent_ud} with suitable wavefunctions of the proton and
|
||||||
neutron. But that is not the case, in order to account for the complication of
|
neutron. But that is not the case, in order to account for the complication of
|
||||||
the nucleon, the current must be modified by six real form factors
|
the nucleon, the current must be modified by six real form factors
|
||||||
$g_i(q^2), i = V, M, S, A, T, P$:
|
$g_i(q^2), i = V, M, S, A, T, P$:
|
||||||
\begin{align}
|
\begin{align}
|
||||||
J_\alpha &= i\bar{\psi}_n(V^\alpha - A^\alpha)\psi_p,\\
|
J_\alpha &= i\bar{\psi}_n(V^\alpha - A^\alpha)\psi_p\,,\\
|
||||||
V^\alpha &= g_V (q^2) \gamma^\alpha + i \frac{g_M(q^2)}{2m_N}
|
V^\alpha &= g_V (q^2) \gamma^\alpha + i \frac{g_M(q^2)}{2m_N}
|
||||||
\sigma^{\alpha\beta} q_\beta + g_S(q^2)q^\alpha,\\
|
\sigma^{\alpha\beta} q_\beta + g_S(q^2)q^\alpha\,, \textrm{ and}\\
|
||||||
A^\alpha &= g_A(q^2)\gamma^\alpha \gamma_5 + ig_T(q^2)
|
A^\alpha &= g_A(q^2)\gamma^\alpha \gamma_5 + ig_T(q^2)
|
||||||
\sigma^{\alpha\beta} q_\beta\gamma_5 + \frac{g_P(q^2)}{m_\mu}\gamma_5
|
\sigma^{\alpha\beta} q_\beta\gamma_5 + \frac{g_P(q^2)}{m_\mu}\gamma_5
|
||||||
q^\alpha,
|
q^\alpha,
|
||||||
@@ -223,7 +228,7 @@ muonic molecules $p\mu p$, $d\mu p$ and $t\mu p$, $g_P$ is the least
|
|||||||
well-defined form factor. Only recently, it is measured with a reasonable
|
well-defined form factor. Only recently, it is measured with a reasonable
|
||||||
precision~\cite{AndreevBanks.etal.2013a}.
|
precision~\cite{AndreevBanks.etal.2013a}.
|
||||||
The values of the six form factors at $q^2 = -0.88m^2_\mu$ are listed in
|
The values of the six form factors at $q^2 = -0.88m^2_\mu$ are listed in
|
||||||
Table~\ref{tab:formfactors}.
|
\cref{tab:formfactors}.
|
||||||
\begin{table}[htb]
|
\begin{table}[htb]
|
||||||
\begin{center}
|
\begin{center}
|
||||||
\begin{tabular}{l l l}
|
\begin{tabular}{l l l}
|
||||||
@@ -259,35 +264,8 @@ $\Lambda_t$ is given by:
|
|||||||
where $\Lambda_c$ and $\Lambda_d$ are partial capture rate and decay rate,
|
where $\Lambda_c$ and $\Lambda_d$ are partial capture rate and decay rate,
|
||||||
respectively, and $Q$ is the Huff factor, which is corrects for the fact that
|
respectively, and $Q$ is the Huff factor, which is corrects for the fact that
|
||||||
muon decay rate in a bound state is reduced because of the binding energy
|
muon decay rate in a bound state is reduced because of the binding energy
|
||||||
reduces the available energy.
|
reduces the available energy. The correction begins to be significant for
|
||||||
%The total capture rates for several selected
|
$Z\geq 40$ as shown in \cref{tab:total_capture_rate}.
|
||||||
%elements are compiled by Measday~\cite{Measday.2001},
|
|
||||||
%and reproduced in
|
|
||||||
%Table~\ref{tab:total_capture_rate}.
|
|
||||||
%\begin{table}[htb]
|
|
||||||
%\begin{center}
|
|
||||||
%\begin{tabular}{l l r@{.}l r@{.}l@{$\pm$}l l}
|
|
||||||
%\toprule
|
|
||||||
%\textbf{$Z$ ($Z_{\textrm{eff}}$)} &
|
|
||||||
%\textbf{Element} &
|
|
||||||
%\multicolumn{2}{l}{\textbf{Mean lifetime}} &
|
|
||||||
%\multicolumn{3}{l}{\textbf{Capture rate}} &
|
|
||||||
%\textbf{Huff factor}\\
|
|
||||||
%& &
|
|
||||||
%\multicolumn{2}{c}{\textbf{(\nano\second)}} &
|
|
||||||
%\multicolumn{3}{l}{\textbf{$\times 10^3$ (\reciprocal\second)}} &\\
|
|
||||||
%\midrule
|
|
||||||
%1 (1.00) & $^1$H & 2194&90 $\pm$0.07 & 0&450 &0.020 & 1.00\\
|
|
||||||
%& $^2$H & 2194&53 $\pm$0.11 & 0&470 &0.029 & \\
|
|
||||||
%2 (1.98) & $^3$He & 2186&70 $\pm$0.10 & 2&15 &0.020 & 1.00\\
|
|
||||||
%& $^4$He & 2195&31 $\pm$0.05 & 0&470&0.029 & \\
|
|
||||||
%\bottomrule
|
|
||||||
%\end{tabular}
|
|
||||||
%\end{center}
|
|
||||||
%\caption{Total capture rate of the muon in nuclei for several selected
|
|
||||||
%elements, compiled by Measday~\cite{Measday.2001}}
|
|
||||||
%\label{tab:total_capture_rate}
|
|
||||||
%\end{table}
|
|
||||||
|
|
||||||
Theoretically, it is assumed that the muon capture rate on a proton of the
|
Theoretically, it is assumed that the muon capture rate on a proton of the
|
||||||
nucleus depends only on the overlap of the muon with the nucleus. For light
|
nucleus depends only on the overlap of the muon with the nucleus. For light
|
||||||
@@ -312,13 +290,56 @@ reduced because a smaller phase-space in the nuclear muon capture compares to
|
|||||||
that of a nucleon; and $X_2 = 3.125$ takes into account the fact that it is
|
that of a nucleon; and $X_2 = 3.125$ takes into account the fact that it is
|
||||||
harder for protons to transforms into neutrons due to the Pauli exclusion
|
harder for protons to transforms into neutrons due to the Pauli exclusion
|
||||||
principle in heavy nuclei where there are more neutrons than protons.
|
principle in heavy nuclei where there are more neutrons than protons.
|
||||||
|
|
||||||
|
The total capture rates for several selected elements are compiled by
|
||||||
|
Measday~\cite{Measday.2001}, and reproduced in \cref{tab:total_capture_rate}.
|
||||||
|
\begin{table}[htb]
|
||||||
|
\begin{center}
|
||||||
|
\begin{tabular}{r c S S S}
|
||||||
|
\toprule
|
||||||
|
$Z (Z_{eff})$ & \textbf{Element} & \textbf{Mean lifetime (\si{\ns})}
|
||||||
|
& \textbf{Capture rate ($\times 10^{-3}$ \si{\ns})} & \textbf{Huff factor}\\
|
||||||
|
|
||||||
|
%& & \textbf{(\si{\ns})} & \textbf{($\times 10^{-3} \si{\Hz}$)} &\\
|
||||||
|
\midrule
|
||||||
|
1 (1.00)& $^{1}$H & 2194.90 (7)& 0.450 (20)& 1.00 \\
|
||||||
|
& $^{2}$H & 2194.53 (11)& 0.470 (29)& \\
|
||||||
|
2 (1.98)& $^{3}$He & 2186.70 (10)& 2.15 (2)& 1.00\\
|
||||||
|
& $^{4}$He & 2195.31 (5)& 0.356 (26)&\\
|
||||||
|
3 (2.94)& $^{6}$Li & 2175.3 (4)& 4.68 (12)& 1.00 \\
|
||||||
|
& $^{7}$Li & 2186.8 (4)& 2.26 (12)& \\
|
||||||
|
4 (3.89)& $^{9}$Be & 2168 (3)& 6.1 (6)& 1.00 \\
|
||||||
|
5 (4.81)& $^{10}$B & 2072 (3)& 27.5 (7)& 1.00 \\
|
||||||
|
& $^{11}$B & 2089 (3)& 23.5 (7)& 1.00 \\
|
||||||
|
6 (5.72)& $^{12}$C & 2028 (2)& 37.9 (5)& 1.00 \\
|
||||||
|
& $^{13}$C & 2037 (8)& 35.0 (20)& \\
|
||||||
|
7 (6.61)& $^{14}$N & 1919 (15)& 66 (4)& 1.00 \\
|
||||||
|
8 (7.49)& $^{16}$O & 1796 (3)& 102.5 (10)& 0.998 \\
|
||||||
|
& $^{18}$O & 1844 (5)& 88.0 (14)& \\
|
||||||
|
9 (8.32)& $^{19}$F & 1463 (5)& 229 (1)& 0.998 \\
|
||||||
|
13 (11.48)& $^{27}$Al& 864 (2)& 705 (3)& 0.993 \\
|
||||||
|
14 (12.22)& $^{28}$Si& 758 (2)& 868 (3)& 0.992 \\
|
||||||
|
20 (16.15)& Ca & 334 (2)& 2546 (20)& 0.985 \\
|
||||||
|
40 (25.61)& Zr & 110.4 (10)& 8630 (80)& 0.940 \\
|
||||||
|
82 (34.18)& Pb & 74.8 (4)& 12985 (70)& 0.844 \\
|
||||||
|
83 (34.00)& Bi & 73.4 (4)& 13240 (70)& 0.840 \\
|
||||||
|
90 (34.73)& Th & 77.3 (3)& 12560 (50)& 0.824 \\
|
||||||
|
92 (34.94)& U & 77.0 (4)& 12610 (70)& 0.820 \\
|
||||||
|
\bottomrule
|
||||||
|
\end{tabular}
|
||||||
|
\end{center}
|
||||||
|
\caption{Total nuclear capture rate for negative muon in several elements,
|
||||||
|
compiled by Measday~\cite{Measday.2001}}
|
||||||
|
\label{tab:total_capture_rate}
|
||||||
|
\end{table}
|
||||||
|
|
||||||
% subsection total_capture_rate (end)
|
% subsection total_capture_rate (end)
|
||||||
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
|
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
|
||||||
\subsection{Neutron emission}
|
\subsection{Neutron emission}
|
||||||
\label{sub:neutron_emission}
|
\label{sub:neutron_emission}
|
||||||
The average number of neutrons emitted per muon capture generally increases
|
The average number of neutrons emitted per muon capture generally increases
|
||||||
with $Z$, but there are large deviations from the trend due to particular
|
with $Z$, but there are large deviations from the trend due to particular
|
||||||
nuclear structure effects. The trend is shown in Table~\ref{tab:avg_neutron}
|
nuclear structure effects. The trend is shown in \cref{tab:avg_neutron}
|
||||||
and can be expressed by a simple empirical function
|
and can be expressed by a simple empirical function
|
||||||
$n_{avg} = (0.3 \pm 0.02)A^{1/3}$~\cite{Singer.1974}.
|
$n_{avg} = (0.3 \pm 0.02)A^{1/3}$~\cite{Singer.1974}.
|
||||||
\begin{table}[htb]
|
\begin{table}[htb]
|
||||||
@@ -347,18 +368,18 @@ $n_{avg} = (0.3 \pm 0.02)A^{1/3}$~\cite{Singer.1974}.
|
|||||||
The neutron emission can be explained by several mechanisms:
|
The neutron emission can be explained by several mechanisms:
|
||||||
\begin{enumerate}
|
\begin{enumerate}
|
||||||
\item Direct emission follows reaction~\eqref{eq:mucap_proton}: these neutrons
|
\item Direct emission follows reaction~\eqref{eq:mucap_proton}: these neutrons
|
||||||
have fairly high energy, from a few \si{\mega\electronvolt}~to as high as 40--50
|
have fairly high energy, from a few \si{\si{\MeV}}~to as high as 40--50
|
||||||
\si{\mega\electronvolt}.
|
\si{\si{\MeV}}.
|
||||||
\item Indirect emission through an intermediate compound nucleus: the energy
|
\item Indirect emission through an intermediate compound nucleus: the energy
|
||||||
transferred to the neutron in the process~\eqref{eq:mucap_proton} is 5.2
|
transferred to the neutron in the process~\eqref{eq:mucap_proton} is 5.2
|
||||||
\si{\mega\electronvolt} if the initial proton is at rest, in nuclear
|
\si{\si{\MeV}} if the initial proton is at rest, in nuclear
|
||||||
environment, protons have a finite momentum distribution, therefore the
|
environment, protons have a finite momentum distribution, therefore the
|
||||||
mean excitation energy of the daughter nucleus is around 15 to 20
|
mean excitation energy of the daughter nucleus is around 15 to 20
|
||||||
\si{\mega\electronvolt}~\cite{Mukhopadhyay.1977}. This is above the nucleon
|
\si{\si{\MeV}}~\cite{Mukhopadhyay.1977}. This is above the nucleon
|
||||||
emission threshold in all complex nuclei, thus the daughter nucleus can
|
emission threshold in all complex nuclei, thus the daughter nucleus can
|
||||||
de-excite by emitting one or more neutrons. In some actinide nuclei, that
|
de-excite by emitting one or more neutrons. In some actinide nuclei, that
|
||||||
excitation energy might trigger fission reactions. The energy of indirect
|
excitation energy might trigger fission reactions. The energy of indirect
|
||||||
neutrons are mainly in the lower range $E_n \le 10$ \si{\mega\electronvolt}
|
neutrons are mainly in the lower range $E_n \le 10$ \si{\si{\MeV}}
|
||||||
with characteristically exponential shape of evaporation process. On top of
|
with characteristically exponential shape of evaporation process. On top of
|
||||||
that are prominent lines might appear where giant resonances occur.
|
that are prominent lines might appear where giant resonances occur.
|
||||||
\end{enumerate}
|
\end{enumerate}
|
||||||
@@ -382,39 +403,43 @@ data. There are two reasons for that:
|
|||||||
neutron emission. The rate is about 15\% for light nuclei and
|
neutron emission. The rate is about 15\% for light nuclei and
|
||||||
reduces to a few percent for medium and heavy nuclei.
|
reduces to a few percent for medium and heavy nuclei.
|
||||||
\item The charged particles are short ranged: the emitted protons,
|
\item The charged particles are short ranged: the emitted protons,
|
||||||
deuterons and alphas are typically low energy (2--20~\mega\electronvolt).
|
deuterons and alphas are typically low energy ( \SIrange{2}{20}{\MeV}).
|
||||||
But a relatively thick target is normally needed in order to achieve
|
But a relatively thick target is normally needed in order to achieve
|
||||||
a reasonable muon stopping rate and charged particle statistics. Therefore,
|
a reasonable muon stopping rate and charged particle statistics. Therefore,
|
||||||
emulsion technique is particularly powerful.
|
emulsion technique is particularly powerful.
|
||||||
\end{enumerate}
|
\end{enumerate}
|
||||||
The first study was done by Morigana and Fry~\cite{MorinagaFry.1953} where
|
The first study was done by Morigana and Fry~\cite{MorinagaFry.1953} where
|
||||||
24,000 muon tracks were stopped in their nuclear emulsion which contains silver,
|
24,000 muon tracks were stopped in their nuclear emulsion which contains silver,
|
||||||
bromine, and other light elements, mainly nitrogen, carbon, hydrogen and
|
bromine AgBr, and other light elements, mainly nitrogen, carbon, hydrogen and
|
||||||
oxygen. The authors identified a capture on a light element as it would leave
|
oxygen. The authors identified a capture on a light element as it would leave
|
||||||
a recoil
|
a recoil
|
||||||
track of the nucleus. They found that for silver bromide AgBr, $(2.2 \pm
|
track of the nucleus. They found that for silver bromide, $(2.2 \pm
|
||||||
0.2)\%$ of the captures produced protons and $(0.5 \pm 0.1)\%$ produced alphas.
|
0.2)\%$ of the captures produced protons and $(0.5 \pm 0.1)\%$ produced alphas.
|
||||||
For light elements, the emission rate for proton and alpha are respectively
|
For light elements, the emission rate for proton and alpha are respectively
|
||||||
$(9.5 \pm 1.1)\%$ and $(3.4 \pm 0.7)\%$. Subsequently, Kotelchuk and
|
$(9.5 \pm 1.1)\%$ and $(3.4 \pm 0.7)\%$. Subsequently, Kotelchuk and
|
||||||
Tyler~\cite{KotelchuckTyler.1968} had a result which was about 3 times more
|
Tyler~\cite{KotelchuckTyler.1968} had a result which was about 3 times more
|
||||||
statistics and in fair agreement with Morigana and Fry
|
statistics and in fair agreement with Morigana and Fry
|
||||||
(Figure~\ref{fig:kotelchuk_proton_spectrum})
|
(\cref{fig:kotelchuk_proton_spectrum})
|
||||||
\begin{figure}[htb]
|
\begin{figure}[htb]
|
||||||
\centering
|
\centering
|
||||||
\includegraphics[width=0.65\textwidth]{figs/kotelchuk_proton_spectrum}
|
\includegraphics[width=0.65\textwidth]{figs/kotelchuk_proton_spectrum}
|
||||||
\caption{Early proton spectrum after muon capture in silver bromide AgBr
|
\caption{Proton spectrum after muon capture in silver bromide AgBr in
|
||||||
recorded using nuclear emulsion. Image is taken from
|
early experiments recorded using nuclear emulsion. The closed circles
|
||||||
Ref.~\cite{KotelchuckTyler.1968}}
|
are data points from Morigana and Fry~\cite{MorinagaFry.1953}, the
|
||||||
|
histogram is measurement result of Kotelchuk and
|
||||||
|
Tyler~\cite{KotelchuckTyler.1968}. Reprinted figure from
|
||||||
|
reference~\cite{KotelchuckTyler.1968}. Copyright 1968 by the American
|
||||||
|
Physical Society.}
|
||||||
\label{fig:kotelchuk_proton_spectrum}
|
\label{fig:kotelchuk_proton_spectrum}
|
||||||
\end{figure}
|
\end{figure}
|
||||||
|
|
||||||
Protons with higher energy are technically easier to measure, but because of
|
Protons with higher energy are technically easier to measure, but because of
|
||||||
the much lower rate, they can only be studied at meson facilities. Krane and
|
the much lower rate, they can only be studied at meson facilities. Krane and
|
||||||
colleagues~\cite{KraneSharma.etal.1979} measured proton emission from
|
colleagues~\cite{KraneSharma.etal.1979} measured proton emission from
|
||||||
aluminium, copper and lead in the energy range above 40 \mega\electronvolt~and
|
aluminium, copper and lead in the energy range above \SI{40}{\MeV} and
|
||||||
found a consistent exponential shape in all targets. The integrated yields
|
found a consistent exponential shape in all targets. The integrated yields
|
||||||
above 40 \mega\electronvolt~are in the \sn{}{-4}--\sn{}{-3} range (see
|
above \SI{40}{\MeV} are in the \sn{}{-4}--\sn{}{-3} range (see
|
||||||
Table~\ref{tab:krane_proton_rate}), a minor contribution to total proton
|
\cref{tab:krane_proton_rate}), a minor contribution to total proton
|
||||||
emission rate.
|
emission rate.
|
||||||
\begin{table}[htb]
|
\begin{table}[htb]
|
||||||
\begin{center}
|
\begin{center}
|
||||||
@@ -438,7 +463,7 @@ emission rate.
|
|||||||
\end{table}
|
\end{table}
|
||||||
|
|
||||||
Their result on aluminium, the only experimental data existing for this target,
|
Their result on aluminium, the only experimental data existing for this target,
|
||||||
is shown in Figure~\ref{fig:krane_proton_spec} in comparison with spectra from
|
is shown in \cref{fig:krane_proton_spec} in comparison with spectra from
|
||||||
neighbouring elements, namely silicon measured by Budyashov et
|
neighbouring elements, namely silicon measured by Budyashov et
|
||||||
al.~\cite{BudyashovZinov.etal.1971} and magnesium measured Balandin et
|
al.~\cite{BudyashovZinov.etal.1971} and magnesium measured Balandin et
|
||||||
al.~\cite{BalandinGrebenyuk.etal.1978}. The authors noted aluminium data and
|
al.~\cite{BalandinGrebenyuk.etal.1978}. The authors noted aluminium data and
|
||||||
@@ -454,24 +479,26 @@ might be at work in this mass range.
|
|||||||
target (closed circle) in the energy range above 40 MeV and an exponential
|
target (closed circle) in the energy range above 40 MeV and an exponential
|
||||||
fit. The open squares are silicon data from Budyashov et
|
fit. The open squares are silicon data from Budyashov et
|
||||||
al.~\cite{BudyashovZinov.etal.1971}, the open triangles are magnesium data
|
al.~\cite{BudyashovZinov.etal.1971}, the open triangles are magnesium data
|
||||||
from Balandin et al.~\cite{BalandinGrebenyuk.etal.1978}.}
|
from Balandin et al.~\cite{BalandinGrebenyuk.etal.1978}. Reprinted
|
||||||
|
figure from reference~\cite{KraneSharma.etal.1979}. Copyright 1979 by
|
||||||
|
the American Physical Society.}
|
||||||
\label{fig:krane_proton_spec}
|
\label{fig:krane_proton_spec}
|
||||||
\end{figure}
|
\end{figure}
|
||||||
|
|
||||||
The aforementioned difficulties in charged particle measurements could be
|
The aforementioned difficulties in charged particle measurements could be
|
||||||
solved using an active target, just like nuclear emulsion. Sobottka and
|
solved using an active target, just like nuclear emulsion. Sobottka and
|
||||||
Wills~\cite{SobottkaWills.1968} took this approach when using a Si(Li) detector
|
Wills~\cite{SobottkaWills.1968} took this approach when using a Si(Li) detector
|
||||||
to stop muons. They obtained a spectrum of charged particles up to 26
|
to stop muons. They obtained a spectrum of charged particles up to \SI{26}{\MeV}
|
||||||
\mega\electronvolt~in Figure~\ref{fig:sobottka_spec}. The peak below 1.4
|
in \cref{fig:sobottka_spec}. The peak below \SI{1.4}{\MeV}
|
||||||
\mega\electronvolt~is due to the recoiling $^{27}$Al. The higher energy events
|
is due to the recoiling $^{27}$Al. The higher energy events
|
||||||
including protons, deuterons and alphas constitute $(15\pm 2)\%$ of capture
|
including protons, deuterons and alphas constitute $(15\pm 2)\%$ of capture
|
||||||
events, which is consistent with a rate of $(12.9\pm1.4)\%$ from gelatine
|
events, which is consistent with a rate of $(12.9\pm1.4)\%$ from gelatine
|
||||||
observed by Morigana and Fry. This part has an exponential
|
observed by Morigana and Fry. This part has an exponential
|
||||||
decay shape with a decay constant of 4.6 \mega\electronvolt. Measday
|
decay shape with a decay constant of 4.6 \si{\MeV}. Measday
|
||||||
noted~\cite{Measday.2001} the fractions of events in
|
noted~\cite{Measday.2001} the fractions of events in
|
||||||
the 26--32 \mega\electronvolt~range being 0.3\%, and above 32
|
the 26--32 \si{\MeV}~range being 0.3\%, and above 32
|
||||||
\mega\electronvolt~range being 0.15\%. This figure is in agreement with the
|
\si{\MeV}~range being 0.15\%. This figure is in agreement with the
|
||||||
integrated yield above 40 \mega\electronvolt~from Krane et al.
|
integrated yield above 40 \si{\MeV}~from Krane et al.
|
||||||
|
|
||||||
In principle, the active target technique could be applied to other material
|
In principle, the active target technique could be applied to other material
|
||||||
such as germanium, sodium iodine, caesium iodine, and other scintillation
|
such as germanium, sodium iodine, caesium iodine, and other scintillation
|
||||||
@@ -480,13 +507,14 @@ identification like in nuclear emulsion, the best one can achieve after all
|
|||||||
corrections is a sum of all charged particles. It should be noted here
|
corrections is a sum of all charged particles. It should be noted here
|
||||||
deuterons can contribute significantly, Budyashov et
|
deuterons can contribute significantly, Budyashov et
|
||||||
al.~\cite{BudyashovZinov.etal.1971} found deuteron components to be
|
al.~\cite{BudyashovZinov.etal.1971} found deuteron components to be
|
||||||
$(34\pm2)\%$ of the charged particle yield above 18 \mega\electronvolt~in
|
$(34\pm2)\%$ of the charged particle yield above 18 \si{\MeV}~in
|
||||||
silicon, and $(17\pm4)\%$ in copper.
|
silicon, and $(17\pm4)\%$ in copper.
|
||||||
\begin{figure}[htb]
|
\begin{figure}[htb]
|
||||||
\centering
|
\centering
|
||||||
\includegraphics[width=0.75\textwidth]{figs/sobottka_spec}
|
\includegraphics[width=0.75\textwidth]{figs/sobottka_spec}
|
||||||
\caption{Charged particle spectrum from muon capture in a silicon detector,
|
\caption{Charged particle spectrum from muon capture in a silicon detector,
|
||||||
image taken from Sobottka and Wills~\cite{SobottkaWills.1968}.}
|
measured by Sobottka and Wills~\cite{SobottkaWills.1968}. The plot is
|
||||||
|
reproduced from the original figure in reference~\cite{SobottkaWills.1968}.}
|
||||||
\label{fig:sobottka_spec}
|
\label{fig:sobottka_spec}
|
||||||
\end{figure}
|
\end{figure}
|
||||||
|
|
||||||
@@ -513,42 +541,48 @@ active target measurement and found that the reaction
|
|||||||
$^{28}\textrm{Si}(\mu^-,\nu pn)^{26}\textrm{Mg}$ could occur at a similar rate
|
$^{28}\textrm{Si}(\mu^-,\nu pn)^{26}\textrm{Mg}$ could occur at a similar rate
|
||||||
to that of the $^{28}\textrm{Si}(\mu^-,\nu p)^{27}\textrm{Mg}$. That also
|
to that of the $^{28}\textrm{Si}(\mu^-,\nu p)^{27}\textrm{Mg}$. That also
|
||||||
indicates that the deuterons and alphas might constitute a fair amount in the
|
indicates that the deuterons and alphas might constitute a fair amount in the
|
||||||
spectrum in Figure~\ref{fig:sobottka_spec}.
|
spectrum in \cref{fig:sobottka_spec}.
|
||||||
|
|
||||||
Wyttenbach et al.~\cite{WyttenbachBaertschi.etal.1978} studied $(\mu^-,\nu p)$,
|
Wyttenbach et al.~\cite{WyttenbachBaertschi.etal.1978} studied $(\mu^-,\nu p)$,
|
||||||
$(\mu^-,\nu pn)$, $(\mu^-,\nu p2n)$, $(\mu^-,\nu p3n)$ and $(\mu^-,\nu\alpha)$
|
$(\mu^-,\nu pn)$, $(\mu^-,\nu p2n)$, $(\mu^-,\nu p3n)$ and $(\mu^-,\nu\alpha)$
|
||||||
in a wide range of 18 elements from sodium to bismuth.Their results plotted
|
in a wide range of 18 elements from sodium to bismuth.Their results plotted
|
||||||
against the Coulomb barrier for the outgoing protons are given in
|
against the Coulomb barrier for the outgoing protons are given in
|
||||||
Figure~\ref{fig:wyttenbach_rate_1p}, ~\ref{fig:wyttenbach_rate_23p}. The
|
\cref{fig:wyttenbach_rate_1p}.
|
||||||
classical Coulomb barrier $V$ they used are given by:
|
%and \cref{fig:wyttenbach_rate_23p}.
|
||||||
|
The classical Coulomb barrier $V$ they used are given by:
|
||||||
\begin{equation}
|
\begin{equation}
|
||||||
V = \frac{zZe^2}{r_0A^{\frac{1}{3}} + \rho},
|
V = \frac{zZe^2}{r_0A^{\frac{1}{3}} + \rho}\,,
|
||||||
\label{eqn:classical_coulomb_barrier}
|
\label{eqn:classical_coulomb_barrier}
|
||||||
\end{equation}
|
\end{equation}
|
||||||
where $z$ and $Z$ are the charges of the outgoing particle and of the residual
|
where $z$ and $Z$ are the charges of the outgoing particle and of the residual
|
||||||
nucleus, values $r_0 = 1.35 \textrm{ fm}$, and $\rho = 0 \textrm{ fm}$ for
|
nucleus respectively, $e^2 = 1.44 \si{\MeV}\cdot\textrm{fm}$, $r_0 = 1.35
|
||||||
protons were taken.
|
\textrm{ fm}$, and $\rho = 0 \textrm{ fm}$ for protons were taken.
|
||||||
\begin{figure}[htb]
|
\begin{figure}[htb]
|
||||||
\centering
|
\centering
|
||||||
\includegraphics[width=0.85\textwidth]{figs/wyttenbach_rate_1p}
|
\includegraphics[width=0.48\textwidth]{figs/wyttenbach_rate_1p}
|
||||||
\caption{Activation results from Wyttenbach et
|
\includegraphics[width=0.505\textwidth]{figs/wyttenbach_rate_23p}
|
||||||
al.~\cite{WyttenbachBaertschi.etal.1978} for the $(\mu^-,\nu p)$ and
|
\caption{Activation results from Wyttenbach and
|
||||||
$(\mu^-,\nu pn)$ reactions.}
|
colleagues~\cite{WyttenbachBaertschi.etal.1978} for the $(\mu^-,\nu p)$,
|
||||||
|
$(\mu^-,\nu pn)$, $(\mu^-,\nu p2n)$ and $(\mu^-,\nu p3n)$ reactions. The
|
||||||
|
cross section of each individual channels decreases exponentially as the
|
||||||
|
Coulomb barrier for proton emission increases.
|
||||||
|
Reprinted figure from reference~\cite{WyttenbachBaertschi.etal.1978} with
|
||||||
|
permission from Elsevier.}
|
||||||
\label{fig:wyttenbach_rate_1p}
|
\label{fig:wyttenbach_rate_1p}
|
||||||
\end{figure}
|
\end{figure}
|
||||||
\begin{figure}[htb]
|
%\begin{figure}[htb]
|
||||||
\centering
|
%\centering
|
||||||
\includegraphics[width=0.85\textwidth]{figs/wyttenbach_rate_23p}
|
%\includegraphics[width=0.85\textwidth]{figs/wyttenbach_rate_23p}
|
||||||
\caption{Activation results from Wyttenbach et
|
%\caption{Activation results from Wyttenbach et
|
||||||
al.~\cite{WyttenbachBaertschi.etal.1978} for the $(\mu^-,\nu p2n)$ and
|
%al.~\cite{WyttenbachBaertschi.etal.1978} for the $(\mu^-,\nu p2n)$ and
|
||||||
$(\mu^-,\nu p3n)$ reactions.}
|
%$(\mu^-,\nu p3n)$ reactions.}
|
||||||
\label{fig:wyttenbach_rate_23p}
|
%\label{fig:wyttenbach_rate_23p}
|
||||||
\end{figure}
|
%\end{figure}
|
||||||
|
|
||||||
Wyttenbach et al.\ saw that the cross section of each reaction decreases
|
Wyttenbach and colleagues saw that the cross section of each reaction decreases
|
||||||
exponentially with increasing Coulomb barrier. The decay constant for all
|
exponentially with increasing Coulomb barrier. The decay constant for all
|
||||||
$(\mu^-,\nu pxn)$ is about 1.5 per \mega\electronvolt~of Coulomb barrier. They
|
$(\mu^-,\nu pxn)$ is about 1.5 per \si{\MeV}~of Coulomb barrier. They
|
||||||
also commented a ratio for different de-excitation channels:
|
also observed a ratio for different de-excitation channels:
|
||||||
\begin{equation}
|
\begin{equation}
|
||||||
(\mu^-,\nu p):(\mu^-,\nu pn):(\mu^-,\nu p2n):(\mu^-,\nu p3n) = 1:6:4:4,
|
(\mu^-,\nu p):(\mu^-,\nu pn):(\mu^-,\nu p2n):(\mu^-,\nu p3n) = 1:6:4:4,
|
||||||
\label{eqn:wyttenbach_ratio}
|
\label{eqn:wyttenbach_ratio}
|
||||||
@@ -558,7 +592,7 @@ the results from Vil'gel'mova et al.~\cite{VilgelmovaEvseev.etal.1971} as being
|
|||||||
too high, but Measday~\cite{Measday.2001} noted it it is not
|
too high, but Measday~\cite{Measday.2001} noted it it is not
|
||||||
necessarily true since there has been suggestion from other experiments that
|
necessarily true since there has been suggestion from other experiments that
|
||||||
$(\mu^-, \nu p)$ reactions might become more important for light nuclei.
|
$(\mu^-, \nu p)$ reactions might become more important for light nuclei.
|
||||||
Measday also commented that the ratio~\eqref{eqn:wyttenbach_ratio} holds over
|
Measday noted that the ratio~\eqref{eqn:wyttenbach_ratio} holds over
|
||||||
a broad range of mass, but below $A=40$ the $(\mu^-,\nu p)$ reaction can vary
|
a broad range of mass, but below $A=40$ the $(\mu^-,\nu p)$ reaction can vary
|
||||||
significantly from nucleus to nucleus.
|
significantly from nucleus to nucleus.
|
||||||
% subsection experimental_status (end)
|
% subsection experimental_status (end)
|
||||||
@@ -572,33 +606,34 @@ nucleus is formed, and then it releases energy by statistical emission of
|
|||||||
various particles. Three models for momentum distribution of protons in the
|
various particles. Three models for momentum distribution of protons in the
|
||||||
nucleus were used: (I) the Chew-Goldberger distribution
|
nucleus were used: (I) the Chew-Goldberger distribution
|
||||||
$\rho(p) \sim A/(B^2 + p^2)^2$; (II) Fermi gas at zero temperature; and (III)
|
$\rho(p) \sim A/(B^2 + p^2)^2$; (II) Fermi gas at zero temperature; and (III)
|
||||||
Fermi gas at a finite temperature ($kT = 9$ \mega\electronvolt).
|
Fermi gas at a finite temperature ($kT = 9$ \si{\MeV}).
|
||||||
|
|
||||||
A very good agreement with the experimental result for the alpha emission was
|
A very good agreement with the experimental result for the alpha emission was
|
||||||
obtained with distribution (III), both in the absolute percentage and the energy
|
obtained with distribution (III).
|
||||||
distribution (curve (III) in the left hand side of
|
%, both in the absolute percentage and the energy
|
||||||
Figure~\ref{fig:ishii_cal_result}). However, the calculated emission of protons
|
%distribution (curve (III) in the left hand side of
|
||||||
at the same temperature falls short by about 10
|
%\cref{fig:ishii_cal_result}).
|
||||||
times compares to the data. The author also found that the distribution
|
However, the calculated emission rate of protons at the same temperature was 10
|
||||||
(I) is unlikely to be suitable for proton emission, and using that distribution
|
times smaller the experimental results from Morigana and Fry. The author
|
||||||
for alpha emission resulted in a rate 15 times larger than observed.
|
found the distribution (I) is unlikely to be suitable for proton emission,
|
||||||
|
and using that distribution
|
||||||
|
for alpha emission resulted in a rate 15 times larger than the observed rate.
|
||||||
|
|
||||||
\begin{figure}[htb]
|
%\begin{figure}[htb]
|
||||||
\centering
|
%\centering
|
||||||
\includegraphics[width=.49\textwidth]{figs/ishii_cal_alpha}
|
%\includegraphics[width=.49\textwidth]{figs/ishii_cal_alpha}
|
||||||
%\hspace{10mm}
|
%\includegraphics[width=.49\textwidth]{figs/ishii_cal_proton}
|
||||||
\includegraphics[width=.49\textwidth]{figs/ishii_cal_proton}
|
%\caption{Alpha spectrum (left) and proton spectrum (right) from Ishii's
|
||||||
\caption{Alpha spectrum (left) and proton spectrum (right) from Ishii's
|
%calculation~\cite{Ishii.1959} in comparison with experimental data from
|
||||||
calculation~\cite{Ishii.1959} in comparison with experimental data from
|
%Morigana and Fry. Image is taken from Ishii's paper.}
|
||||||
Morigana and Fry. Image is taken from Ishii's paper.}
|
%\label{fig:ishii_cal_result}
|
||||||
\label{fig:ishii_cal_result}
|
%\end{figure}
|
||||||
\end{figure}
|
|
||||||
Singer~\cite{Singer.1974} noted that by assuming a reduced effective mass for
|
Singer~\cite{Singer.1974} noted that by assuming a reduced effective mass for
|
||||||
the nucleon, the average excitation energy will increase, but the proton
|
the nucleon, the average excitation energy increases, but the proton
|
||||||
emission rate does not significantly improve and still could not explain the
|
emission rate is not significantly improved and still could not explain the
|
||||||
large discrepancy. He concluded that the evaporation mechanism can account
|
large discrepancy. He concluded that the evaporation mechanism can account
|
||||||
for only a small fraction of emitted protons. Moreover, the high energy protons
|
for only a small fraction of emitted protons. Moreover, the high energy protons
|
||||||
of 25--50 \mega\electronvolt~cannot be explained by the evaporation mechanism.
|
of 25--50 \si{\MeV}~cannot be explained by the evaporation mechanism.
|
||||||
He and Lifshitz~\cite{LifshitzSinger.1978, LifshitzSinger.1980} proposed two
|
He and Lifshitz~\cite{LifshitzSinger.1978, LifshitzSinger.1980} proposed two
|
||||||
major corrections to Ishii's model:
|
major corrections to Ishii's model:
|
||||||
\begin{enumerate}
|
\begin{enumerate}
|
||||||
@@ -611,23 +646,25 @@ major corrections to Ishii's model:
|
|||||||
is possibility for particles to escape from the nucleus.
|
is possibility for particles to escape from the nucleus.
|
||||||
\end{enumerate}
|
\end{enumerate}
|
||||||
With these improvements, the calculated proton spectrum agreed reasonably with
|
With these improvements, the calculated proton spectrum agreed reasonably with
|
||||||
data from Morigana and Fry in the energy range $E_p \le 30$ \mega\electronvolt.
|
data from Morigana and Fry in the energy range $E_p \le 30$ \si{\MeV}.
|
||||||
Lifshitz and Singer noted the pre-equilibrium emission is more important for
|
Lifshitz and Singer noted the pre-equilibrium emission is more important for
|
||||||
heavy nuclei. Its contribution in light nuclei is about a few percent,
|
heavy nuclei. Its contribution in light nuclei is about a few percent,
|
||||||
increasing to several tens of percent for $100<A<180$, then completely
|
increasing to several tens of percent for $100<A<180$, then completely
|
||||||
dominating in very heavy nuclei. This trend is also seen in other nuclear
|
dominating in very heavy nuclei. This trend is also seen in other nuclear
|
||||||
reactions at similar excitation energies. The pre-equilibrium emission also
|
reactions at similar excitation energies. The pre-equilibrium emission also
|
||||||
dominates the higher-energy part, although it falls short at energies higher
|
dominates the higher-energy part, although it falls short at energies higher
|
||||||
than 30 \mega\electronvolt. The comparison between the calculated proton
|
than 30 \si{\MeV}. The comparison between the calculated proton
|
||||||
spectrum and experimental data is shown in
|
spectrum and experimental data is shown in
|
||||||
Fig.~\ref{fig:lifshitzsinger_cal_proton}.
|
\cref{fig:lifshitzsinger_cal_proton}.
|
||||||
\begin{figure}[htb]
|
\begin{figure}[htb]
|
||||||
\centering
|
\centering
|
||||||
\includegraphics[width=0.85\textwidth]{figs/lifshitzsinger_cal_proton}
|
\includegraphics[width=0.85\textwidth]{figs/lifshitzsinger_cal_proton}
|
||||||
\caption{Proton energy spectrum from muon capture in AgBr, the data in
|
\caption{Proton energy spectrum from muon capture in AgBr, the data in
|
||||||
histogram is from Morigana and Fry, calculation by Lifshitz and
|
histogram is from Morigana and Fry, calculation by Lifshitz and
|
||||||
Singer~\cite{LifshitzSinger.1978} showed contributions from the
|
Singer~\cite{LifshitzSinger.1978} showed contributions from the
|
||||||
pre-equilibrium emission and the equilibrium emission.}
|
pre-equilibrium emission and the equilibrium emission. Reprinted figure
|
||||||
|
from reference~\cite{LifshitzSinger.1978}. Copyright 1978 by the American
|
||||||
|
Physical Society.}
|
||||||
\label{fig:lifshitzsinger_cal_proton}
|
\label{fig:lifshitzsinger_cal_proton}
|
||||||
\end{figure}
|
\end{figure}
|
||||||
|
|
||||||
@@ -641,36 +678,62 @@ proton emission rate $(\mu^-, \nu p)$ and the inclusive emission rate:
|
|||||||
The deuteron emission channels are included to comparisons with activation
|
The deuteron emission channels are included to comparisons with activation
|
||||||
data where there is no distinguish between $(\mu^-, \nu pn)$ and $(\mu^-,d)$,
|
data where there is no distinguish between $(\mu^-, \nu pn)$ and $(\mu^-,d)$,
|
||||||
\ldots Their calculated emission rates together with available experimental
|
\ldots Their calculated emission rates together with available experimental
|
||||||
data is reproduced in Table~\ref{tab:lifshitzsinger_cal_proton_rate}.
|
data is reproduced in \cref{tab:lifshitzsinger_cal_proton_rate} where
|
||||||
\begin{table}[htb]
|
a generally good agreement between calculation and experiment can be seen from.
|
||||||
\begin{center}
|
The rate of $(\mu^-,\nu p)$ reactions for $^{28}\textrm{Al}$ and
|
||||||
\begin{tabular}{c c c c c}
|
$^{39}\textrm{K}$ are found to be indeed
|
||||||
\toprule
|
|
||||||
Target nucleus & Calculation & Experiment & Estimate & Comments \\
|
|
||||||
%\textbf{Col1}\\
|
|
||||||
\midrule
|
|
||||||
$^{27}_{13}$Al & 40 & $>28 \pm 4$ & (70) & 7.5 for $T>40$ MeV \\
|
|
||||||
$^{28}_{14}$Si & 144 & $150\pm30$ & & 3.1 and 0.34 $d$ for $T>18$ MeV \\
|
|
||||||
$^{31}_{15}$P & 35 & $>61\pm6$ & (91) & \\
|
|
||||||
$^{46}_{22}$Ti & & & & \\
|
|
||||||
$^{51}_{23}$V & 25 & $>20\pm1.8$ & (32) & \\
|
|
||||||
%item1\\
|
|
||||||
\bottomrule
|
|
||||||
\end{tabular}
|
|
||||||
\end{center}
|
|
||||||
\caption{Calculated of the single proton emission rate and the inclusive
|
|
||||||
proton emission rate. The experimental data are mostly from Wyttenbach et
|
|
||||||
al.\cite{WyttenbachBaertschi.etal.1978}}
|
|
||||||
\label{tab:lifshitzsinger_cal_proton_rate}
|
|
||||||
\end{table}
|
|
||||||
A generally good agreement between calculation and experiment can be seen from
|
|
||||||
Table~\ref{tab:lifshitzsinger_cal_proton_rate}. The rate of $(\mu^-,\nu p)$
|
|
||||||
reactions for $^{28}\textrm{Al}$ and $^{39}\textrm{K}$ are found to be indeed
|
|
||||||
higher than average, though not as high as Vil'gel'mora et
|
higher than average, though not as high as Vil'gel'mora et
|
||||||
al.~\cite{VilgelmovaEvseev.etal.1971} observed.
|
al.~\cite{VilgelmovaEvseev.etal.1971} observed.
|
||||||
|
|
||||||
|
\begin{table}[htb]
|
||||||
|
\begin{center}
|
||||||
|
\begin{tabular}{l S S[separate-uncertainty=true]
|
||||||
|
S S[separate-uncertainty=true] c}
|
||||||
|
\toprule
|
||||||
|
{Capturing} & {$(\mu,\nu p)$} & {$(\mu,\nu p)$}&
|
||||||
|
{$\Sigma(\mu,\nu p(xn))$}&
|
||||||
|
{$\Sigma(\mu,\nu p(xn))$} & {Est.}\\
|
||||||
|
{nucleus} & {calculation} & {experiment} & {calculation} & {experiment}
|
||||||
|
&{}\\
|
||||||
|
%nucleus & calculation & experiment & calculation & experiment \\
|
||||||
|
%\textbf{Col1}\\
|
||||||
|
\midrule
|
||||||
|
$^{27}_{13}$Al & 9.7 & {(4.7)} & 40 & {$> 28 $} &(70)\\
|
||||||
|
$^{28}_{14}$Si & 32 & 53 \pm 10 & 144 & 150 \pm 30 & \\
|
||||||
|
$^{31}_{15}$P & 6.7 & {(6.3)} & 35 & {$> 61$}&(91) \\
|
||||||
|
$^{39}_{19}$K & 19 & 32 \pm 6 & 67 & {} \\
|
||||||
|
$^{41}_{19}$K & 5.1 & {(4.7)} & 30 & {$> 28$} &(70)\\
|
||||||
|
$^{51 }_{23}$V &3.7 &2.9 \pm 0.4 &25 &{$>20 \pm 1.8$}& (32)\\
|
||||||
|
$^{55 }_{25}$Mn &2.4 &2.8 \pm 0.4 &16 &{$>26 \pm 2.5$}& (35)\\
|
||||||
|
$^{59 }_{27}$Co &3.3 &1.9 \pm 0.2 &21 &{$>37 \pm 3.4$}& (50)\\
|
||||||
|
$^{60 }_{28}$Ni &8.9 &21.4 \pm 2.3 &49 &40 \pm 5&\\
|
||||||
|
$^{63 }_{29}$Cu &4.0 &2.9 \pm 0.6 &25 &{$>17 \pm 3 $}& (36)\\
|
||||||
|
$^{65 }_{29}$Cu &1.2 &{(2.3)} &11 &{$>35 \pm 4.5$}& (36)\\
|
||||||
|
$^{75 }_{33}$As &1.5 &1.4 \pm 0.2 &14 &{$>14 \pm 1.3$}& (19)\\
|
||||||
|
$^{79 }_{35}$Br &2.7 &{} &22 & &\\
|
||||||
|
$^{107}_{47}$Ag &2.3 &{} &18 & &\\
|
||||||
|
$^{115}_{49}$In &0.63 &{(0.77)} &7.2 &{$>11 \pm 1$} &(12)\\
|
||||||
|
$^{133}_{55}$Cs &0.75 &0.48 \pm 0.07 &8.7 &{$>4.9 \pm 0.5$} &(6.7)\\
|
||||||
|
$^{165}_{67}$Ho &0.26 &0.30 \pm 0.04 &4.1 &{$>3.4 \pm 0.3$} &(4.6)\\
|
||||||
|
$^{181}_{73}$Ta &0.15 &0.26 \pm 0.04 &2.8 &{$>0.7 \pm 0.1$} &(3.0)\\
|
||||||
|
$^{208}_{82}$Pb &0.14 &0.13 \pm 0.02 &1.1 &{$>3.0 \pm 0.8$} &(4.1)\\
|
||||||
|
\bottomrule
|
||||||
|
\end{tabular}
|
||||||
|
\end{center}
|
||||||
|
\caption{Probabilities in units of \num{E-3} per muon capture for the
|
||||||
|
reaction $^A_Z X (\mu,\nu p) ^{A-1}_{Z-2}Y$ and for inclusive proton
|
||||||
|
emission compiled by Measday~\cite{Measday.2001}. The calculated values
|
||||||
|
are from Lifshitz and Singer. The experimental data are mostly from
|
||||||
|
Wyttenbach and colleagues~\cite{WyttenbachBaertschi.etal.1978}. The
|
||||||
|
inclusive emission the experimental figures are lower limits because only
|
||||||
|
a few decay channels could be studied. The figures in crescent parentheses
|
||||||
|
are estimates for the total inclusive rate derived from the measured
|
||||||
|
exclusive channels by the use of ratio in \eqref{eqn:wyttenbach_ratio}.}
|
||||||
|
\label{tab:lifshitzsinger_cal_proton_rate}
|
||||||
|
\end{table}
|
||||||
|
|
||||||
For protons with higher energies in the range of
|
For protons with higher energies in the range of
|
||||||
40--90 \mega\electronvolt~observed in the emulsion data as well as in later
|
40--90 \si{\MeV}~observed in the emulsion data as well as in later
|
||||||
experiments~\cite{BudyashovZinov.etal.1971,BalandinGrebenyuk.etal.1978,
|
experiments~\cite{BudyashovZinov.etal.1971,BalandinGrebenyuk.etal.1978,
|
||||||
KraneSharma.etal.1979}, Lifshitz and Singer~\cite{LifshitzSinger.1988}
|
KraneSharma.etal.1979}, Lifshitz and Singer~\cite{LifshitzSinger.1988}
|
||||||
suggested another contribution from capturing on correlated two-nucleon
|
suggested another contribution from capturing on correlated two-nucleon
|
||||||
@@ -682,12 +745,12 @@ and it had been shown that the meson exchange current increases the total
|
|||||||
capture rate in deuterons by 6\%. The result of this model was a mix, it
|
capture rate in deuterons by 6\%. The result of this model was a mix, it
|
||||||
accounted well for Si, Mg and Pb data, but predicted rates about 4 times
|
accounted well for Si, Mg and Pb data, but predicted rates about 4 times
|
||||||
smaller in cases of Al and Cu, and about 10 times higher in case of AgBr
|
smaller in cases of Al and Cu, and about 10 times higher in case of AgBr
|
||||||
(Table~\ref{tab:lifshitzsinger_cal_proton_rate_1988}).
|
(\cref{tab:lifshitzsinger_cal_proton_rate_1988}).
|
||||||
\begin{table}[htb]
|
\begin{table}[!ht]
|
||||||
\begin{center}
|
\begin{center}
|
||||||
\begin{tabular}{l l c}
|
\begin{tabular}{l l c}
|
||||||
\toprule
|
\toprule
|
||||||
\textbf{Nucleus} & \textbf{Exp.$\times 10^3$} & \textbf{MEC cal.$\times
|
\textbf{Nucleus} & \textbf{Experiment$\times 10^3$} & \textbf{Calculation$\times
|
||||||
10^3$}\\
|
10^3$}\\
|
||||||
\midrule
|
\midrule
|
||||||
Al & $1.38 \pm 0.09$ & 0.3\\
|
Al & $1.38 \pm 0.09$ & 0.3\\
|
||||||
@@ -699,28 +762,30 @@ smaller in cases of Al and Cu, and about 10 times higher in case of AgBr
|
|||||||
\bottomrule
|
\bottomrule
|
||||||
\end{tabular}
|
\end{tabular}
|
||||||
\end{center}
|
\end{center}
|
||||||
\caption{Probability of proton emission with $E_p \ge 40$
|
\caption{Probability of proton emission with $E_p \ge \SI{40}{\MeV}$
|
||||||
\mega\electronvolt~as calculated by Lifshitz and
|
calculated by Lifshitz and
|
||||||
Singer~\cite{LifshitzSinger.1988} in comparison with available data.}
|
Singer~\cite{LifshitzSinger.1988} with the two-nucleon capture hypothesis
|
||||||
|
in comparison with available data.}
|
||||||
\label{tab:lifshitzsinger_cal_proton_rate_1988}
|
\label{tab:lifshitzsinger_cal_proton_rate_1988}
|
||||||
\end{table}
|
\end{table}
|
||||||
% subsection theoretical_models (end)
|
% subsection theoretical_models (end)
|
||||||
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
|
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
|
||||||
\subsection{Summary on proton emission from aluminium}
|
\subsection{Summary on proton emission from aluminium}
|
||||||
\label{sub:summary_on_proton_emission_from_aluminium}
|
\label{sub:summary_on_proton_emission_from_aluminium}
|
||||||
|
%%TODO equations, products as in Sobottkas'
|
||||||
There is no direct measurement of proton emission following
|
There is no direct measurement of proton emission following
|
||||||
muon capture in the relevant energy for the COMET Phase-I of 2.5--10
|
muon capture in the relevant energy for the COMET Phase-I of 2.5--10
|
||||||
\mega\electronvolt:
|
\si{\MeV}:
|
||||||
\begin{enumerate}
|
\begin{enumerate}
|
||||||
\item Spectrum wise, only one energy spectrum (Figure~\ref{fig:krane_proton_spec})
|
\item Spectrum wise, only one energy spectrum (\cref{fig:krane_proton_spec})
|
||||||
for energies above 40 \mega\electronvolt~is available from Krane et
|
for energies above 40 \si{\MeV}~is available from Krane et
|
||||||
al.~\cite{KraneSharma.etal.1979},
|
al.~\cite{KraneSharma.etal.1979},
|
||||||
where an exponential decay shape with a decay constant of
|
where an exponential decay shape with a decay constant of
|
||||||
$7.5 \pm 0.4$~\mega\electronvolt. At low energy range, the best one can get is
|
$7.5 \pm 0.4$~\si{\MeV}. At low energy range, the best one can get is
|
||||||
the charged particle spectrum, which includes protons, deuterons and alphas,
|
the charged particle spectrum, which includes protons, deuterons and alphas,
|
||||||
from the neighbouring element silicon (Figure~\ref{fig:sobottka_spec}).
|
from the neighbouring element silicon (\cref{fig:sobottka_spec}).
|
||||||
This charged particle spectrum peaks around 2.5 \mega\electronvolt~and
|
This charged particle spectrum peaks around 2.5 \si{\MeV}~and
|
||||||
reduces exponentially with a decay constant of 4.6 \mega\electronvolt.
|
reduces exponentially with a decay constant of 4.6 \si{\MeV}.
|
||||||
\item The activation data from Wyttenbach et
|
\item The activation data from Wyttenbach et
|
||||||
al.~\cite{WyttenbachBaertschi.etal.1978} only gives rate of
|
al.~\cite{WyttenbachBaertschi.etal.1978} only gives rate of
|
||||||
$^{27}\textrm{Al}(\mu^-,\nu pn)^{25}\textrm{Na}$ reaction, and set a lower
|
$^{27}\textrm{Al}(\mu^-,\nu pn)^{25}\textrm{Na}$ reaction, and set a lower
|
||||||
@@ -748,25 +813,25 @@ A spectrum shape at this energy range is not available.
|
|||||||
\label{sub:motivation_of_the_alcap_experiment}
|
\label{sub:motivation_of_the_alcap_experiment}
|
||||||
As mentioned, protons from muon capture on aluminium might cause a very high
|
As mentioned, protons from muon capture on aluminium might cause a very high
|
||||||
rate in the COMET Phase-I CDC. The detector is designed to accept particles
|
rate in the COMET Phase-I CDC. The detector is designed to accept particles
|
||||||
with momenta in the range of 75--120 \mega\electronvolt\per\cc.
|
with momenta in the range of \SIrange{75}{120}{\MeV\per\cc}.
|
||||||
Figure~\ref{fig:proton_impact_CDC} shows that protons with kinetic energies of
|
\cref{fig:proton_impact_CDC} shows that protons with kinetic energies larger
|
||||||
2.5--8 \mega\electronvolt~will hit the CDC. Such events are troublesome due to
|
than \SI{2.5}{\MeV} could hit the CDC. Such events are troublesome due to
|
||||||
their large energy deposition. Deuterons and alphas at that momentum range is
|
their large energy deposition. Deuterons and alphas at the same momentum are
|
||||||
not of concern because they have lower kinetic energy and higher stopping
|
not of concern because they have lower kinetic energy compared with protons and
|
||||||
power, thus are harder to escape the muon stopping target.
|
higher stopping power, thus are harder to escape the muon stopping target.
|
||||||
\begin{figure}[htb]
|
\begin{figure}[htb]
|
||||||
\centering
|
\centering
|
||||||
\includegraphics[width=0.85\textwidth]{figs/proton_impact_CDC}
|
\includegraphics[width=0.85\textwidth]{figs/alcap_proton_vs_acceptance}
|
||||||
\caption{Momentum-kinetic energy relation of protons, deuterons and alphas
|
\caption{Momentum - kinetic energy relation of protons, deuterons and alphas
|
||||||
below 10\mega\electronvolt. Shaded area is the acceptance of the COMET
|
at low energy region below 20\si{\MeV}. Charged particles in the shaded
|
||||||
Phase-I's CDC. Protons with energies in the range of 2.5--8
|
area could reach the COMET Phase-I's CDC, for protons that corresponds
|
||||||
\mega\electronvolt~are in the acceptance of the CDC. Deuterons and alphas at
|
kinetic energies higher than \SI{2.5}{\MeV}. Deuterons and alphas at low
|
||||||
low energies should be stopped inside the muon stopping target.}
|
energies should be stopped inside the muon stopping target.}
|
||||||
\label{fig:proton_impact_CDC}
|
\label{fig:proton_impact_CDC}
|
||||||
\end{figure}
|
\end{figure}
|
||||||
|
|
||||||
The COMET plans to introduce a thin, low-$Z$ proton absorber in between the
|
The COMET plans to introduce a thin, low-$Z$ proton absorber in between the
|
||||||
target and the CDC to produce proton hit rate. The absorber will be effective
|
target and the CDC to reduce proton hit rate. The absorber will be effective
|
||||||
in removing low energy protons. The high energy protons that are moderated by
|
in removing low energy protons. The high energy protons that are moderated by
|
||||||
the absorber will fall into the acceptance range of the CDC, but because of the
|
the absorber will fall into the acceptance range of the CDC, but because of the
|
||||||
exponential decay shape of the proton spectrum, the hit rate caused by these
|
exponential decay shape of the proton spectrum, the hit rate caused by these
|
||||||
@@ -774,12 +839,11 @@ protons should be affordable.
|
|||||||
|
|
||||||
The proton absorber solves the problem of hit rate, but it degrades the
|
The proton absorber solves the problem of hit rate, but it degrades the
|
||||||
reconstructed momentum resolution. Therefore its thickness and geometry should
|
reconstructed momentum resolution. Therefore its thickness and geometry should
|
||||||
be carefully designed. The limited information available makes it difficult to
|
be carefully optimised. The limited information available makes it difficult to
|
||||||
arrive at a conclusive detector design. The proton emission rate could be 4\%
|
arrive at a conclusive detector design. The proton emission rate could be 4\%
|
||||||
as calculated by Lifshitz and Singer~\cite{LifshitzSinger.1980}; or 7\% as
|
as calculated by Lifshitz and Singer~\cite{LifshitzSinger.1980}; or 7\% as
|
||||||
estimated from the $(\mu^-,\nu pn)$ activation data and the ratio
|
estimated from the $(\mu^-,\nu pn)$ activation data and the ratio in
|
||||||
\eqref{eqn:wyttenbach_ratio}~\cite{WyttenbachBaertschi.etal.1978}; or as high
|
\eqref{eqn:wyttenbach_ratio}; or as high as 15-20\% from silicon and neon.
|
||||||
as 15-20\% from silicon and neon.
|
|
||||||
|
|
||||||
For the moment, design decisions in the COMET Phase-I are made based on
|
For the moment, design decisions in the COMET Phase-I are made based on
|
||||||
conservative assumptions: emission rate of 15\% and an exponential decay shape
|
conservative assumptions: emission rate of 15\% and an exponential decay shape
|
||||||
@@ -787,58 +851,60 @@ are adopted follow the silicon data from Sobottka and Will
|
|||||||
~\cite{SobottkaWills.1968}. The spectrum shape is fitted with an empirical
|
~\cite{SobottkaWills.1968}. The spectrum shape is fitted with an empirical
|
||||||
function given by:
|
function given by:
|
||||||
\begin{equation}
|
\begin{equation}
|
||||||
p(T) = A\left(1-\frac{T_{th}}{T}\right)^\alpha e^{-(T/T_0)},
|
p(T) = A\left(1-\frac{T_{th}}{T}\right)^\alpha
|
||||||
|
\exp{\left(-\frac{T}{T_0}\right)},
|
||||||
\label{eqn:EH_pdf}
|
\label{eqn:EH_pdf}
|
||||||
\end{equation}
|
\end{equation}
|
||||||
where $T$ is the kinetic energy of the proton, and the fitted parameters are
|
where $T$ is the kinetic energy of the proton in \si{\MeV}, and the fitted
|
||||||
$A=0.105\textrm{ MeV}^{-1}$, $T_{th} = 1.4\textrm{ MeV}$, $\alpha = 1.328$ and
|
parameters are $A=0.105\textrm{ MeV}^{-1}$, $T_{th} = 1.4\textrm{ MeV}$,
|
||||||
$T_0 = 3.1\textrm{ MeV}$. The baseline
|
$\alpha = 1.328$ and $T_0 = 3.1\textrm{ MeV}$. The function rises from the
|
||||||
design of the absorber is 1.0 \milli\meter~thick
|
cut-off value of $T_{th}$, its rising edge is governed by the parameter
|
||||||
carbon-fibre-reinforced-polymer (CFRP) which contributes
|
$\alpha$. The exponential decay component dominates at higher energy.
|
||||||
195~\kilo\electronvolt\per\cc~to the momentum resolution. The absorber also
|
|
||||||
down shifts the conversion peak by 0.7 \mega\electronvolt. This is an issue as
|
The baseline design of the proton absorber for the COMET Phase-I based on
|
||||||
it pushes the signal closer to the DIO background region. For those reasons,
|
above assumptions is a 0.5-\si{\mm}-thick CFRP layer as has been described in
|
||||||
a measurement of the rate and spectrum of proton emission after muon capture is
|
\cref{ssub:hit_rate_on_the_cdc}. The hit rate estimation is
|
||||||
required in order to optimise the CDC design.
|
conservative and the contribution of the absorber to the momentum resolution
|
||||||
|
is not negligible, further optimisation is desirable. Therefore a measurement
|
||||||
|
of the rate and spectrum of proton emission after muon capture is required.
|
||||||
% subsection motivation_of_the_alcap_experiment (end)
|
% subsection motivation_of_the_alcap_experiment (end)
|
||||||
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
|
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
|
||||||
\subsection{Experimental method for proton measurement}
|
\subsection{Experimental method for proton measurement}
|
||||||
\label{sub:experimental_method}
|
\label{sub:experimental_method}
|
||||||
We planned to use a low energy, narrow momentum spread available at PSI to
|
We planned to use a low-energy, narrow-momentum-spread available at PSI to
|
||||||
fight the aforementioned difficulties in measuring protons. The beam momentum
|
fight the aforementioned difficulties in measuring protons. The beam momentum
|
||||||
is tunable from 28 to 45~\mega\electronvolt\ so that targets at different
|
is tunable from \SIrange{28}{45}{\MeV} so that targets at different
|
||||||
thickness from 25 to 100 \micro\meter\ can be studied. The $\pi$E1 beam line
|
thickness from \SIrange{25}{100}{\um} can be studied. The $\pi$E1 beam line
|
||||||
could provide about \sn{}{3} muons\per\second\ at 1\% momentum spread, and
|
could deliver \sn{}{3} muons/\si{\s} at 1\% momentum spread, and
|
||||||
\sn{}{4} muons\per\second\ at 3\% momentum spread. With this tunable beam, the
|
\sn{}{4} muons/\si{\s} at 3\% momentum spread. The muon stopping distribution
|
||||||
stopping distribution of the muons is well-defined.
|
of the muons could be well-tuned using this excellent beam.
|
||||||
|
|
||||||
The principle of the particle identification used in the AlCap experiment is
|
Emitting charged particles from nuclear muon capture will be identified by the
|
||||||
that for each species, the function describes the relationship between energy
|
specific energy loss.
|
||||||
loss per unit length (dE/dx) and the particle energy E is uniquely defined.
|
%The specific energy loss is calculated as energy loss
|
||||||
With a simple system of two detectors, dE/dx can be obtained by
|
%per unit path length \sdEdx at a certain energy $E$. The quantity is uniquely
|
||||||
measuring energy deposit $\Delta$E in one detector of known thickness
|
%defined for each particle species.
|
||||||
$\Delta$x, and E is the sum of energy deposit in both detector if the particle
|
Experimentally, the specific energy loss is measured in the AlCap using a pair
|
||||||
is fully stopped.
|
of silicon detectors: a \SI{65}{\um}-thick detector, and a \SI{1500}{\um}-thick
|
||||||
|
detector. Each detector is $5\times5$ \si{\cm^2} in area.
|
||||||
In the AlCap, we realise the idea with a pair of silicon detectors: one thin
|
The thinner one provides $\mathop{dE}$ information, while the sum energy
|
||||||
detector of 65~\micron\ serves as the $\Delta$E counter, and one thick detector
|
deposition in the two gives $E$, if the particle is fully stopped. The silicon
|
||||||
of 1500~\micron\ that can fully stop protons up to about 12~MeV. Since the
|
detectors pair could help distinguish protons from other charged particles from
|
||||||
$\Delta \textrm{d}=65$~\micron\ is known, the function relates dE/dx to
|
\SIrange{2.5}{12}{\MeV} as shown in \cref{fig:pid_sim}.
|
||||||
E reduces to a function between $\Delta$E and E. Figure~\ref{fig:pid_sim} shows
|
|
||||||
that the function of protons can be clearly distinguished from other charged
|
|
||||||
particles in the energy range of interest.
|
|
||||||
\begin{figure}[htbp]
|
\begin{figure}[htbp]
|
||||||
\centering
|
\centering
|
||||||
\includegraphics[width=0.75\textwidth]{figs/pid_sim}
|
\includegraphics[width=0.75\textwidth]{figs/pid_sim}
|
||||||
\caption{Simulation study of PID using a pair of silicon detectors}
|
\caption{Simulation study of PID using a pair of silicon detectors. The
|
||||||
|
detector resolutions follow the calibration results provided by the
|
||||||
|
manufacturer.}
|
||||||
\label{fig:pid_sim}
|
\label{fig:pid_sim}
|
||||||
\end{figure}
|
\end{figure}
|
||||||
|
|
||||||
The AlCap uses two pairs of detector with large area, placed symmetrically with
|
Two pairs of detectors, placed symmetrically with
|
||||||
respect to the target provide a mean to check for muon stopping distribution.
|
respect to the target, provide a mean to check for muon stopping distribution
|
||||||
The absolute number of stopped muons are inferred
|
inside the target. The absolute number of stopped muons is calculated
|
||||||
from the number of muonic X-rays recorded by a germanium detector. For
|
from the number of muonic X-rays recorded by a germanium detector. For
|
||||||
aluminium, the $(2p-1s)$ line is at 346 \kilo\electronvolt. The acceptances of
|
aluminium, the $(2p-1s)$ line is at \SI{346.828}{\keV}. The acceptances of
|
||||||
detectors will be assessed by detailed Monte Carlo study using Geant4.
|
detectors will be assessed by detailed Monte Carlo study using Geant4.
|
||||||
|
|
||||||
% subsection experimental_method (end)
|
% subsection experimental_method (end)
|
||||||
@@ -846,50 +912,63 @@ detectors will be assessed by detailed Monte Carlo study using Geant4.
|
|||||||
\subsection{Goals and plan of the experiment}
|
\subsection{Goals and plan of the experiment}
|
||||||
\label{sub:goals_of_the_experiment}
|
\label{sub:goals_of_the_experiment}
|
||||||
|
|
||||||
Our experimental program is organised in three distinct work packages (WP),
|
The goal of the experiment is measure protons following nuclear muon capture
|
||||||
|
on aluminium:
|
||||||
|
\begin{enumerate}
|
||||||
|
\item emission rate,
|
||||||
|
\item and spectrum shape in the lower energy region down to \SI{2.5}{\MeV},
|
||||||
|
\item with a precision of about 5\%.
|
||||||
|
\end{enumerate}
|
||||||
|
The measured proton spectrum and rate will be used to assess the hit rate on
|
||||||
|
the tracking drift chamber of the COMET Phase-I.
|
||||||
|
|
||||||
|
The measurement of protons itself is part of the AlCap, where
|
||||||
|
experimental program is organised in three distinct work packages (WP),
|
||||||
directed by different team leaders, given in parentheses.
|
directed by different team leaders, given in parentheses.
|
||||||
|
|
||||||
\begin{itemize}
|
\begin{itemize}
|
||||||
\item[WP1:] (Kammel (Seattle), Kuno(Osaka)) \textbf{Charged
|
\item[WP1:] (P. Kammel (University of Washington), Y. Kuno(Osaka University))
|
||||||
Particle Emission after Muon Capture.}\\ Protons emitted after nuclear muon
|
\textbf{Charged Particle Emission after Muon Capture.}\\ Protons emitted
|
||||||
capture in the stopping target dominate the single-hit rates in the tracking
|
after nuclear muon
|
||||||
chambers for both the Mu2e and COMET Phase-I experiments. We plan to measure
|
capture in the stopping target dominate the single-hit rates in the tracking
|
||||||
both the total rate and the energy spectrum to a precision of 5\% down to
|
chambers for both the Mu2e and COMET Phase-I experiments. We plan to measure
|
||||||
proton energies of 2.5 MeV.
|
both the total rate and the energy spectrum to a precision of 5\% down to
|
||||||
\item[WP2:] (Lynn(PNNL), Miller(BU))
|
proton energies of \SI{2.5}{\MeV}.
|
||||||
\textbf{Gamma and X-ray Emission after Muon Capture.}\\ A Ge detector will
|
\item[WP2:] (J. Miller(Boston University))
|
||||||
be used to measure X-rays from the muonic atomic cascade, in order to provide
|
\textbf{Gamma and X-ray Emission after Muon Capture.}\\ A germanium detector
|
||||||
the muon-capture normalization for WP1, and is essential for very thin
|
will be used to measure X-rays from the muonic atomic cascade, in order to
|
||||||
stopping targets. It is also the primary method proposed for calibrating the
|
provide
|
||||||
number of muon stops in the Mu2e and COMET experiments. Two additional
|
the muon-capture normalisation for WP1, and is essential for very thin
|
||||||
calibration techniques will also be explored; (1) detection of delayed gamma
|
stopping targets. It is also the primary method proposed for calibrating the
|
||||||
rays from nuclei activated during nuclear muon capture, and (2) measurement
|
number of muon stops in the Mu2e and COMET experiments. Two additional
|
||||||
of the rate of photons produced in radiative muon decay. The first of these
|
calibration techniques will also be explored; (1) detection of delayed gamma
|
||||||
would use a Ge detector and the second a NaI detector. The NaI
|
rays from nuclei activated during nuclear muon capture, and (2) measurement
|
||||||
calorimeter will measure the rate of high energy photons from radiative muon
|
of the rate of photons produced in radiative muon decay. The first of these
|
||||||
capture (RMC), electrons from muon decays in orbit (DIO), and photons from
|
would use a germanium detector and the second a sodium iodine detector.
|
||||||
radiative muon decay (RMD), as potential background sources for the
|
The sodium iodine
|
||||||
conversion measurement. As these rates are expected to be extremely low near
|
calorimeter will measure the rate of high energy photons from radiative muon
|
||||||
the conversion electron energy, only data at energies well below 100 MeV will
|
capture (RMC), electrons from muon decays in orbit (DIO), and photons from
|
||||||
be obtained.
|
radiative muon decay (RMD), as potential background sources for the
|
||||||
\item[WP3:] (Hungerford(UH), Winter(ANL)) \textbf{Neutron
|
conversion measurement. As these rates are expected to be extremely low near
|
||||||
Emission after Muon Capture.}\\ Neutron rates and spectra after capture in
|
the conversion electron energy, only data at energies well below 100 MeV will
|
||||||
Al and Ti are not well known. In particular, the low energy region below 10
|
be obtained.
|
||||||
MeV is important for determining backgrounds in the Mu2e/COMET detectors and
|
\item[WP3:] (E. Hungerford (University of Houston), P. Winter(Argonne
|
||||||
veto counters as well as evaluating the radiation damage to electronic
|
National Laboratory)) \textbf{Neutron
|
||||||
components. Carefully calibrated liquid scintillation detectors, employing
|
Emission after Muon Capture.}\\ Neutron rates and spectra after capture in
|
||||||
neutron-gamma discrimination and spectrum unfolding techniques, will measure
|
Al and Ti are not well known. In particular, the low energy region below 10
|
||||||
these spectra. The measurement will attempt to obtain spectra as low or lower
|
MeV is important for determining backgrounds in the Mu2e/COMET detectors and
|
||||||
than 1 MeV up to 10 MeV. \\
|
veto counters as well as evaluating the radiation damage to electronic
|
||||||
|
components. Carefully calibrated liquid scintillation detectors, employing
|
||||||
|
neutron-gamma discrimination and spectrum unfolding techniques, will measure
|
||||||
|
these spectra. The measurement will attempt to obtain spectra as low or lower
|
||||||
|
than 1 MeV up to 10 MeV. \\
|
||||||
\end{itemize}
|
\end{itemize}
|
||||||
|
|
||||||
WP1 is the most developed
|
WP1 was the most developed project in this program with most of the associated
|
||||||
project in this program. Most of the associated apparatus has been built and
|
apparatus had been built and optimised. Therefore the measurement of proton has
|
||||||
optimized. We are ready to start this experiment in 2013, while preparing and
|
been carried out in November and December 2013, while preparing and completing
|
||||||
completing test measurements and simulations to undertake WP2 and WP3.
|
test measurements and simulations to undertake WP2 and WP3.
|
||||||
|
|
||||||
The measurement of proton has been carried out in November and December 2013,
|
|
||||||
the details are described in following chapters.
|
|
||||||
% subsection goals_of_the_experiment (end)
|
% subsection goals_of_the_experiment (end)
|
||||||
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
|
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
|
||||||
% section the_alcap_experiment (end)
|
% section the_alcap_experiment (end)
|
||||||
|
|||||||
@@ -2,96 +2,105 @@
|
|||||||
\label{cha:the_alcap_run_2013}
|
\label{cha:the_alcap_run_2013}
|
||||||
\thispagestyle{empty}
|
\thispagestyle{empty}
|
||||||
The first run of the AlCap experiment was performed at the $\pi$E1 beam line
|
The first run of the AlCap experiment was performed at the $\pi$E1 beam line
|
||||||
area, PSI (Figure~\ref{fig:psi_exp_hall_all}) from November 26 to December 23,
|
area, PSI from November 26 to December 23, 2013. The goal of the run was to
|
||||||
2013. The goal of the run was to measure protons rate and spectrum following
|
measure protons rate and their spectrum following muon capture on aluminium.
|
||||||
muon capture on aluminium.
|
|
||||||
|
|
||||||
\begin{figure}[p]
|
|
||||||
\centering
|
|
||||||
\includegraphics[height=0.85\textheight]{figs/psi_exp_hall_all}
|
|
||||||
\caption{Layout of the PSI experimental hall, $\pi$E1 experimental area is
|
|
||||||
marked with the red circle. \\Image taken from
|
|
||||||
\url{http://www.psi.ch/num/FacilitiesEN/HallenplanPSI.png}}
|
|
||||||
\label{fig:psi_exp_hall_all}
|
|
||||||
\end{figure}
|
|
||||||
|
|
||||||
\section{Experimental set up}
|
\section{Experimental set up}
|
||||||
\label{sec:experimental_set_up}
|
\label{sec:experimental_set_up}
|
||||||
The low energy muons from the $\pi$E1 beam line were stopped in thin aluminium
|
The low energy muons from the $\pi$E1 beam line were stopped in thin aluminium
|
||||||
and silicon targets, and charged particles emitted were measured by two pairs
|
and silicon targets, and charged particles emitted were measured by two pairs
|
||||||
of silicon detectors inside of a vacuum vessel
|
of silicon detectors inside of a vacuum vessel
|
||||||
(Figure~\ref{fig:alcap_setup_detailed}). A stopped muon event is defined by
|
(\cref{fig:alcap_setup_detailed}). A stopped muon event is defined by
|
||||||
a group of upstream detectors and a muon veto plastic scintillator.
|
a group of upstream detectors and a muon veto plastic scintillator.
|
||||||
The number of stopped muons is monitored by a germanium detector placed outside
|
The number of stopped muons is monitored by a germanium detector placed outside
|
||||||
of the vacuum chamber. In addition, several plastic scintillators were used to
|
of the vacuum chamber. In addition, several plastic scintillators were used to
|
||||||
provide veto signals for the silicon and germanium detectors. Two liquid
|
provide veto signals for the silicon and germanium detectors. Two liquid
|
||||||
scintillators for neutron measurements were also tested in this run.
|
scintillators for neutron measurements were also tested in this run.
|
||||||
\begin{figure}[htbp]
|
\begin{figure}[btp]
|
||||||
\centering
|
\centering
|
||||||
\includegraphics[width=0.65\textwidth]{figs/alcap_setup_detailed}
|
\includegraphics[width=0.95\textwidth]{figs/alcap_setup_detailed}
|
||||||
\caption{AlCap detectors: two silicon packages inside the vacuum vessel,
|
\caption{AlCap detectors: two silicon packages inside the vacuum vessel,
|
||||||
muon beam detectors including plastic scintillators and a wire chamber,
|
muon beam detectors including plastic scintillators and a wire chamber,
|
||||||
germanium detector and veto plastic scintillators.}
|
germanium detector and veto plastic scintillators.}
|
||||||
\label{fig:alcap_setup_detailed}
|
\label{fig:alcap_setup_detailed}
|
||||||
\end{figure}
|
\end{figure}
|
||||||
|
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
|
||||||
\subsection{Muon beam and vacuum chamber}
|
\subsection{Muon beam and vacuum chamber}
|
||||||
Muons in the $\pi$E1 beam line are decay products of pions created
|
Muons in the $\pi$E1 beam line are decay products of pions created
|
||||||
as a 590~\mega\electronvolt\ proton beam hit a thick carbon target
|
as a \SI{590}{\mega\electronvolt} proton beam hits a thick carbon target. The
|
||||||
(E-target in Figure~\ref{fig:psi_exp_hall_all}). The beam line was designed to
|
beam line was designed to deliver muons with momenta ranging from
|
||||||
deliver muons with momenta ranging from 10 to 500~\mega\electronvolt\per\cc\
|
\SIrange{10}{500}{\mega\electronvolt\per\cc} and momentum spread from
|
||||||
and
|
\SIrange{0.26}{8.0}{\percent}~\cite{Foroughli.1997}. The beam parameters can
|
||||||
momentum spread from 0.26 to 8.0\%. These parameters can be selected by
|
be tuned by adjusting magnets and slits along the beam line.
|
||||||
changing various magnets and slits shown in
|
%These parameters can be
|
||||||
Figure~\ref{fig:psi_piE1_elements}~\cite{Foroughli.1997}.
|
%selected by changing various magnets and slits
|
||||||
|
%\cref{fig:psi_piE1_elements}.
|
||||||
|
|
||||||
\begin{figure}[htb]
|
%(E-target in \cref{fig:psi_exp_hall_all}).
|
||||||
\centering
|
%\begin{figure}[p]
|
||||||
\includegraphics[width=0.7\textwidth]{figs/psi_piE1_elements}
|
%\centering
|
||||||
\caption{The $\pi$E1 beam line}
|
%\includegraphics[height=0.85\textheight]{figs/psi_exp_hall_all}
|
||||||
\label{fig:psi_piE1_elements}
|
%\caption{Layout of the PSI experimental hall, $\pi$E1 experimental area is
|
||||||
\end{figure}
|
%marked with the red circle. \\Image taken from
|
||||||
|
%\url{http://www.psi.ch/num/FacilitiesEN/HallenplanPSI.png}}
|
||||||
|
%\label{fig:psi_exp_hall_all}
|
||||||
|
%\end{figure}
|
||||||
|
|
||||||
|
%\begin{figure}[btp]
|
||||||
|
%\centering
|
||||||
|
%\includegraphics[width=0.7\textwidth]{figs/psi_piE1_elements}
|
||||||
|
%\caption{The $\pi$E1 beam line}
|
||||||
|
%\label{fig:psi_piE1_elements}
|
||||||
|
%\end{figure}
|
||||||
|
|
||||||
One of the main requirements of the AlCap experiment was a low energy muon beam
|
One of the main requirements of the AlCap experiment was a low energy muon beam
|
||||||
with narrow momentum bite in order to achieve a high fraction of stopping muons
|
with narrow momentum bite in order to achieve a high fraction of stopping muons
|
||||||
in the very thin targets. In this Run 2013, muons from 28 to
|
in the very thin targets. In this Run 2013, muons from
|
||||||
45~\mega\electronvolt\per\cc\ and momentum spread of 1\% and 3\%were used.
|
\SIrange{28}{45}{\MeV\per\cc} and momentum spread of 1\% and
|
||||||
|
3\% were used.
|
||||||
|
|
||||||
For part of the experiment the target was replaced with one of the silicon
|
For part of the experiment the target was replaced with one of the silicon
|
||||||
detector packages allowed an accurate momentum and range calibration
|
detector packages allowed an accurate momentum and range calibration
|
||||||
%(via range-energy relations)
|
%(via range-energy relations)
|
||||||
of the beam at the target. Figure~\ref{fig:Rates} shows the measured muon rates
|
of the beam at the target. \Cref{fig:Rates} shows the measured muon rates
|
||||||
as a function of momentum for two different momentum bites.
|
as a function of momentum for two different momentum bites.
|
||||||
Figure~\ref{fig:Beam} shows an example of the resulting energy spectra.
|
\Cref{fig:Beam} shows an example of the resulting energy spectra recorded by
|
||||||
\begin{figure}[htbp]
|
our silicon detector.
|
||||||
|
\begin{figure}[btp]
|
||||||
\centering
|
\centering
|
||||||
\includegraphics[width=0.6\textwidth]{figs/Rates.png}
|
\includegraphics[width=0.65\textwidth]{figs/Rates.png}
|
||||||
\caption{Measured muon rate (kHz) at low momenta. Momentum bite of 3 and 1 \%
|
\caption{Measured muon rates at low momenta during the Run 2013. Beam rates
|
||||||
FWHM, respectively.}
|
at 1 \% FWHM momentum bite were about 3 times smaller than the rates at
|
||||||
|
3 \% FWHM.}
|
||||||
\label{fig:Rates}
|
\label{fig:Rates}
|
||||||
\end{figure}
|
\end{figure}
|
||||||
|
|
||||||
\begin{figure}[htbp]
|
\begin{figure}[btp]
|
||||||
\centering
|
\centering
|
||||||
\includegraphics[width=0.9\textwidth]{figs/beam.pdf}
|
\includegraphics[width=1.00\textwidth]{figs/beam.pdf}
|
||||||
\caption{Energy deposition at 36.4 MeV/c incident muon beam in an
|
\caption{Energy deposition at \SI{36.4}{/c} incident muon beam in an
|
||||||
1500-\micron-active
|
\SI{1500}{\micro\meter}-thick active target. The peak at low energy is due
|
||||||
target. The peak at low energy is due to beam electrons, the
|
to beam electrons, the peaks at higher energies are due to muons. Momentum
|
||||||
peaks at higher energies are due to muons. Momentum bite of 1 and 3\% FWHM
|
bite of 1 and 3\% FWHM on left and right hand side, respectively. The
|
||||||
on left and right hand side, respectively.} \label{fig:Beam}
|
electron peak are the same in both plots as beam electrons are minimum
|
||||||
|
ionisation particles and passed though the detector easily. The muon peak
|
||||||
|
at the 3 \% FWHM momentum bite is notably broader than that at 1 \% FWHM
|
||||||
|
setting.}
|
||||||
|
\label{fig:Beam}
|
||||||
\end{figure}
|
\end{figure}
|
||||||
|
|
||||||
The targets and charged particle detectors are installed inside the vacuum
|
The targets and charged particle detectors are installed inside the vacuum
|
||||||
chamber as shown in Figure~\ref{fig:alcap_setup_detailed}. The muon beam enters
|
chamber as shown in \cref{fig:alcap_setup_detailed}. The muon beam enters
|
||||||
from the right of the image and hits the target, which is placed at the
|
from the right of \cref{fig:alcap_setup_detailed} and hits the target, which is
|
||||||
centre of the vacuum chamber and orientated at 45 degrees to the beam axis.
|
placed at the centre of the vacuum chamber and orientated at 45 degrees to the
|
||||||
|
beam axis.
|
||||||
The side walls and bottom flange of the vessel provide several
|
The side walls and bottom flange of the vessel provide several
|
||||||
vacuum-feedthroughs for the high voltage and signal cables for the silicon and
|
vacuum-feedthroughs for the high voltage and signal cables for the silicon and
|
||||||
scintillator detectors inside the chamber.
|
scintillator detectors inside the chamber.
|
||||||
In addition, the chamber is equipped with several lead collimators
|
In addition, the chamber is equipped with several lead collimators
|
||||||
%so that muons that are not captured in the target would quickly decay.
|
%so that muons that are not captured in the target would quickly decay.
|
||||||
to quickly capture muons that do not stop in the actual target.
|
to quickly capture muons that do not stop in the actual target.
|
||||||
%\begin{figure}[htbp]
|
%\begin{figure}[btp]
|
||||||
%\centering
|
%\centering
|
||||||
%\includegraphics[width=0.55\textwidth]{figs/SetupOverview.jpg}
|
%\includegraphics[width=0.55\textwidth]{figs/SetupOverview.jpg}
|
||||||
%\caption{Vacuum chamber in beam line}
|
%\caption{Vacuum chamber in beam line}
|
||||||
@@ -102,22 +111,25 @@ to quickly capture muons that do not stop in the actual target.
|
|||||||
%a silicon detector in the low vacuum region of $10^{-3}$ mbar.
|
%a silicon detector in the low vacuum region of $10^{-3}$ mbar.
|
||||||
%An interlock mechanism was installed to prevent the bias of the
|
%An interlock mechanism was installed to prevent the bias of the
|
||||||
%silicon detectors from being applied before the safe vacuum level.
|
%silicon detectors from being applied before the safe vacuum level.
|
||||||
For a safe operation of the silicon detector, a vacuum of $<10^{-4}$\,mbar was
|
For a safe operation of the silicon detector, a vacuum of \SI{e-4}{\milli\bar}
|
||||||
necessary. With the help of the vacuum group of PSI, we could consistently
|
was necessary. With the help of the vacuum group of PSI, we could consistently
|
||||||
reach $10^{-4}$\,mbar within 45 minutes after closure of the chamber's top
|
reach the required vacuum level within 45 minutes after closure of the
|
||||||
flange.
|
chamber's top flange.
|
||||||
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
|
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
|
||||||
|
|
||||||
\subsection{Silicon detectors}
|
\subsection{Silicon detectors}
|
||||||
The main detectors for proton measurement in the Run 2013 were four large area
|
The main detectors for proton measurement in the Run 2013 were four large area
|
||||||
silicon detectors. The silicon detectors were grouped into two detector
|
silicon detectors. The silicon detectors were grouped into two detector
|
||||||
packages located symmetrically at 90 degrees of the nominal muon beam path, SiL
|
packages located symmetrically at 90 degrees of the nominal muon beam path, SiL
|
||||||
and SiR in Figure~\ref{fig:alcap_setup_detailed}. Each arm consists of: one
|
and SiR in \cref{fig:alcap_setup_detailed}. Each arm consists of: one
|
||||||
$\Delta$E counter, a 65-\micro\meter-thick silicon detector, divided into
|
$\Delta$E counter, a \SI{65}{\micro\meter}-thick silicon detector, divided into
|
||||||
4 quadrants; one E counter made from 1500-\micron-thick silicon; and one
|
4 quadrants; one E counter made from \SI{1500}{\micro\meter}-thick silicon; and
|
||||||
plastic scintillator to identify electrons or high energy protons that pass
|
one plastic scintillator to identify electrons or high energy protons that
|
||||||
through the silicon. The area of each of these silicon detectors and the
|
pass through the silicon. The area of each of these silicon detectors and the
|
||||||
scintillators is $50\times50 \textrm{mm}^2$.
|
scintillators is $50\times50 \textrm{mm}^2$. There is a dead layer of
|
||||||
|
\SI{0.5}{\micro\meter} on each side of the silicon detectors according to the
|
||||||
|
manufacturer Micron Semiconductor
|
||||||
|
\footnote{\url{http://www.micronsemiconductor.co.uk/}}.
|
||||||
|
|
||||||
The detectors were named according to their positions relative to the muon
|
The detectors were named according to their positions relative to the muon
|
||||||
view: the SiL package contains the thin
|
view: the SiL package contains the thin
|
||||||
@@ -129,11 +141,11 @@ SiR1-4.
|
|||||||
Bias for the four silicon detectors was supplied by an ORTEC 710 NIM module,
|
Bias for the four silicon detectors was supplied by an ORTEC 710 NIM module,
|
||||||
which has a vacuum interlock input to prevent biasing before the safe vacuum
|
which has a vacuum interlock input to prevent biasing before the safe vacuum
|
||||||
level has been reached. Typical voltage to fully depleted the detectors were
|
level has been reached. Typical voltage to fully depleted the detectors were
|
||||||
-300~\volt\ and -10~\volt\ for the thick and thin silicon detectors
|
\SI{-300}{\volt} and \SI{-10}{\volt} for the thick and thin silicon detectors
|
||||||
respectively. The leakage currents at the operating voltages are less than
|
respectively. The leakage currents at the operating voltages are less than
|
||||||
1.5~\micro\ampere\ for the thick detectors, and about 0.05~\micro\ampere\
|
\SI{1.5}{\micro\ampere} for the thick detectors, and about
|
||||||
for the thin ones (see Figure~\ref{fig:si_leakage}).
|
\SI{0.05}{\micro\ampere} for the thin ones (see \cref{fig:si_leakage}).
|
||||||
\begin{figure}[htb]
|
\begin{figure}[btp]
|
||||||
\centering
|
\centering
|
||||||
\includegraphics[width=0.85\textwidth]{figs/si_leakage}
|
\includegraphics[width=0.85\textwidth]{figs/si_leakage}
|
||||||
\caption{Leakage currents of the silicon detectors under bias.}
|
\caption{Leakage currents of the silicon detectors under bias.}
|
||||||
@@ -146,8 +158,8 @@ output
|
|||||||
pulse height on an oscilloscope. One would expect that the maximum pulse height
|
pulse height on an oscilloscope. One would expect that the maximum pulse height
|
||||||
increases as the bias is raised until the voltage of fully depleted. The effect
|
increases as the bias is raised until the voltage of fully depleted. The effect
|
||||||
can also be seen on the pulse height spectrum as in
|
can also be seen on the pulse height spectrum as in
|
||||||
Figure~\ref{fig:sir2_bias_alpha}.
|
\cref{fig:sir2_bias_alpha}.
|
||||||
\begin{figure}[htb]
|
\begin{figure}[btp]
|
||||||
\centering
|
\centering
|
||||||
\includegraphics[width=0.75\textwidth]{figs/sir2_bias_alpha}
|
\includegraphics[width=0.75\textwidth]{figs/sir2_bias_alpha}
|
||||||
\caption{$^{241}\textrm{Am}$ spectra in cases of fully depleted (top), and
|
\caption{$^{241}\textrm{Am}$ spectra in cases of fully depleted (top), and
|
||||||
@@ -195,15 +207,15 @@ Figure~\ref{fig:sir2_bias_alpha}.
|
|||||||
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
|
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
|
||||||
\subsection{Upstream counters}
|
\subsection{Upstream counters}
|
||||||
\label{sub:upstream_counters}
|
\label{sub:upstream_counters}
|
||||||
The upstream detector consists of three counters: a 500~$\mu$m thick
|
The upstream detector consists of three counters: a \SI{500}{\micro\meter}-thick
|
||||||
scintillator muon trigger counter ($\mu$SC); a muon anti-coincidence counter
|
scintillator muon trigger counter (\Pmu{}SC); a muon anti-coincidence counter
|
||||||
($\mu$SCA) surrounding the trigger counter with a hole
|
(\Pmu{}SCA) surrounding the trigger counter with a hole
|
||||||
of 35 \milli\meter\ in diameter to define the beam radius; and a multi-wire
|
of 35 \si{\milli\meter}\ in diameter to define the beam radius; and a multi-wire
|
||||||
proportional chamber ($\mu$PC) that uses 24 X wires and 24 Y wires at
|
proportional chamber (\Pmu{}PC) that uses 24 X wires and 24 Y wires at
|
||||||
2~\milli\meter~intervals.
|
2~\si{\milli\meter}~intervals.
|
||||||
|
|
||||||
The upstream detectors provide signal of an incoming muon as coincident hits on
|
The upstream detectors provide signal of an incoming muon as coincident hits on
|
||||||
the muon trigger and the wire chamber in anti-coincident with the muon
|
the muon trigger and the wire chamber in anti-coincidence with the muon
|
||||||
anti-coincidence counter.
|
anti-coincidence counter.
|
||||||
This set of detectors along with their read-out system
|
This set of detectors along with their read-out system
|
||||||
belong to the MuSun experiment, which operated at the same beam line just
|
belong to the MuSun experiment, which operated at the same beam line just
|
||||||
@@ -214,7 +226,7 @@ ready to be used in our run without any modification.
|
|||||||
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
|
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
|
||||||
|
|
||||||
\subsection{Germanium detector}
|
\subsection{Germanium detector}
|
||||||
%\begin{figure}[htbp]
|
%\begin{figure}[btp]
|
||||||
%\centering
|
%\centering
|
||||||
%\includegraphics[width=0.9\textwidth]{figs/neutron.png}
|
%\includegraphics[width=0.9\textwidth]{figs/neutron.png}
|
||||||
%\caption{Setup of two
|
%\caption{Setup of two
|
||||||
@@ -225,9 +237,9 @@ We used a germanium detector to normalise the number of stopped muons by
|
|||||||
measuring characteristics muon X-rays from the target material. The primary
|
measuring characteristics muon X-rays from the target material. The primary
|
||||||
X-rays of interest are the 346.828~keV line for aluminium targets, and the
|
X-rays of interest are the 346.828~keV line for aluminium targets, and the
|
||||||
400.177 line for silicon targets. The energies and intensities of the X-rays
|
400.177 line for silicon targets. The energies and intensities of the X-rays
|
||||||
listed in Table~\ref{tab:xray_ref} follow measurement results from
|
listed in \cref{tab:xray_ref} follow measurement results from
|
||||||
Measday and colleagues~\cite{MeasdayStocki.etal.2007}.
|
Measday and colleagues~\cite{MeasdayStocki.etal.2007}.
|
||||||
\begin{table}[htb]
|
\begin{table}[btp]
|
||||||
\begin{center}
|
\begin{center}
|
||||||
\begin{tabular}{c l l l l }
|
\begin{tabular}{c l l l l }
|
||||||
\toprule
|
\toprule
|
||||||
@@ -250,19 +262,25 @@ The germanium detector is
|
|||||||
a GMX20P4-70-RB-B-PL, n-type, coaxial high purity germanium detector produced
|
a GMX20P4-70-RB-B-PL, n-type, coaxial high purity germanium detector produced
|
||||||
by ORTEC. The detector was optimised for low energy gamma and X-rays
|
by ORTEC. The detector was optimised for low energy gamma and X-rays
|
||||||
measurement with an ultra-thin entrance window of 0.5-mm-thick beryllium and
|
measurement with an ultra-thin entrance window of 0.5-mm-thick beryllium and
|
||||||
a 0.3-\micron-thick ion implanted contact (Figure~\ref{fig:ge_det_dimensions}).
|
a 0.3-\si{\micro\meter}-thick ion implanted contact. The germanium crystal is
|
||||||
This detector is equipped with a transistor reset preamplifier which,
|
\SI{52.5}{\mm} in diameter, and \SI{55.3}{\mm} in length. The axial well has
|
||||||
according to the producer, enables it to work in an ultra-high rate environment
|
a diameter of \SI{9.9}{\mm} and \SI{47.8}{\mm} deep.
|
||||||
up to $10^6$ counts\per\second~ at 1~\mega\electronvolt.
|
%(\cref{fig:ge_det_dimensions}).
|
||||||
\begin{figure}[htb]
|
|
||||||
\centering
|
ORTEC quoted the energy resolution of the detector is \SI{1.90}{\keV} at the
|
||||||
\includegraphics[width=0.9\textwidth]{figs/ge_det_dimensions}
|
\SI{1.73}{\MeV} gamma line. The detector is equipped with a transistor reset
|
||||||
\caption{Dimensions of the germanium detector}
|
preamplifier which, according to the producer, enables it to work in an
|
||||||
\label{fig:ge_det_dimensions}
|
ultra-high rate environment
|
||||||
\end{figure}
|
up to $10^6$ counts\si{\per\second} at \SI{1}{\mega\electronvolt}.
|
||||||
|
%\begin{figure}[btp]
|
||||||
|
%\centering
|
||||||
|
%\includegraphics[width=0.9\textwidth]{figs/ge_det_dimensions}
|
||||||
|
%\caption{Dimensions of the germanium detector}
|
||||||
|
%\label{fig:ge_det_dimensions}
|
||||||
|
%\end{figure}
|
||||||
|
|
||||||
The detector was installed outside of the vacuum chamber at 32 cm from the
|
The detector was installed outside of the vacuum chamber at 32 cm from the
|
||||||
target, seeing the target through a 10-mm-thick aluminium window, behind
|
target, viewing the target through a 10-mm-thick aluminium window, behind
|
||||||
a plastic scintillator counter used to veto electrons. Liquid nitrogen
|
a plastic scintillator counter used to veto electrons. Liquid nitrogen
|
||||||
necessary for the operation of the detector had to be refilled every 8 hours.
|
necessary for the operation of the detector had to be refilled every 8 hours.
|
||||||
A timer was set up in the data acquisition system to remind this.
|
A timer was set up in the data acquisition system to remind this.
|
||||||
@@ -285,15 +303,16 @@ carried out.
|
|||||||
% subsection plastic_scintillators (end)
|
% subsection plastic_scintillators (end)
|
||||||
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
|
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
|
||||||
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
|
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
|
||||||
|
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
|
||||||
\section{Front-end electronics and data acquisition system}
|
\section{Front-end electronics and data acquisition system}
|
||||||
The front-end electronics of the AlCap experiment was simple since we employed
|
The front-end electronics of the AlCap experiment was simple since we employed
|
||||||
a trigger-less read out system with waveform digitisers and flash ADCs
|
a trigger-less read out system with waveform digitisers and flash ADCs
|
||||||
(FADCs). As shown in Figure~\ref{fig:alcapdaq_scheme}, all plastic
|
(FADCs). As shown in \cref{fig:alcapdaq_scheme}, all plastic
|
||||||
scintillators signals were amplified by PMTs, then fed into the digitisers. The
|
scintillators signals were amplified by PMTs, then fed into the digitisers. The
|
||||||
signals from silicon and germanium detectors were preamplified, and
|
signals from silicon and germanium detectors were preamplified, and
|
||||||
subsequently shaped by spectroscopy amplifiers and timing filter amplifiers
|
subsequently shaped by spectroscopy amplifiers and timing filter amplifiers
|
||||||
(TFAs) to provide energy and timing information.
|
(TFAs) to provide energy and timing information.
|
||||||
\begin{figure}[htbp]
|
\begin{figure}[btp]
|
||||||
\centering
|
\centering
|
||||||
\includegraphics[width=0.99\textwidth]{figs/alcapdaq_scheme}
|
\includegraphics[width=0.99\textwidth]{figs/alcapdaq_scheme}
|
||||||
\caption{Schematic diagram of the electronics and DAQ used in the Run 2013}
|
\caption{Schematic diagram of the electronics and DAQ used in the Run 2013}
|
||||||
@@ -304,34 +323,34 @@ The germanium detector has its own transistor reset preamplifier
|
|||||||
installed very close to the germanium crystal. Two ORTEC Model 142
|
installed very close to the germanium crystal. Two ORTEC Model 142
|
||||||
preamplifiers were used for the thick silicon detectors. The timing outputs of
|
preamplifiers were used for the thick silicon detectors. The timing outputs of
|
||||||
the preamplifiers were fed into three ORTEC Model 579 TFAs.
|
the preamplifiers were fed into three ORTEC Model 579 TFAs.
|
||||||
We used an ORTEC Model 673 to shape the germanium signal with 6~\micro\second
|
We used an ORTEC Model 673 to shape the germanium signal with 6~\si{\micro\second}
|
||||||
shaping time.
|
shaping time.
|
||||||
|
|
||||||
A more modern-style electronics was used for thin silicon detectors where the
|
A more modern-style electronics was used for thin silicon detectors where the
|
||||||
preamplifier, shaping and timing amplifiers were implemented on one compact
|
preamplifier, shaping and timing amplifiers were implemented on one compact
|
||||||
package, namely a Mesytec MSI-8 box. This box has 8 channels, each channel
|
package, namely a Mesytec MSI-8 box. This box has 8 channels, each channel
|
||||||
consists of one preamplifier board and one shaper-and-timing filter board which
|
consists of one preamplifier board and one shaper-and-timing filter board which
|
||||||
can be fine-tuned independently. The shaping time was set to 1~\micro\second\
|
can be fine-tuned independently. The shaping time was set to 1~\si{\micro\second}\
|
||||||
for all channels.
|
for all channels.
|
||||||
|
|
||||||
The detector system produced signals that differs significantly in time scale,
|
The detector system produced signals that differs significantly in time scale,
|
||||||
ranging from very fast (about 40~\nano\second\ from scintillators) to very slow
|
ranging from very fast (about 40~\si{\nano\second}\ from scintillators) to very slow
|
||||||
(several \micro\second\ from shaping outputs of semiconductor detectors). This
|
(several \si{\micro\second}\ from shaping outputs of semiconductor detectors). This
|
||||||
lead to the use of several sampling frequencies from 17~\mega\hertz\ to
|
lead to the use of several sampling frequencies from 17~\si{\mega\hertz}\ to
|
||||||
250~\mega\hertz, and three types of digitisers were employed:
|
250~\si{\mega\hertz}, and three types of digitisers were employed:
|
||||||
\begin{itemize}
|
\begin{itemize}
|
||||||
\item custom-built 12-bit 170-MHz FADCs which was designed for the
|
\item custom-built 12-bit 170-MHz FADCs which was designed for the
|
||||||
MuCap experiment. Each FADC board has dimensions the same as those of
|
MuCap experiment. Each FADC board has the same dimensions as those of
|
||||||
a single-width 6U VME module, but is hosted in a custom built crate due to
|
a single-width 6U VME module, but is hosted in a custom built crate due to
|
||||||
its different power supply mechanical structure. The FADC communicates with
|
its different power supply mechanical structure. The FADC communicates with
|
||||||
a host computer through a 100-Mb/s Ethernet interface using a simple
|
a host computer through a 100-Mb/s Ethernet interface using a simple
|
||||||
Ethernet-level protocol. The protocol only allows detecting
|
Ethernet-level protocol. The protocol only allows detecting
|
||||||
incomplete data transfers but no retransmitting is possible due to the
|
incomplete data transfers but no retransmitting is possible due to the
|
||||||
limited size of the module's output buffer. The FADCs accept clock signal
|
limited size of the module's output buffer. The FADCs accept clock signal
|
||||||
at the frequency of 50~\mega\hertz\ then multiply that internally up to
|
at the frequency of 50~\si{\mega\hertz}\ then multiply that internally up to
|
||||||
170~\mega\hertz. Each channel on one board can run at different sampling
|
170~\si{\mega\hertz}. Each channel on one board can run at different sampling
|
||||||
frequency not dependent on other channels. The FADC has 8 single-ended
|
frequency not dependent on other channels. The FADC has 8 single-ended
|
||||||
LEMO inputs with 1~\volt pp dynamic range.
|
LEMO inputs with 1~\si{\volt} pp dynamic range.
|
||||||
\item a 14-bit 100-MS/s CAEN VME FADC waveform digitiser model V1724. The
|
\item a 14-bit 100-MS/s CAEN VME FADC waveform digitiser model V1724. The
|
||||||
module houses 8 channels with 2.25~Vpp dynamic range on single-ended MCX
|
module houses 8 channels with 2.25~Vpp dynamic range on single-ended MCX
|
||||||
coaxial inputs. The digitiser features an optical link for transmission of
|
coaxial inputs. The digitiser features an optical link for transmission of
|
||||||
@@ -347,7 +366,7 @@ lead to the use of several sampling frequencies from 17~\mega\hertz\ to
|
|||||||
proprietary binary drivers and libraries.
|
proprietary binary drivers and libraries.
|
||||||
\end{itemize}
|
\end{itemize}
|
||||||
All digitisers were driven by external clocks which were derived from the same
|
All digitisers were driven by external clocks which were derived from the same
|
||||||
500-\mega\hertz\ master clock, a high precision RF signal generator Model SG382
|
500-\si{\mega\hertz}\ master clock, a high precision RF signal generator Model SG382
|
||||||
of Stanford Research System.
|
of Stanford Research System.
|
||||||
|
|
||||||
The silicon detectors were read out by FADC boards feature network-based data
|
The silicon detectors were read out by FADC boards feature network-based data
|
||||||
@@ -355,14 +374,14 @@ readout interface. To maximize the data throughput, each of the four FADC
|
|||||||
boards was read out through separate network adapter.
|
boards was read out through separate network adapter.
|
||||||
The CAEN digitisers were used to read out
|
The CAEN digitisers were used to read out
|
||||||
the germanium detector (timing and energy, slow signals) or scintillator
|
the germanium detector (timing and energy, slow signals) or scintillator
|
||||||
detectors (fast signals). For redundancy, all beam monitors ($\mu$SC, $\mu$SCA
|
detectors (fast signals). For redundancy, all beam monitors (\Pmu{}SC, \Pmu{}SCA
|
||||||
and $\mu$PC) were also read out by a CAEN time-to-digital converter (TDC)
|
and \Pmu{}PC) were also read out by a CAEN time-to-digital converter (TDC)
|
||||||
model V767 which was kindly provided by the MuSun experiment.
|
model V767 which was kindly provided by the MuSun experiment.
|
||||||
|
|
||||||
The Data Acquisition System (DAQ) of the AlCap experiment, so-called AlCapDAQ,
|
The Data Acquisition System (DAQ) of the AlCap experiment, so-called AlCapDAQ,
|
||||||
provided the readout of front-end electronics, event assembling, data logging,
|
provided the readout of front-end electronics, event assembling, data logging,
|
||||||
hardware monitoring and control, and the run database of the experiment
|
hardware monitoring and control, and the run database of the experiment
|
||||||
(Figure~\ref{fig:alcapdaq_pcs}). It was based on MIDAS framework~\footnote{
|
(\cref{fig:alcapdaq_pcs}). It was based on the MIDAS framework~\footnote{
|
||||||
MIDAS is a general purpose DAQ software system developed at PSI and TRIUMF:\\
|
MIDAS is a general purpose DAQ software system developed at PSI and TRIUMF:\\
|
||||||
\url{http://midas.triumf.ca}} and consisted of two circuits, {\em i})
|
\url{http://midas.triumf.ca}} and consisted of two circuits, {\em i})
|
||||||
a detector circuit for synchronous data readout from the front-end electronics
|
a detector circuit for synchronous data readout from the front-end electronics
|
||||||
@@ -375,7 +394,7 @@ running Linux operating system and connected into a private subnetwork.
|
|||||||
|
|
||||||
%\hl{TODO: storage and shift monitor}
|
%\hl{TODO: storage and shift monitor}
|
||||||
|
|
||||||
\begin{figure}[htb]
|
\begin{figure}[btp]
|
||||||
\centering
|
\centering
|
||||||
\includegraphics[width=0.95\textwidth]{figs/alcapdaq_pcs}
|
\includegraphics[width=0.95\textwidth]{figs/alcapdaq_pcs}
|
||||||
\caption{AlCapDAQ in the Run 2013. The {\ttfamily fe6} front-end is
|
\caption{AlCapDAQ in the Run 2013. The {\ttfamily fe6} front-end is
|
||||||
@@ -397,18 +416,329 @@ correlation between detectors would be established in the analysis stage.
|
|||||||
|
|
||||||
At the beginning of each block, the time counter in each digitiser is reset to
|
At the beginning of each block, the time counter in each digitiser is reset to
|
||||||
ensure time alignment across all modules. The period of 110~ms was chosen to be:
|
ensure time alignment across all modules. The period of 110~ms was chosen to be:
|
||||||
{\em i} long enough compares to the time scale of several \micro\second\ of the
|
{\em i}) long enough compared to the time scale of several \si{\micro\second}\
|
||||||
physics of interest, {\em ii} short enough so that there is no timer rollover
|
of the physics of interest, {\em ii}) short enough so that there is no timer
|
||||||
on any digitiser (a FADC runs at its maximum speed of 170~\mega\hertz\ could
|
rollover on any digitiser (a FADC runs at its maximum speed of
|
||||||
handle up to about 1.5 \second\ with its 28-bit time counter).
|
\SI{170}{\mega\hertz} could handle up to about \SI{1.5}{\second} with its
|
||||||
|
28-bit time counter).
|
||||||
|
|
||||||
To ease the task of handling data, the data collecting period was divided into
|
To ease the task of handling data, the data collecting period was divided into
|
||||||
short runs, each run stopped when the logger had recorded 2 GB of data.
|
short runs, each run stopped when the logger had recorded 2 GB of data.
|
||||||
The data size effectively made each run last for about 5 minutes. The DAQ
|
The data size effectively made each run last for about 5 minutes. The DAQ
|
||||||
automatically starts a new run with the same parameters after about 6 seconds.
|
automatically started a new run with the same parameters after about 6 seconds.
|
||||||
The short period of each run also allows the detection, and helps to reduce the
|
The short period of each run also allows the detection, and helps to reduce the
|
||||||
influence of effects such as electronics drifting, temperature fluctuation.
|
influence of effects such as electronics drifting, temperature fluctuation.
|
||||||
|
|
||||||
|
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
|
||||||
|
\section{Detector calibration}
|
||||||
|
\label{sec:detector_calibration}
|
||||||
|
The calibration was done mainly for the silicon and germanium detectors
|
||||||
|
because they would provide energy information. The plastic scintillators were
|
||||||
|
only checked by oscilloscopes to make sure that the minimum ionisation
|
||||||
|
particles (MIPs) could be observed. The upstream plastic scintillation
|
||||||
|
counters and wire chamber, as mentioned, were well-tuned by the MuSun group.
|
||||||
|
|
||||||
|
\subsection{Silicon detector}
|
||||||
|
\label{sub:silicon_detector}
|
||||||
|
The energy calibration for the silicon detectors were done routinely during the
|
||||||
|
run, by:
|
||||||
|
\begin{itemize}
|
||||||
|
\item a \SI{79.5}{\becquerel} $^{241}\textrm{Am}$ alpha source. The most
|
||||||
|
prominent alpha particles have energies of \SI{5.484}{\MeV} (85.2\%)
|
||||||
|
and \SI{5.442}{\MeV} (12.5\%). The alpha particles from the source
|
||||||
|
would lose about \SI{66}{\kilo\eV} in the \SI{0.5}{\um}-thick dead layer,
|
||||||
|
and the peak would appear at \SI{5418}{\kilo\eV} (\cref{fig:toyMC_alpha});
|
||||||
|
|
||||||
|
\item a tail pulse generator, A tail pulse with amplitude of
|
||||||
|
\SI{66}{\milli\volt}~was used to simulate the response of the silicon
|
||||||
|
detectors' preamplifiers to a particle with \SI{1}{\MeV} energy
|
||||||
|
deposition; and
|
||||||
|
|
||||||
|
\item during data taking period, electrons in the beam were were also used
|
||||||
|
for energy calibration of thick silicon detectors where energy deposition
|
||||||
|
is large enough. The muons at different momenta provided another mean of
|
||||||
|
calibration in the beam tuning period.
|
||||||
|
\end{itemize}
|
||||||
|
|
||||||
|
\begin{figure}[htb]
|
||||||
|
\centering
|
||||||
|
\includegraphics[width=0.6\textwidth]{figs/toyMC_alpha}
|
||||||
|
\caption{Energy loss of the alpha particles after a dead layer of
|
||||||
|
\SI{0.5}{\um}.}
|
||||||
|
\label{fig:toyMC_alpha}
|
||||||
|
\end{figure}
|
||||||
|
|
||||||
|
The conversion from ADC value to energy is done with a first-order polynomial:
|
||||||
|
\begin{equation}
|
||||||
|
\textrm{E [keV]} = \textrm{Slope} \times \textrm{ADC} + \textrm{Offset}.
|
||||||
|
\end{equation}
|
||||||
|
The calibration coefficients for the silicon channels are listed in
|
||||||
|
\cref{tab:cal_coeff}.
|
||||||
|
|
||||||
|
\begin{table}
|
||||||
|
\begin{center}
|
||||||
|
\pgfplotstabletypeset[
|
||||||
|
% separator
|
||||||
|
col sep=comma,
|
||||||
|
% columns displayed
|
||||||
|
display columns/0/.style={column name = \textbf{Detector}, string type,
|
||||||
|
column type=l},
|
||||||
|
display columns/1/.style={column name = \textbf{Slope}, column type=c,
|
||||||
|
dec sep align},
|
||||||
|
display columns/2/.style={column name = \textbf{Offset}, column type=r,
|
||||||
|
dec sep align},
|
||||||
|
% format the line breaks
|
||||||
|
every head row/.style={
|
||||||
|
before row={\toprule},
|
||||||
|
after row={\midrule},
|
||||||
|
%%TODO unit of coeffcients
|
||||||
|
%after row={ \arraybackslash
|
||||||
|
%{ }& { keV/channel } & { keV }\\
|
||||||
|
%\midrule},
|
||||||
|
%{}& {(keV/channel)} & {(keV)}\\ \midrule},
|
||||||
|
columns/Detector/.style={column type=c},
|
||||||
|
columns/Slope/.style={column type=c},
|
||||||
|
columns/Offset/.style={column type=c}
|
||||||
|
},
|
||||||
|
every last row/.style={after row=\bottomrule},
|
||||||
|
]{raw/si_cal_effs.csv}
|
||||||
|
\caption{Calibration coefficients of the silicon detector channels}
|
||||||
|
\label{tab:cal_coeff}
|
||||||
|
\end{center}
|
||||||
|
\end{table}
|
||||||
|
% subsection silicon_detector (end)
|
||||||
|
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
|
||||||
|
\subsection{Germanium detector}
|
||||||
|
\label{sub:germanium_detector}
|
||||||
|
The germanium detector was calibrated using a $^{152}\textrm{Eu}$
|
||||||
|
source
|
||||||
|
\footnote{Energies and intensities of gamma rays are taken from the
|
||||||
|
X-ray and Gamma-ray Decay Data Standards for Detector Calibration and Other
|
||||||
|
Applications, which is published by IAEA at \\
|
||||||
|
\url{https://www-nds.iaea.org/xgamma_standards/}},
|
||||||
|
the recorded pulse height spectrum is shown in \cref{fig:ge_eu152_spec}. The
|
||||||
|
source was placed at the target position so that the absolute efficiencies can
|
||||||
|
be calculated. The peak centroids and areas were obtained by fitting a Gaussian
|
||||||
|
peak on top of a first-order polynomial background. The only exception is the
|
||||||
|
\SI{1085.84}{\keV} line because of the interference of the \SI{1089.74}{\keV}
|
||||||
|
gamma, the two were fitted with two Gaussian peaks on top of a first-order
|
||||||
|
polynomial background.
|
||||||
|
|
||||||
|
The relation between pulse height in ADC value and energy is found to be:
|
||||||
|
\begin{equation}
|
||||||
|
\textrm{ E [keV]} = 0.1219 \times \textrm{ADC} + 1.1621
|
||||||
|
\end{equation}
|
||||||
|
The energy resolution (full width at half maximum - FWHM) was better than
|
||||||
|
2.6~\si{\keV}\ for all the $^{152}\textrm{Eu}$ peaks. It was
|
||||||
|
a little worse at 3.1~\si{\keV}~for the annihilation photons at
|
||||||
|
511.0~\si{\keV}.
|
||||||
|
|
||||||
|
\begin{figure}[htb]
|
||||||
|
\centering
|
||||||
|
\includegraphics[width=0.70\textwidth]{figs/ge_eu152_spec}
|
||||||
|
\caption{Energy spectrum of the $\rm^{152}\textrm{Eu}$ calibration source
|
||||||
|
recorded by the germanium detector. The most prominent peaks of
|
||||||
|
$^{152}\textrm{Eu}$ along with their energies are
|
||||||
|
annotated in red; the 1460.82 \si{\keV}~line is background from
|
||||||
|
$^{40}\textrm{K}$; and the annihilation 511.0~\si{\keV}~photons
|
||||||
|
come both from the source and the surrounding environment.}
|
||||||
|
\label{fig:ge_eu152_spec}
|
||||||
|
\end{figure}
|
||||||
|
|
||||||
|
\begin{figure}[htb]
|
||||||
|
\centering
|
||||||
|
\includegraphics[width=0.89\textwidth]{figs/ge_ecal_fwhm}
|
||||||
|
\caption{Germanium energy calibration and resolution.}
|
||||||
|
\label{fig:ge_fwhm}
|
||||||
|
\end{figure}
|
||||||
|
|
||||||
|
Following corrections for the peak areas are considered:
|
||||||
|
\begin{enumerate}
|
||||||
|
\item Correction for counting loss due to finite response time of the
|
||||||
|
detector system, where two gamma rays arrive at the detector within a time
|
||||||
|
interval short compared to that response time. This correction is
|
||||||
|
significant in our germanium system because of the current pulse
|
||||||
|
information extracting method does not count the second pulse (see
|
||||||
|
\cref{sub:offline_analyser}).
|
||||||
|
\item Correction of counting time loss in the reset periods of the transistor
|
||||||
|
reset preamplifier. A preamplifier of this type would reset itself after
|
||||||
|
accumulating a predetermined amount of charge. During a reset, the
|
||||||
|
preamplifier is insensitive so this can be counted as a dead time.
|
||||||
|
\item True coincidence summing correction: two cascade gamma rays hit the
|
||||||
|
detector at the same time would cause loss of counts under the two
|
||||||
|
respective peaks and gain under the sum energy peak.
|
||||||
|
\item Correction for self-absorption of a gamma ray by the source itself.
|
||||||
|
\end{enumerate}
|
||||||
|
|
||||||
|
The corrections for the first two mechanisms can be estimated by examining
|
||||||
|
pulse length and intervals between two consecutive pulses in the germanium
|
||||||
|
detector (\cref{fig:ge_cal_rate_pulselength}). The average pulse
|
||||||
|
length is \SI{45.7}{\um}, the average count rate obtained from the decay rate
|
||||||
|
of the interval spectrum is \SI{240}{\per\s}.
|
||||||
|
|
||||||
|
The correction factor for the finite response time of the detector system is
|
||||||
|
calculated as:
|
||||||
|
\begin{align}
|
||||||
|
k_{\textrm{finite response time}} &= e^{2\times \textrm{(pulse length)}
|
||||||
|
\times \textrm{(count rate)}}\\
|
||||||
|
&= e^{2\times 47.5\times10^{-6} \times 241} \nonumber\\
|
||||||
|
&= 1.02 \label{eqn:finite_time_response}
|
||||||
|
\end{align}
|
||||||
|
|
||||||
|
The resets of the preamplifier show up as a peak around \SI{2}{\ms},
|
||||||
|
consistent with specification of the manufacturer. Fitting the peak on top of
|
||||||
|
an exponential background gives the actual reset pulse length of
|
||||||
|
\SI{1947.34}{\us} and the number of resets during the calibration runs is
|
||||||
|
2335.0. The total time loss for resetting is hence:
|
||||||
|
$1947.34\times 10^{-6} \times 2335.0 = 4.55$ \si{\s}. That is a 0.14\% loss
|
||||||
|
for a measuring time of \SI{3245.5}{\s}. This percentage loss is insignificant
|
||||||
|
compared with the loss in \eqref{eqn:finite_time_response} and the statistical
|
||||||
|
uncertainty of peak areas.
|
||||||
|
|
||||||
|
\begin{figure}[htb]
|
||||||
|
\centering
|
||||||
|
\includegraphics[width=0.95\textwidth]{figs/ge_cal_rate_pulselength}
|
||||||
|
\caption{Germanium detector pulse length (left) and intervals between pulses
|
||||||
|
on that detector (right). The peak around \SI{2}{\ms} corresponds to the
|
||||||
|
resets of the preamplifier. The peak at \SI{250}{\us} is due to triggering
|
||||||
|
by the timing channel which is on the same digitiser.}
|
||||||
|
\label{fig:ge_cal_rate_pulselength}
|
||||||
|
\end{figure}
|
||||||
|
|
||||||
|
The true coincidence summing probability is estimated to be very small, about
|
||||||
|
\num{5.4d-6}, thanks to the far geometry of the calibration. The absorption in
|
||||||
|
the source cover made of \SI{22}{\mg\per\cm^2} polyethylene is less than
|
||||||
|
\num{4d-4} for a \SI{100}{\keV} photon. Therefore these two corrections are
|
||||||
|
omitted.
|
||||||
|
|
||||||
|
The absolute efficiencies of the reference gamma rays show agreement with those
|
||||||
|
obtained from a Monte Carlo (MC) study where a point source made of $^{152}$Eu
|
||||||
|
is placed at the target position (see \cref{fig:ge_eff_cal}). A comparison
|
||||||
|
between efficiencies in case of the point-like source and a finite-size
|
||||||
|
source is also done by MC simulation. The differences between the two sources
|
||||||
|
are generally smaller than 3\%, which are comparable with the uncertainties of
|
||||||
|
the efficiency calibration. That means the point-like efficiencies can be used
|
||||||
|
for a finite-sized source without correction.
|
||||||
|
%As shown in \cref{fig:ge_eff_cal}, the
|
||||||
|
%differences are in line with the uncertainties of the measured efficiencies.
|
||||||
|
%The dimensions of the latter are set to
|
||||||
|
%resemble the distribution of muons inside the target: Gaussian spreading
|
||||||
|
%\SI{11}{\mm} vertically, \SI{13}{\mm} horizontally, and \SI{127}{\um} in
|
||||||
|
\begin{figure}[htb]
|
||||||
|
\centering
|
||||||
|
\includegraphics[width=0.40\textwidth]{figs/ge_eff_cal}
|
||||||
|
\includegraphics[width=0.40\textwidth]{figs/ge_eff_mc_finitesize_vs_pointlike_root}
|
||||||
|
\caption{Absolute efficiency of the germanium detector (right) and
|
||||||
|
MC comparison of efficiencies in case of point-like and finite-sized
|
||||||
|
sources (left). The efficiencies curve is fitted on
|
||||||
|
7 measured energy points from \SIrange{244}{1408}{\keV}, the shaded area is
|
||||||
|
95\% confidence interval of the fit. The ratios on the left plot are
|
||||||
|
normalised to the efficiencies of the point-like case at each energy point.}
|
||||||
|
%because it is known that the linearity between
|
||||||
|
%$ln(\textrm{E})$ and $ln(\textrm{eff})$ holds better.
|
||||||
|
\label{fig:ge_eff_cal}
|
||||||
|
\end{figure}
|
||||||
|
The absolute efficiencies of the referenced points, and calculated efficiencies
|
||||||
|
at X-rays of interest are listed in \cref{tab:xray_eff}.
|
||||||
|
\begin{table}[htb]
|
||||||
|
\begin{center}
|
||||||
|
\pgfplotstabletypeset[
|
||||||
|
% separator
|
||||||
|
col sep=comma,
|
||||||
|
% columns displayed
|
||||||
|
% column type={S} means leave formatting to siunitx
|
||||||
|
display columns/0/.style={column name = \textbf{Photons (\si{\keV})},
|
||||||
|
string type,
|
||||||
|
column type={S[table-format=4.3, table-alignment=center]}},
|
||||||
|
display columns/1/.style={column name = \textbf{Efficiency},
|
||||||
|
string type,
|
||||||
|
column type={S[parse-numbers = true,
|
||||||
|
round-precision=3,
|
||||||
|
round-mode=figures,
|
||||||
|
fixed-exponent=-4,
|
||||||
|
scientific-notation=fixed,
|
||||||
|
table-format=1.2e-1,
|
||||||
|
%table-omit-exponent,
|
||||||
|
]}},
|
||||||
|
display columns/2/.style={column name = \textbf{Uncertainty},
|
||||||
|
string type,
|
||||||
|
column type={S[parse-numbers = true,
|
||||||
|
round-precision=3,
|
||||||
|
round-mode=figures,
|
||||||
|
fixed-exponent=-5,
|
||||||
|
scientific-notation=fixed,
|
||||||
|
table-format=1.3e-1,
|
||||||
|
%table-omit-exponent,
|
||||||
|
]}},
|
||||||
|
% format the line breaks
|
||||||
|
every head row/.style={
|
||||||
|
before row={\toprule},
|
||||||
|
after row={
|
||||||
|
%\textbf{\si{\keV}} & \textbf{\num{E-4}} & \textbf{\num{E-4}}\\
|
||||||
|
\midrule},
|
||||||
|
columns/0/.style={column type=r},
|
||||||
|
columns/1/.style={column type=c},
|
||||||
|
columns/2/.style={column type=c}
|
||||||
|
},
|
||||||
|
every last row/.style={after row=\bottomrule},
|
||||||
|
every nth row={8}{before row={\midrule}},
|
||||||
|
]{raw/ge_eff.csv}
|
||||||
|
\end{center}
|
||||||
|
\caption{Absolute efficiencies of the germanium detector in case of
|
||||||
|
a point-like source placed at the centre of the target (upper half), and
|
||||||
|
the calculated efficiencies for the X-rays of interest (lower half).}
|
||||||
|
\label{tab:xray_eff}
|
||||||
|
\end{table}
|
||||||
|
|
||||||
|
% subsection germanium_detector (end)
|
||||||
|
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
|
||||||
|
%\subsection{Beam tuning and muon momentum scanning}
|
||||||
|
%\label{sub:muon_momentum_scanning}
|
||||||
|
%Before taking any data, we carried out the muon momentum scanning to understand
|
||||||
|
%the muon beam, as well as calibrate the detector system. The nominal muon
|
||||||
|
%momentum used in the Run 2013 had been tuned to 28~MeV\cc\ before the run. By
|
||||||
|
%changing simultaneously the strength of the key magnet elements in the $\pi$E1
|
||||||
|
%beam line with the same factor, the muon beam momentum would be scaled with the
|
||||||
|
%same factor.
|
||||||
|
|
||||||
|
%The first study was on the range of muons in an active silicon target. The SiL2
|
||||||
|
%detector was placed perpendicular to the nominal beam path, after an oval
|
||||||
|
%collimator. The beam momentum scaling factor was scanned from 1.10 to 1.60,
|
||||||
|
%muon momenta and energies in the measured points are listed in
|
||||||
|
%\cref{tab:mu_scales}.
|
||||||
|
%\begin{table}[htbp]
|
||||||
|
%\begin{center}
|
||||||
|
%\begin{tabular}{c c c c}
|
||||||
|
%\toprule
|
||||||
|
%\textbf{Scaling} & \textbf{Momentum} & \textbf{Kinetic energy}
|
||||||
|
%& \textbf{Momentum spread}\\
|
||||||
|
%\textbf{factor} & \textbf{(MeV\per\cc)} & \textbf{(MeV)}
|
||||||
|
%& \textbf{(MeV\per\cc, 3\% FWHM)}\\
|
||||||
|
%\midrule
|
||||||
|
%1.03 & 28.84 & 3.87& 0.87\\
|
||||||
|
%1.05 & 29.40 & 4.01& 0.88\\
|
||||||
|
%1.06 & 29.68 & 4.09& 0.89\\
|
||||||
|
%1.07 & 29.96 & 4.17& 0.90\\
|
||||||
|
%1.10 & 30.80 & 4.40& 0.92\\
|
||||||
|
%1.15 & 32.20 & 4.80& 0.97\\
|
||||||
|
%1.20 & 33.60 & 5.21& 1.01\\
|
||||||
|
%1.30 & 36.40 & 6.09& 1.09\\
|
||||||
|
%1.40 & 39.20 & 7.04& 1.18\\
|
||||||
|
%1.43 & 40.04 & 7.33& 1.20\\
|
||||||
|
%1.45 & 40.60 & 7.53& 1.22\\
|
||||||
|
%1.47 & 41.16 & 7.73& 1.23\\
|
||||||
|
%1.50 & 42.00 & 8.04& 1.26\\
|
||||||
|
%\bottomrule
|
||||||
|
%\end{tabular}
|
||||||
|
%\end{center}
|
||||||
|
%\caption{Muon beam scaling factors, energies and momenta.}
|
||||||
|
%\label{tab:mu_scales}
|
||||||
|
%\end{table}
|
||||||
|
|
||||||
|
% subsection muon_momentum_scanning (end)
|
||||||
|
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
|
||||||
|
% section detector_calibration (end)
|
||||||
|
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
|
||||||
\section{Data sets and statistics}
|
\section{Data sets and statistics}
|
||||||
\label{sec:data_sets}
|
\label{sec:data_sets}
|
||||||
|
|
||||||
@@ -431,14 +761,14 @@ different targets were carried out for silicon targets:
|
|||||||
|
|
||||||
As the emitted protons deposit a significant amount of energy in the target
|
As the emitted protons deposit a significant amount of energy in the target
|
||||||
material, thin targets and thus excellent momentum resolution of the low energy
|
material, thin targets and thus excellent momentum resolution of the low energy
|
||||||
muon beam are critical. Aluminium targets of 50-\micro\meter\ and
|
muon beam are critical, aluminium targets of 50-\si{\micro\meter}\ and
|
||||||
100~\micron\ thick were used. Although a beam with low momentum spread of
|
100-\si{\micro\meter}\ thick were used. Although a beam with low momentum
|
||||||
1\% is preferable, it was used for only a small portion of the run due to the
|
spread of 1\% is preferable, it was used for only a small portion of the run
|
||||||
low beam rate (see Figure~\ref{fig:Rates}). The beam momentum for each target
|
due to the low beam rate (see \cref{fig:Rates}). The beam momentum for each
|
||||||
was chosen to maximise the number of stopped muons. The collected data sets are
|
target was chosen to maximise the number of stopped muons. The collected data
|
||||||
shown in Table~\ref{tb:stat}.
|
sets are shown in \cref{tb:stat}.
|
||||||
|
|
||||||
\begin{table}[htb!]
|
\begin{table}[btp!]
|
||||||
\begin{center}
|
\begin{center}
|
||||||
\vspace{0.15cm}
|
\vspace{0.15cm}
|
||||||
\begin{tabular}{l c c c}
|
\begin{tabular}{l c c c}
|
||||||
@@ -446,38 +776,39 @@ shown in Table~\ref{tb:stat}.
|
|||||||
\textbf{Target} &\textbf{Momentum} & \textbf{Run time} & \textbf{Number}\\
|
\textbf{Target} &\textbf{Momentum} & \textbf{Run time} & \textbf{Number}\\
|
||||||
\textbf{and thickness}&\textbf{scaling factor} & \textbf{(h)} &\textbf{of muons}\\
|
\textbf{and thickness}&\textbf{scaling factor} & \textbf{(h)} &\textbf{of muons}\\
|
||||||
\midrule
|
\midrule
|
||||||
Si 1500 \micro\meter& 1.32& 3.07& $2.78\times 10^7$\\
|
Si 1500 \si{\micro\meter}& 1.32& 3.07& $2.78\times 10^7$\\
|
||||||
& 1.30& 12.04& $2.89 \times 10^8$\\
|
& 1.30& 12.04& $2.89 \times 10^8$\\
|
||||||
& 1.10& 9.36& $1.37 \times 10^8$ \\
|
& 1.10& 9.36& $1.37 \times 10^8$ \\
|
||||||
\midrule
|
\midrule
|
||||||
Si 62 \micro\meter & 1.06& 10.29& $1.72 \times 10^8$\\
|
Si 62 \si{\micro\meter} & 1.06& 10.29& $1.72 \times 10^8$\\
|
||||||
\midrule
|
\midrule
|
||||||
Al 100 \micro\meter& 1.09& 14.37&$2.94 \times 10^8$\\
|
Al 100 \si{\micro\meter}& 1.09& 14.37&$2.94 \times 10^8$\\
|
||||||
& 1.07& 2.56& $4.99 \times 10^7$\\
|
& 1.07& 2.56& $4.99 \times 10^7$\\
|
||||||
\midrule
|
\midrule
|
||||||
Al 50 \micro\meter m & 1.07& 51.94& $8.81 \times 10^8$\\
|
Al 50 \si{\micro\meter} & 1.07& 51.94& $8.81 \times 10^8$\\
|
||||||
\bottomrule
|
\bottomrule
|
||||||
\end{tabular}
|
\end{tabular}
|
||||||
\end{center}
|
\end{center}
|
||||||
\caption{Run statistics. Momentum scaling
|
\caption{Run statistics. Momentum scaling factors are normalised to
|
||||||
normalized to 28 MeV/c.}
|
\SI{28}{\MeV\per\cc}.}
|
||||||
\label{tb:stat}
|
\label{tb:stat}
|
||||||
\end{table}
|
\end{table}
|
||||||
|
|
||||||
% section data_sets (end)
|
% section data_sets (end)
|
||||||
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
|
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
|
||||||
\section{Analysis framework}
|
\section{Analysis framework}
|
||||||
|
\label{sec:analysis_framework}
|
||||||
\subsection{Concept}
|
\subsection{Concept}
|
||||||
\label{sub:concept}
|
\label{sub:concept}
|
||||||
Since the AlCapDAQ is a trigger-less system, it stored all waveforms of the
|
Since the AlCapDAQ is a trigger-less system, it stored all waveforms of the
|
||||||
hits occured in 100-ms-long blocks without considering their physics
|
hits occured in 100-ms-long blocks without considering their physics
|
||||||
significance The analysis code therefore must be able to extract parameters of
|
significance. The analysis code therefore must be able to extract parameters of
|
||||||
the waveforms, then organises the pulses into physics events correlated to
|
the waveforms, then organises the pulses into the physics events correlated to
|
||||||
stopped muons (Figure~\ref{fig:muon_event}). In addition, the analyser is
|
stopped muons (\cref{fig:muon_event}). In addition, the analyser is
|
||||||
intended to be usable as a real-time component of a MIDAS DAQ, where simple
|
intended to be usable as a real-time component of a MIDAS DAQ, where simple
|
||||||
analysis could be done online for monitoring and diagnostic during the run.
|
analysis could be done online for monitoring and diagnostic during the run.
|
||||||
|
|
||||||
\begin{figure}[htb]
|
\begin{figure}[btp]
|
||||||
\centering
|
\centering
|
||||||
\includegraphics[width=0.9\textwidth]{figs/muon_event.pdf}
|
\includegraphics[width=0.9\textwidth]{figs/muon_event.pdf}
|
||||||
\caption{Concept of the AlCap analysis code: pulses from individual detector
|
\caption{Concept of the AlCap analysis code: pulses from individual detector
|
||||||
@@ -487,9 +818,9 @@ analysis could be done online for monitoring and diagnostic during the run.
|
|||||||
|
|
||||||
The analysis framework of the AlCap consists of two separate programs.
|
The analysis framework of the AlCap consists of two separate programs.
|
||||||
A MIDAS-based analyser framework, \alcapana{}, processes the raw data and
|
A MIDAS-based analyser framework, \alcapana{}, processes the raw data and
|
||||||
passes its ROOT data output to a second
|
passes its ROOT data output to the second
|
||||||
stage, \rootana{}, where most of the physics analysis is performed.
|
stage, \rootana{}, where most of the physics analysis is performed.
|
||||||
Both programs were designed to be modularised, which allowed us to develop
|
Both of the programs were designed to be modularised, which allowed us to develop
|
||||||
lightweight analysis modules that were used online to generate plots quickly,
|
lightweight analysis modules that were used online to generate plots quickly,
|
||||||
while more sophisticated modules can be applied in offline analysis.
|
while more sophisticated modules can be applied in offline analysis.
|
||||||
|
|
||||||
@@ -520,12 +851,12 @@ algorithm that takes the pulse parameters from the peak of the waveform. In
|
|||||||
parallel, a pulse finding and template fitting code is being developed because
|
parallel, a pulse finding and template fitting code is being developed because
|
||||||
it would provide more accurate pulse information. The first iteration of this
|
it would provide more accurate pulse information. The first iteration of this
|
||||||
code has been completed and is being tested.
|
code has been completed and is being tested.
|
||||||
\begin{figure}[htb]
|
%\begin{figure}[btp]
|
||||||
\centering
|
%\centering
|
||||||
\includegraphics[width=0.85\textwidth]{figs/analysis_scheme}
|
%\includegraphics[width=0.85\textwidth]{figs/analysis_scheme}
|
||||||
\caption{Concept of the analysis framework in \rootana{}}
|
%\caption{Concept of the analysis framework in \rootana{}}
|
||||||
\label{fig:rootana_scheme}
|
%\label{fig:rootana_scheme}
|
||||||
\end{figure}
|
%\end{figure}
|
||||||
|
|
||||||
After obtaining pulse parameters for individual channel, the pairing up of
|
After obtaining pulse parameters for individual channel, the pairing up of
|
||||||
fast and slow pulses from the same physical detector needs to be done. This
|
fast and slow pulses from the same physical detector needs to be done. This
|
||||||
@@ -545,7 +876,7 @@ detectors. These particle hits are still stored in the time-ordered tree
|
|||||||
corresponds to the 110 ms block length from the AlCapDAQ. By iterating through
|
corresponds to the 110 ms block length from the AlCapDAQ. By iterating through
|
||||||
the tree to find stopped muons and taking any hits within a certain window
|
the tree to find stopped muons and taking any hits within a certain window
|
||||||
around this muon from every detector, a stopped-muon-centred tree shown in
|
around this muon from every detector, a stopped-muon-centred tree shown in
|
||||||
Figure~\ref{fig:muon_event} can be produced. This will make it much easier to
|
\cref{fig:muon_event} can be produced. This will make it much easier to
|
||||||
look for coincidences and apply cuts, thereby bringing the end
|
look for coincidences and apply cuts, thereby bringing the end
|
||||||
goal of particle numbers and energy distributions.
|
goal of particle numbers and energy distributions.
|
||||||
|
|
||||||
@@ -558,8 +889,8 @@ The online analyser was developed and proved to be very useful during the run.
|
|||||||
A few basic modules were used to produce plots for diagnostic purposes
|
A few basic modules were used to produce plots for diagnostic purposes
|
||||||
including: persistency view of waveforms, pulse height
|
including: persistency view of waveforms, pulse height
|
||||||
spectra, timing correlations with respect to the upstream counters. The
|
spectra, timing correlations with respect to the upstream counters. The
|
||||||
modules and their purposes are listed in Table~\ref{tab:online_modules}.
|
modules and their purposes are listed in \cref{tab:online_modules}.
|
||||||
\begin{table}[htb]
|
\begin{table}[btp]
|
||||||
\begin{center}
|
\begin{center}
|
||||||
\begin{tabular}{l p{6cm}}
|
\begin{tabular}{l p{6cm}}
|
||||||
\toprule
|
\toprule
|
||||||
@@ -604,35 +935,142 @@ groups such as upstream counters, silicon arms. It could also periodically
|
|||||||
update the plots to reflect real-time status of the detector system.
|
update the plots to reflect real-time status of the detector system.
|
||||||
%Screen
|
%Screen
|
||||||
%shots of the {\ttfamily online-display} with several plots are shown in
|
%shots of the {\ttfamily online-display} with several plots are shown in
|
||||||
%Figure~\ref{fig:online_display}.
|
%\cref{fig:online_display}.
|
||||||
|
|
||||||
%\hl{Screen shots}
|
%\hl{Screen shots}
|
||||||
\subsection{Offline analyser}
|
\subsection{Offline analyser}
|
||||||
\label{sub:offline_analyser}
|
\label{sub:offline_analyser}
|
||||||
Some offline analysis modules has been developed during the beam time and could
|
Some offline analysis modules have been developed during the beam time and could
|
||||||
provide quick feedback in confirming and guiding the decisions at the time. For
|
provide quick feedback in confirming and guiding the decisions at the time. For
|
||||||
example, the X-ray spectrum analysis was done to confirm that we could observe
|
example, the X-ray spectrum analysis was done to confirm that we could observe
|
||||||
the muon capture process (Figure~\ref{fig:muX}), and to help in choosing optimal
|
the muon capture process and to help in choosing optimal momenta which
|
||||||
momenta which maximised the number of stopped muons.
|
maximised the number of stopped muons.
|
||||||
\begin{figure}[htbp]
|
|
||||||
\centering
|
|
||||||
\includegraphics[width=0.7\textwidth]{figs/muX.png}
|
|
||||||
\caption{Germanium
|
|
||||||
detector spectra in the range of 300 - 450 keV with different setups: no
|
|
||||||
target, 62-\micron-thick silicon target, and 100-\micron-thick aluminium
|
|
||||||
target. The ($2p-1s$) lines from
|
|
||||||
aluminium (346.828 keV) and silicon (400.177 keV) are clearly visible,
|
|
||||||
the double peaks at 431 and 438 keV are from the lead shield, the peak at
|
|
||||||
351~keV is a background gamma ray from $^{211}$Bi.}
|
|
||||||
\label{fig:muX}
|
|
||||||
\end{figure}
|
|
||||||
|
|
||||||
Although the offline analyser is still not fully developed yet, several modules
|
Although the offline analyser is still not fully available yet, several modules
|
||||||
are ready. They are described in detailed in the next chapter.
|
are ready (\cref{tab:offline_modules}). An initial analysis is possible using
|
||||||
|
the existing modules thanks to the modularity of the analysis framework.
|
||||||
|
|
||||||
|
\begin{table}[htb]
|
||||||
|
\begin{center}
|
||||||
|
\begin{tabular}{l p{8cm}}
|
||||||
|
\toprule
|
||||||
|
\textbf{Module name} & \textbf{Functions}\\
|
||||||
|
\midrule
|
||||||
|
MakeAnalysedPulses & make a pulse with parameters extracted from
|
||||||
|
a waveform\\
|
||||||
|
MaxBinAPGenerator & simplest algorithm to get pulse information\\
|
||||||
|
TSimpleMuonEvent & sort pulses occur in a fixed time window around the
|
||||||
|
muon hits\\
|
||||||
|
ExportPulse \& PulseViewer & plot waveforms for diagnostics\\
|
||||||
|
PlotAmplitude & plot pulse height spectra\\
|
||||||
|
PlotAmpVsTdiff & plot pulse correlations in timing and amplitude\\
|
||||||
|
EvdE & plot \sdEdx histograms\\
|
||||||
|
\bottomrule
|
||||||
|
\end{tabular}
|
||||||
|
\end{center}
|
||||||
|
\caption{Available offline analysis modules.}
|
||||||
|
\label{tab:offline_modules}
|
||||||
|
\end{table}
|
||||||
|
|
||||||
|
The MakeAnalysedPulses module takes a raw waveform, calculates the pedestal
|
||||||
|
from a predefined number of first samples, subtracts this pedestal taking
|
||||||
|
pulse polarity into account, then calls another module to extract pulse
|
||||||
|
parameters. At the moment, the simplest module, so-called MaxBinAPGenerator,
|
||||||
|
for pulse information calculation is in use. The module looks for the
|
||||||
|
sample that has the maximal deviation from the baseline, takes the deviation as
|
||||||
|
pulse amplitude and the time stamp of the sample as pulse time. The procedure
|
||||||
|
is illustrated on \cref{fig:tap_maxbin_algo}. This module could not handle
|
||||||
|
pile-up or double pulses in one \tpulseisland{} in \cref{fig:tap_maxbin_bad}.
|
||||||
|
\begin{figure}[htb]
|
||||||
|
\centering
|
||||||
|
\includegraphics[width=0.85\textwidth]{figs/tap_maxbin_algo}
|
||||||
|
\caption{Pulse parameters extraction with MaxBinAPGenerator.}
|
||||||
|
\label{fig:tap_maxbin_algo}
|
||||||
|
\end{figure}
|
||||||
|
\begin{figure}[htb]
|
||||||
|
\centering
|
||||||
|
\includegraphics[width=0.47\textwidth]{figs/tap_maxbin_bad}
|
||||||
|
\includegraphics[width=0.47\textwidth]{figs/tap_maxbin_bad2}
|
||||||
|
\caption{Double pulse and pile up are taken as one single pulse by the
|
||||||
|
MaxBinAPGenerator}
|
||||||
|
\label{fig:tap_maxbin_bad}
|
||||||
|
\end{figure}
|
||||||
|
|
||||||
|
The TSimpleMuonEvent first picks a muon candidate, then loops through all
|
||||||
|
pulses on all detector channels, and picks all pulses occur in
|
||||||
|
a time window of \SI{\pm 10}{\si{\us}} around each candidate to build
|
||||||
|
a muon event. A muon candidate is a hit on the upstream plastic scintillator
|
||||||
|
with an amplitude higher than a threshold which was chosen to reject MIPs. The
|
||||||
|
period of \SI{10}{\si{\us}} is long enough compared to the mean life time of
|
||||||
|
muons in the target materials
|
||||||
|
(\SI{0.758}{\si{\us}} for silicon, and \SI{0.864}{\si{\us}}
|
||||||
|
for aluminium~\cite{SuzukiMeasday.etal.1987}) so practically all of emitted
|
||||||
|
charged particles would be recorded in this time window.
|
||||||
|
%\begin{figure}[htb]
|
||||||
|
%\centering
|
||||||
|
%\includegraphics[width=0.85\textwidth]{figs/tme_musc_threshold}
|
||||||
|
%\caption{Pulse height spectrum of the $\mu$Sc scintillator}
|
||||||
|
%\label{fig:tme_musc_threshold}
|
||||||
|
%\end{figure}
|
||||||
|
|
||||||
|
A pile-up protection mechanism is employed to reject multiple muons events: if
|
||||||
|
there exists another muon hit in less than \SI{15}{\us} from the
|
||||||
|
candidate then both the candidate and the other muon are discarded. This
|
||||||
|
pile-up protection would cut out less than 11\% total number of events because
|
||||||
|
the beam rate was generally less than \SI{8}{\kilo\hertz}.
|
||||||
|
|
||||||
|
%In runs with active silicon targets, another requirement is applied for the
|
||||||
|
%candidate: a prompt hit on the target in $\pm 200$ \si{\ns}\ around the
|
||||||
|
%time of the $\mu$Sc pulse. The number comes from the observation of the
|
||||||
|
%time correlation between hits on the target and the $\mu$Sc
|
||||||
|
%(\cref{fig:tme_sir_prompt_rational}).
|
||||||
|
%\begin{figure}[htb]
|
||||||
|
%\centering
|
||||||
|
%\includegraphics[width=0.85\textwidth]{figs/tme_sir_prompt_rational}
|
||||||
|
%\caption{Correlation in time between SiR2 hit and muon hit}
|
||||||
|
%\label{fig:tme_sir_prompt_rational}
|
||||||
|
%\end{figure}
|
||||||
|
|
||||||
|
To make sure that we will analyse good data, a low level data quality checking
|
||||||
|
was done on the whole data sets. The idea is to plot the variations of basic
|
||||||
|
parameters, such as noise level, length of raw waveforms, pulse rate, time
|
||||||
|
correlation to hits on the muon counter on each channel during the data
|
||||||
|
collecting period. Runs with significant difference from the averaging
|
||||||
|
values were further checked for possible causes, and would be discarded if such
|
||||||
|
discrepancy was too large or unaccounted for. Examples of such trend plots are
|
||||||
|
shown in \cref{fig:lldq}.
|
||||||
|
\begin{figure}[htb]
|
||||||
|
\centering
|
||||||
|
\includegraphics[width=0.47\textwidth]{figs/lldq_noise}
|
||||||
|
\includegraphics[width=0.47\textwidth]{figs/lldq_tdiff}
|
||||||
|
\caption{Example trend plots used in the low level data quality checking:
|
||||||
|
noise level in FWHM (left) and time correlation with muon hits (right).
|
||||||
|
The horizontal axis is run number, the vertical axis is the channel name
|
||||||
|
(left), or the time difference between hit in the germanium
|
||||||
|
detector and a hit in upstream counter (right). Colors in both plots
|
||||||
|
indicate the number of events. In the left plot, the
|
||||||
|
noise level was basically stable in in this data set, except for one
|
||||||
|
channel where there was a sudden jump in a range of runs. On the right hand
|
||||||
|
side, this sanity check helped find out the sampling frequency was wrongly
|
||||||
|
applied in the first tranche of the data
|
||||||
|
set.}
|
||||||
|
\label{fig:lldq}
|
||||||
|
\end{figure}
|
||||||
% subsection offline_analyser (end)
|
% subsection offline_analyser (end)
|
||||||
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
|
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
|
||||||
% section analysis_strategy (end)
|
\section{Monte Carlo simulation}
|
||||||
|
\label{sec:monte_carlo_simulation}
|
||||||
|
|
||||||
|
A full Monte Carlo (MC) simulation of the experimental set up has been developed
|
||||||
|
based on Geant4~\cite{Agostinelli.etal.2003}. The geometrical implementation
|
||||||
|
was detailed as much as possible and could be modified via configuration
|
||||||
|
scripts at run time. Descriptions of the muon beam came from the beam line optic
|
||||||
|
calculation provided by the accelerator experts at PSI.
|
||||||
|
|
||||||
|
The MC model greatly assisted the design of the experiment, such as alignment
|
||||||
|
of the detectors with respect to the target, and shielding of scattered muons.
|
||||||
|
It also helped make a sense of the observed results during the run and data
|
||||||
|
analysing.
|
||||||
|
|
||||||
% chapter the_alcap_run_2013 (end)
|
% chapter the_alcap_run_2013 (end)
|
||||||
|
|
||||||
|
|||||||
File diff suppressed because it is too large
Load Diff
@@ -1,74 +1,154 @@
|
|||||||
\chapter{Discussions}
|
\chapter{Impact to the COMET Phase-I}
|
||||||
\label{cha:discussions}
|
\label{cha:discussions_on_the_impact_to_the_comet_phase_i}
|
||||||
|
The measured proton emission rate of 3.5\% is about 5 times
|
||||||
|
smaller than the figure using to make the baseline design of the CDC in COMET
|
||||||
|
Phase-I. The spectrum shape is softer than that of silicon,
|
||||||
|
peaks around \SI{4}{\MeV} rather than at \SI{2.5}{\MeV}
|
||||||
|
(\cref{fig:sobottka_spec}). Therefore CDC hit rate due to proton should be
|
||||||
|
smaller than the current estimation.
|
||||||
|
|
||||||
\section{Thick aluminium target measurement}
|
The CDC proton hit rate is calculated by a toy MC study. The dimensions of the
|
||||||
\label{sub:active_target_measurement}
|
geometry shown in \cref{fig:cdc_toy_mc} are from \cref{ssub:CDC_configuration}.
|
||||||
With a thick and active silicon target, I have tried to reproduce an existing
|
The inner wall of the CDC is \SI{0.5}{\mm} thick CFRP.
|
||||||
result from Sobottka and Wills~\cite{SobottkaWills.1968}. This is important in
|
A proton absorber made
|
||||||
giving confidence in our experimental method. The idea is the same as that of
|
of CFRP is placed \SI{5}{\cm} far from the inner wall of the CDC. The
|
||||||
the old measurement, where muons were stopped inside a bulk active target and
|
absorber's thickness is varied from 0 (no absorber) to \SI{1}{\mm}.
|
||||||
the capture products were measured. Due to the limitation of the
|
\begin{figure}[htb]
|
||||||
currently available analysis tool, a direct comparison with the result of
|
\centering
|
||||||
Sobottka and Wills is not practical at the moment.
|
\includegraphics[width=0.55\textwidth]{figs/cdc_toy_mc}
|
||||||
|
\caption{Geometry of the toy MC study for hit rate study.}
|
||||||
|
\label{fig:cdc_toy_mc}
|
||||||
|
\end{figure}
|
||||||
|
|
||||||
But a partial comparison is available for a part of the spectrum from 8 to
|
The protons with the energy spectrum shape as in
|
||||||
10~MeV, where my result of $(1.22 \pm 0.19) \times 10^{-2} $ is consistent with
|
\cref{sub:proton_emission_rate} are generated inside the COMET's muon stopping
|
||||||
the derived value $(1.28\pm0.19)\times10^{-2}$ from the paper of Sobottka and
|
targets which are 17 200-\si{\um}-thick aluminium discs. The spatial
|
||||||
Wills. The agreement was partly because of large error bars in both results.
|
distribution of protons resembles the stopping distribution of muons inside the
|
||||||
In my part, the largest error came from the uncertainty on choosing the
|
target discs calculated from the full MC simulation of the COMET detectors
|
||||||
integration window. This can be solved with a more sophisticated pulse
|
(\cref{fig:cdc_toy_mc_init_pos}).
|
||||||
finding/calculating algorithm so that the contribution of muons in the energy
|
\begin{figure}[htb]
|
||||||
spectrum can be eliminated by imposing a cut in pulse timing. The
|
\centering
|
||||||
under-testing pulse template fitting module could do this job soon.
|
\includegraphics[width=0.65\textwidth]{figs/cdc_toy_mc_init_pos_xy}
|
||||||
|
\includegraphics[width=0.60\textwidth]{figs/cdc_toy_mc_init_pos_z}
|
||||||
|
\caption{Spatial distribution of the generated protons in X, Y (top) and
|
||||||
|
Z (bottom). Z is the axis of the CDC, X, Y are the horizontal and vertical
|
||||||
|
axes respectively.}
|
||||||
|
\label{fig:cdc_toy_mc_init_pos}
|
||||||
|
\end{figure}
|
||||||
|
|
||||||
The range of 8--10~MeV was chosen to be large enough so that the uncertainty of
|
The protons are then tracked in a \SI{1}{\tesla} magnetic field. The protons
|
||||||
integration window would not to be too great; and at the same time be small
|
reaching the absorber, inner wall and the sensitive volume of the CDC are
|
||||||
enough so the protons (and other heavier charged particles) would not escape
|
recorded (see \cref{fig:cdc_toy_mc_p_spec_500um}).
|
||||||
the active target. This range is also more convenient for calculating the
|
\begin{figure}[!htb]
|
||||||
partial rate from the old paper of Sobottka and Wills.
|
\centering
|
||||||
|
\includegraphics[width=0.75\textwidth]{figs/cdc_toy_mc_p_spec_500um}
|
||||||
|
\caption{Proton energy spectra at different stages from birth to the
|
||||||
|
sensitive volume of the CDC. The baseline design of \SI{0.5}{\mm} thick
|
||||||
|
absorber and \SI{0.5}{\mm} thick inner wall was used to produce this
|
||||||
|
plot.}
|
||||||
|
\label{fig:cdc_toy_mc_p_spec_500um}
|
||||||
|
\end{figure}
|
||||||
|
|
||||||
% section protons_following_muon_capture_on_silicon (end)
|
A muon stopping rate of \SI{1.3E9}{\Hz} is assumed as in the COMET Phase I's
|
||||||
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
|
TDR. The number of proton emitted is then $\num{1.3E9} \times 0.609 \times
|
||||||
|
0.035 = \SI{2.8E7}{\Hz}$. The hit rates on a single cell in the inner most
|
||||||
|
layer due to these protons with
|
||||||
|
different absorber configurations are listed in
|
||||||
|
\cref{tab:proton_cdc_hitrate_comp}.
|
||||||
|
|
||||||
\section{Thin silicon target measurement}
|
\begin{table}[htb]
|
||||||
\label{sub:thin_and_passive_target_measurement}
|
\begin{center}
|
||||||
The charged particles in the low energy region of 2.5--8~MeV were measured by
|
\begin{tabular}{S S S S S}
|
||||||
dE/dx method. The particle identification was good in lower energy part, but
|
\toprule
|
||||||
losing its resolution power as energy increases. The current set up could do
|
{\textbf{Absorber}} &{\textbf{Inner wall}} & {\textbf{Total CFRP}}&
|
||||||
the PID up to about 8~MeV for protons. This energy range is exactly the
|
{\textbf{Proton hit rate}} & {\textbf{Proton hit rate}}\\
|
||||||
relevant range to the COMET experiment (Figure~\ref{fig:proton_impact_CDC}).
|
{\textbf{thickness}} &{\textbf{thickness}} & {\textbf{thickness}}&
|
||||||
|
{\textbf{Phase-I TDR}} & {\textbf{New estimation}}\\
|
||||||
|
{(\si{\mm})} & {(\si{\mm})} & {(\si{\mm})} & {(\si{\Hz})}& {(\si{\Hz})}\\
|
||||||
|
\midrule
|
||||||
|
1 &0.5&1.5 & 4E+3 & 2 \\
|
||||||
|
0.5 &0.5&1.0 & 11E+3& 126 \\
|
||||||
|
0 &0.5&0.5 & 30E+3& 1436 \\
|
||||||
|
\bottomrule
|
||||||
|
\end{tabular}
|
||||||
|
\end{center}
|
||||||
|
\caption{CDC proton hit rates in this study in comparison with the expected
|
||||||
|
rates in COMET Phase-I's Technical Design Report~\cite{COMET.2014} at
|
||||||
|
different configurations of proton absorber and inner wall.}
|
||||||
|
\label{tab:proton_cdc_hitrate_comp}
|
||||||
|
\end{table}
|
||||||
|
|
||||||
In that useful energy range, the analysis showed a good separation of protons
|
%\begin{table}[htb]
|
||||||
from other heavy charged particles. The contribution of protons in the total
|
%\begin{center}
|
||||||
charged particles is 87\%. This is the high limit only since the heavier
|
%\begin{tabular}{S S S S S S}
|
||||||
particles at this energy range are most likely to stopped in the thin
|
%\toprule
|
||||||
detectors. More statistic would be needed to estimate the contributions from
|
%{\textbf{Absorber}} &{\textbf{Inner wall}} & {\textbf{Total CFRP}}& {\textbf{Proton}} & {\textbf{Momentum}} & {\textbf{Integrated charge}}\\
|
||||||
other particles.
|
%{\textbf{thickness}} &{\textbf{thickness}} & {\textbf{thickness}}& {\textbf{hit rate}} &{\textbf{spread $\Delta p$}} &{\textbf{300 days}}\\
|
||||||
|
%{(\si{\mm})} & {(\si{\mm})} & {(\si{\mm})} & {(\si{\Hz})} & {(\si{\keV\per\cc)}} &{(mC/cm)}\\
|
||||||
|
%\midrule
|
||||||
|
%1 &0.5&1.5 & 2 & 195 & 25\\
|
||||||
|
%0.5 &0.5&1.0 & 126 & 167 & 60\\
|
||||||
|
%0 &0.5&0.5 & 1436 & 133 & 160\\
|
||||||
|
%\bottomrule
|
||||||
|
%\end{tabular}
|
||||||
|
%\end{center}
|
||||||
|
%\caption{CDC proton hit rates at different configuration of proton absorber
|
||||||
|
%and inner wall. The momentum spreads for \SI{0.5}{\mm} thick inner wall are
|
||||||
|
%taken from \cref{tab:comet_absorber_impact}.}
|
||||||
|
%\end{table}
|
||||||
|
At the baseline design of \SI{0.5}{\mm}, the hit rate is only \SI{126}{\Hz},
|
||||||
|
much smaller than the current estimation at \SI{11}{\kHz}. Even without the
|
||||||
|
absorber, proton hit rate remains lower than that level at \SI{1.4}{\kHz}.
|
||||||
|
Therefore the absorber is not necessary as far as the hit rate is concerned.
|
||||||
|
%Therefore a proton
|
||||||
|
%absorber is not needed for the COMET Phase I's CDC.
|
||||||
|
|
||||||
The effective emission rate of protons per muon capture in this measurement is
|
If the proton absorber is not used, the momentum spread of the signal electron
|
||||||
4.20\%, with a large uncertainty contribution comes from limitation of the
|
reduces from \SI{167}{\keV\per\cc} to \SI{131}{\keV\per\cc} (\cref{tab:proton_cdc_hitrate}).
|
||||||
timing determination. The spectral integral in the region 2.5--8~MeV on
|
This is a small improvement since the momentum resolution is dominated by
|
||||||
Figure~\ref{fig:sobottka_spec} is about 70\% of the spectrum from 1.4 to
|
intrinsic spread of \SI{197}{\keV\per\cc} due to multiple scattering in gas
|
||||||
26~\MeV, and corresponds to an emission rate of about 10\% per muon capture.
|
and wires.
|
||||||
The two figures are not in disagreement.
|
|
||||||
|
|
||||||
In order to have a better comparison, a correction or unfolding for energy
|
|
||||||
loss and more MC simulation study are needed. I am on progress of these study.
|
|
||||||
|
|
||||||
% subsection thin_and_passive_target_measurement (end)
|
|
||||||
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
|
|
||||||
\section{Aluminium target measurement}
|
|
||||||
\label{sec:aluminium_target_measurement}
|
|
||||||
The proton emission rate was derived as 2.37\%, but the problem on the SiL1-1
|
|
||||||
channel was not solved yet. One possible cause is the muons captured on other
|
|
||||||
lighter material inside the chamber. More investigation will be made on this
|
|
||||||
matter.
|
|
||||||
|
|
||||||
The rate of 2.37\% on aluminium appears to be smaller on that of silicon but
|
|
||||||
the two results are both effective rates, modified by energy loss inside the
|
|
||||||
target. Unfolding and MC study for the correction are ongoing.
|
|
||||||
% section aluminium_target_measurement (end)
|
|
||||||
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
|
|
||||||
% chapter discussions (end)
|
|
||||||
|
|
||||||
|
The last column of \cref{tab:proton_cdc_hitrate} shows the integrated charge
|
||||||
|
per unit length of a wire. The TDR deems an integrated charge level of
|
||||||
|
\SI{200}{\milli\coulomb\per\cm} safe. So even with the pessimistic estimation using
|
||||||
|
silicon rate and spectrum and without the proton absorber, the integrated
|
||||||
|
charge level in the CDC is still below the requirement. Therefore removing the
|
||||||
|
absorber will not worsen the ageing process of the wires.
|
||||||
|
\begin{table}[htb]
|
||||||
|
\begin{center}
|
||||||
|
\begin{tabular}{S S S S S}
|
||||||
|
\toprule
|
||||||
|
{\textbf{Absorber}} &{\textbf{Inner wall}} & {\textbf{Total CFRP}}&
|
||||||
|
{\textbf{Momentum}} & {\textbf{Integrated charge}}\\
|
||||||
|
{\textbf{thickness}} &{\textbf{thickness}} & {\textbf{thickness}}&
|
||||||
|
{\textbf{spread $\Delta p$}} &{\textbf{300 days}}\\
|
||||||
|
{(\si{\mm})} & {(\si{\mm})} & {(\si{\mm})}
|
||||||
|
& {(\si{\keV\per\cc)}} &{(mC/cm)}\\
|
||||||
|
\midrule
|
||||||
|
1 &0.5&1.5 & 195 & 25\\
|
||||||
|
0.5 &0.5&1.0 & 167 & 60\\
|
||||||
|
0 &0.5&0.5 & 133 & 160\\
|
||||||
|
%0 &0.3&0.3 & 8281 & {-} & {-}\\
|
||||||
|
%0 &0.1&0.1 & 15011& {-} & {-}\\
|
||||||
|
\bottomrule
|
||||||
|
\end{tabular}
|
||||||
|
\end{center}
|
||||||
|
\caption{Momentum spreads due to the inner wall and absorber, and integrated
|
||||||
|
charge per unit length of wire as calculated in the COMET Phase-I's TDR.
|
||||||
|
The momentum spreads were calculated for signal electrons at
|
||||||
|
\SI{104.96}{\MeV\per\cc}. The integrated charge is estimated assuming 300
|
||||||
|
days of operation.}
|
||||||
|
\label{tab:proton_cdc_hitrate}
|
||||||
|
\end{table}
|
||||||
|
|
||||||
|
%In case a lower momentum spread is desired, it is possible to reduce the
|
||||||
|
%thickness of the inner wall. The last
|
||||||
|
%two rows of \cref{tab:proton_cdc_hitrate} show that even with thinner walls at
|
||||||
|
%\SI{0.3}{\mm} and \SI{0.1}{\mm} the hit rate by protons are still at
|
||||||
|
%manageable levels. However, reducing the wall thickness would be governed by
|
||||||
|
%other requirements such as mechanical structure and gas-tightness.
|
||||||
|
In summary, the toy MC study with the preliminary proton rate and spectrum
|
||||||
|
shows that a proton absorber is not needed. It confirms the known fact that the
|
||||||
|
estimation used in COMET Phase-I is conservative, and provides a solid
|
||||||
|
prediction of the hit rate caused by protons.
|
||||||
|
|||||||
47
thesis/chapters/chap8_conclusions.tex
Normal file
47
thesis/chapters/chap8_conclusions.tex
Normal file
@@ -0,0 +1,47 @@
|
|||||||
|
\chapter{Conclusions}
|
||||||
|
\label{cha:conclusions}
|
||||||
|
The AlCap is an experiment proposed at PSI to study charged particles, neutrons
|
||||||
|
and photons emitting after nuclear muon capture on aluminium. These
|
||||||
|
measurements are important for backgrounds and hit rates estimation of the new
|
||||||
|
generation of \mueconv experiments, COMET and Mu2e. In the first stage of the
|
||||||
|
COMET experiment, hit rate on its main tracking detector is anticipated to be
|
||||||
|
dominated by low energy protons following muon capture on an aluminium target,
|
||||||
|
which has never been measured.
|
||||||
|
|
||||||
|
The first run of the AlCap which aims for proton measurement has been carried
|
||||||
|
out in 2013. Data analysis is in progress. Before finishing the complete AlCap
|
||||||
|
analysis, an initial analysis on partial data
|
||||||
|
was made. The main results are:
|
||||||
|
\begin{enumerate}
|
||||||
|
\item demonstration of the analysis chain from trigger-less waveforms to
|
||||||
|
correlated physics events;
|
||||||
|
\item validation of the experimental method including: number of nuclear
|
||||||
|
capture muons normalisation by muonic X-ray measurement, charged particle
|
||||||
|
identification by specific energy loss, and unfolding of the proton energy
|
||||||
|
spectrum using the iterative Bayesian method;
|
||||||
|
\item obtaining preliminary results on proton emission rate and spectrum:
|
||||||
|
the proton spectrum has a peak at \SI{3.7}{\MeV}, then reduces exponentially
|
||||||
|
with a decay constant of \SI{2.6}{\MeV}. The partial emission rate in the
|
||||||
|
energy range from \SIrange{4}{8}{\MeV} is $(1.7 \pm 0.1)\%$ per nuclear
|
||||||
|
muon capture, and the total
|
||||||
|
emission rate assuming the shape holds for the whole spectrum is
|
||||||
|
$(3.5\pm0.2)\%$ per nuclear muon capture.
|
||||||
|
\end{enumerate}
|
||||||
|
The emission rate is consistent with the lower limit of 2.8\% set by
|
||||||
|
Wyttenbach et al.~\cite{WyttenbachBaertschi.etal.1978}. It is also compatible
|
||||||
|
with the theoretical calculation by Lifshitz and
|
||||||
|
Singer~\cite{LifshitzSinger.1980}. Compared with the existing result on
|
||||||
|
silicon~\cite{SobottkaWills.1968}, the emission rate from aluminium is
|
||||||
|
significantly smaller and the spectrum is softer.
|
||||||
|
|
||||||
|
The proton rate and spectrum have been used to optimise the planned proton
|
||||||
|
absorber for the drift chamber of the COMET Phase-I. The resulted proton hit
|
||||||
|
rate with the baseline configuration is very small compared with the current
|
||||||
|
figure.The recommendation to the COMET Phase-I is to remove the proton
|
||||||
|
absorber altogether. The momentum resolution of the drift chamber will be
|
||||||
|
slightly improved, and the level of integrated charge will still remain below
|
||||||
|
the safe level for the chamber.
|
||||||
|
|
||||||
|
The AlCap experiment is going to
|
||||||
|
submit a beam time request for the 2015 run to collect more data and other
|
||||||
|
measurements for neutrons and gamma rays.
|
||||||
@@ -10,11 +10,11 @@ Osaka University}
|
|||||||
\begin{abstract}
|
\begin{abstract}
|
||||||
%[\smaller \thetitle\\ \vspace*{1cm} \smaller {\theauthor}]
|
%[\smaller \thetitle\\ \vspace*{1cm} \smaller {\theauthor}]
|
||||||
\thispagestyle{empty}
|
\thispagestyle{empty}
|
||||||
COMET [1] is an experiment that aims to search for a charged lepton flavor
|
COMET [1] is an experiment that aims to search for a charged lepton flavour
|
||||||
violation (CLFV) process, the muon-to-electron conversion in the presence of
|
violation (CLFV) process, the muon-to-electron conversion in the presence of
|
||||||
a nucleus,
|
a nucleus,
|
||||||
\muec. The process is forbidden in the Standard Model (SM), however is
|
\muec. The process is forbidden in the Standard Model (SM), however is
|
||||||
predicted to occur in various extensions of SM, such as . Current experimental
|
predicted to occur in various extensions of SM. Current experimental
|
||||||
upper limit of the branching ratio is $BR(\mu^{-} + Au \rightarrow e^{-} + Au)
|
upper limit of the branching ratio is $BR(\mu^{-} + Au \rightarrow e^{-} + Au)
|
||||||
< 7 \times 10^{-13}$, set by the SINDRUM II experiment [2].
|
< 7 \times 10^{-13}$, set by the SINDRUM II experiment [2].
|
||||||
|
|
||||||
@@ -25,11 +25,21 @@ approach in which the first phase, COMET Phase-I [3], starts in 2013 and
|
|||||||
initial data taking in around 2017.
|
initial data taking in around 2017.
|
||||||
|
|
||||||
In order to optimize detector design for the Phase-I, backgrounds from nuclear
|
In order to optimize detector design for the Phase-I, backgrounds from nuclear
|
||||||
muon capture are crucial. We have proposed a dedicated experiment , namely
|
muon capture are crucial. We have proposed a dedicated experiment, namely
|
||||||
AlCap, at PSI, Switzerland to study the backgrounds, including: heavy charged
|
AlCap, at PSI, Switzerland to study the backgrounds, including protons,
|
||||||
particles, neutrons and photons. The measurements of heavy charged particles
|
neutrons and photons. The measurements of proton rate and spectrum on
|
||||||
have been carried out in the 2013 run and the preliminary analysis results are
|
aluminium have been carried out in the 2013 run. The second run to study
|
||||||
presented in this thesis.
|
neutrons and photons is planned in 2015.
|
||||||
|
|
||||||
|
The preliminary results from the analysis of the 2013 run are presented in this
|
||||||
|
thesis. The measured proton spectrum peaks at \SI{3.7}{\MeV} and decays
|
||||||
|
exponentially with the decay constant of \SI{2.6}{\MeV}. The emission
|
||||||
|
rate of protons in the energy range from \SIrange{4}{8}{\MeV} is
|
||||||
|
$(1.7\pm0.1)\%$. The total proton emission rate is estimated to be
|
||||||
|
$(3.5\pm0.2)\%$ assuming the spectrum shape holds.
|
||||||
|
The resulted proton rate and spectrum were used to optimise the tracking
|
||||||
|
detector hit rate of the COMET Phase-I.
|
||||||
|
|
||||||
\end{abstract}
|
\end{abstract}
|
||||||
|
|
||||||
|
|
||||||
@@ -47,18 +57,34 @@ presented in this thesis.
|
|||||||
|
|
||||||
|
|
||||||
% Acknowledgements
|
% Acknowledgements
|
||||||
%\begin{acknowledgements}
|
\begin{acknowledgements}
|
||||||
%\thispagestyle{empty}
|
\thispagestyle{empty}
|
||||||
%Of the many people who deserve thanks, some are particularly prominent,
|
First and foremost I would like to thank my supervisor Yoshitaka
|
||||||
%such as my supervisor Professor Yoshitaka Kuno.
|
Kuno, for his great support and almost infinite patience in last four years.
|
||||||
%\end{acknowledgements}
|
I am also grateful to all members of the Kuno group, Department of
|
||||||
|
Physics, Osaka University. Thanks to Akira Sato, Hideyuki Sakamoto for the
|
||||||
|
knowledge and supervision they have provided. And to Takahisa Itahashi
|
||||||
|
for the advice and allowing me to practice on his expensive silicon detectors.
|
||||||
|
|
||||||
|
The measurement described in this thesis is the product of effort of all
|
||||||
|
members of the AlCap Collaboration. Special thanks to Peter Kammel for
|
||||||
|
always pushing the experiment forward and your very helpful advices.
|
||||||
|
I enjoyed the stays at your group at University of Washington in Seattle
|
||||||
|
a lot. I would also like to thank the
|
||||||
|
fellow graduate students in the collaboration Andy, John, Ben, Damien for
|
||||||
|
all the hard work in the beam time, in the analysis phase, and also for
|
||||||
|
the beers. I wish you all success with your work.
|
||||||
|
|
||||||
|
Finally, I would like to thank my family and friends. Without your love and
|
||||||
|
support I wouldn't make it through these long years of graduate school.
|
||||||
|
\end{acknowledgements}
|
||||||
|
|
||||||
|
|
||||||
%% Preface
|
%% Preface
|
||||||
%\begin{preface}
|
%\begin{preface}
|
||||||
%\thispagestyle{empty}
|
%\thispagestyle{empty}
|
||||||
%The thesis is about measurements of products of nuclear muon capture on an
|
%The thesis is about measurements of products of nuclear muon capture on an
|
||||||
%aluminum target, which is important for optimization of a tracking detector
|
%aluminium target, which is important for optimization of a tracking detector
|
||||||
%of a search for muon to electron conversion, the E21 experiment - so called
|
%of a search for muon to electron conversion, the E21 experiment - so called
|
||||||
%COMET - at Japan Proton Accelerator Complex (J-PARC).
|
%COMET - at Japan Proton Accelerator Complex (J-PARC).
|
||||||
%\end{preface}
|
%\end{preface}
|
||||||
|
|||||||
@@ -50,6 +50,9 @@ $\mu^- \rightarrow e^- \nu_\mu \overline{\nu}_e e^+ e^-$\xspace
|
|||||||
|
|
||||||
\newcommand{\cc}{$c$\xspace}
|
\newcommand{\cc}{$c$\xspace}
|
||||||
|
|
||||||
|
\newcommand{\dEdx}{$\dfrac{\mathop{dE}}{\mathop{dx}}$\xspace}
|
||||||
|
\newcommand{\sdEdx}{$\sfrac{\mathop{dE}}{\mathop{dx}}$\xspace}
|
||||||
|
|
||||||
\newcommand{\rootana}{{\ttfamily rootana}}
|
\newcommand{\rootana}{{\ttfamily rootana}}
|
||||||
\newcommand{\alcapana}{{\ttfamily alcapana}}
|
\newcommand{\alcapana}{{\ttfamily alcapana}}
|
||||||
\newcommand{\tpulseisland}{{\ttfamily TPulseIsland}}
|
\newcommand{\tpulseisland}{{\ttfamily TPulseIsland}}
|
||||||
|
|||||||
BIN
thesis/figs/al100_dedx.pdf
Normal file
BIN
thesis/figs/al100_dedx.pdf
Normal file
Binary file not shown.
BIN
thesis/figs/al100_ge_spec.pdf
Normal file
BIN
thesis/figs/al100_ge_spec.pdf
Normal file
Binary file not shown.
BIN
thesis/figs/al100_mu_stop_mc.pdf
Normal file
BIN
thesis/figs/al100_mu_stop_mc.pdf
Normal file
Binary file not shown.
BIN
thesis/figs/al100_proton_lifetime.pdf
Normal file
BIN
thesis/figs/al100_proton_lifetime.pdf
Normal file
Binary file not shown.
BIN
thesis/figs/al100_proton_lifetime_sil11.pdf
Normal file
BIN
thesis/figs/al100_proton_lifetime_sil11.pdf
Normal file
Binary file not shown.
BIN
thesis/figs/al100_proton_lifetime_wosil11.pdf
Normal file
BIN
thesis/figs/al100_proton_lifetime_wosil11.pdf
Normal file
Binary file not shown.
BIN
thesis/figs/al100_proton_spec.pdf
Normal file
BIN
thesis/figs/al100_proton_spec.pdf
Normal file
Binary file not shown.
BIN
thesis/figs/al100_proton_spec_wosil11.pdf
Normal file
BIN
thesis/figs/al100_proton_spec_wosil11.pdf
Normal file
Binary file not shown.
BIN
thesis/figs/al100_protons.pdf
Normal file
BIN
thesis/figs/al100_protons.pdf
Normal file
Binary file not shown.
BIN
thesis/figs/al100_protons_px_r.pdf
Normal file
BIN
thesis/figs/al100_protons_px_r.pdf
Normal file
Binary file not shown.
BIN
thesis/figs/al100_resp.pdf
Normal file
BIN
thesis/figs/al100_resp.pdf
Normal file
Binary file not shown.
BIN
thesis/figs/al100_scan_rate.pdf
Normal file
BIN
thesis/figs/al100_scan_rate.pdf
Normal file
Binary file not shown.
BIN
thesis/figs/al100_selection.pdf
Normal file
BIN
thesis/figs/al100_selection.pdf
Normal file
Binary file not shown.
BIN
thesis/figs/al100_xray_fit.pdf
Normal file
BIN
thesis/figs/al100_xray_fit.pdf
Normal file
Binary file not shown.
BIN
thesis/figs/al100_xray_musc.pdf
Normal file
BIN
thesis/figs/al100_xray_musc.pdf
Normal file
Binary file not shown.
BIN
thesis/figs/alcapdaq_pcs.pdf
Normal file
BIN
thesis/figs/alcapdaq_pcs.pdf
Normal file
Binary file not shown.
BIN
thesis/figs/alcapdaq_scheme.pdf
Normal file
BIN
thesis/figs/alcapdaq_scheme.pdf
Normal file
Binary file not shown.
BIN
thesis/figs/analysis_scheme.pdf
Normal file
BIN
thesis/figs/analysis_scheme.pdf
Normal file
Binary file not shown.
BIN
thesis/figs/beam.pdf
Normal file
BIN
thesis/figs/beam.pdf
Normal file
Binary file not shown.
BIN
thesis/figs/cdc_toy_mc.png
Normal file
BIN
thesis/figs/cdc_toy_mc.png
Normal file
Binary file not shown.
|
After Width: | Height: | Size: 111 KiB |
BIN
thesis/figs/charged_particles_1usec_Al100.pdf
Normal file
BIN
thesis/figs/charged_particles_1usec_Al100.pdf
Normal file
Binary file not shown.
BIN
thesis/figs/dEdx_Al100_half_0-6us.pdf
Normal file
BIN
thesis/figs/dEdx_Al100_half_0-6us.pdf
Normal file
Binary file not shown.
BIN
thesis/figs/dEdx_Al100_half_1-6us.pdf
Normal file
BIN
thesis/figs/dEdx_Al100_half_1-6us.pdf
Normal file
Binary file not shown.
BIN
thesis/figs/dEdx_Al100_half_2-6us.pdf
Normal file
BIN
thesis/figs/dEdx_Al100_half_2-6us.pdf
Normal file
Binary file not shown.
BIN
thesis/figs/dEdx_Si16vsAl100.pdf
Normal file
BIN
thesis/figs/dEdx_Si16vsAl100.pdf
Normal file
Binary file not shown.
BIN
thesis/figs/dEdx_Si16vsAl100_left.pdf
Normal file
BIN
thesis/figs/dEdx_Si16vsAl100_left.pdf
Normal file
Binary file not shown.
BIN
thesis/figs/ge_cal_rate_pulselength.pdf
Normal file
BIN
thesis/figs/ge_cal_rate_pulselength.pdf
Normal file
Binary file not shown.
BIN
thesis/figs/ge_ecal_eff.pdf
Normal file
BIN
thesis/figs/ge_ecal_eff.pdf
Normal file
Binary file not shown.
BIN
thesis/figs/ge_ecal_fwhm.pdf
Normal file
BIN
thesis/figs/ge_ecal_fwhm.pdf
Normal file
Binary file not shown.
BIN
thesis/figs/ge_eff_cal.pdf
Normal file
BIN
thesis/figs/ge_eff_cal.pdf
Normal file
Binary file not shown.
BIN
thesis/figs/ge_eff_mc_finitesize_vs_pointlike.png
Normal file
BIN
thesis/figs/ge_eff_mc_finitesize_vs_pointlike.png
Normal file
Binary file not shown.
|
After Width: | Height: | Size: 103 KiB |
BIN
thesis/figs/ge_eff_mc_finitesize_vs_pointlike_root.pdf
Normal file
BIN
thesis/figs/ge_eff_mc_finitesize_vs_pointlike_root.pdf
Normal file
Binary file not shown.
BIN
thesis/figs/ge_eu152_fwhm.pdf
Normal file
BIN
thesis/figs/ge_eu152_fwhm.pdf
Normal file
Binary file not shown.
BIN
thesis/figs/ge_eu152_spec_.pdf
Normal file
BIN
thesis/figs/ge_eu152_spec_.pdf
Normal file
Binary file not shown.
BIN
thesis/figs/ge_eu152_spec_org.pdf
Normal file
BIN
thesis/figs/ge_eu152_spec_org.pdf
Normal file
Binary file not shown.
BIN
thesis/figs/mucap_proton.pdf
Normal file
BIN
thesis/figs/mucap_proton.pdf
Normal file
Binary file not shown.
BIN
thesis/figs/mucap_quark.pdf
Normal file
BIN
thesis/figs/mucap_quark.pdf
Normal file
Binary file not shown.
BIN
thesis/figs/muon_event.pdf
Normal file
BIN
thesis/figs/muon_event.pdf
Normal file
Binary file not shown.
BIN
thesis/figs/nparticles_Al100_half.pdf
Normal file
BIN
thesis/figs/nparticles_Al100_half.pdf
Normal file
Binary file not shown.
|
Before Width: | Height: | Size: 110 KiB After Width: | Height: | Size: 110 KiB |
BIN
thesis/figs/pid_sim.pdf
Normal file
BIN
thesis/figs/pid_sim.pdf
Normal file
Binary file not shown.
BIN
thesis/figs/si16_xray.pdf
Normal file
BIN
thesis/figs/si16_xray.pdf
Normal file
Binary file not shown.
BIN
thesis/figs/si16p_allparticle_lifetime.pdf
Normal file
BIN
thesis/figs/si16p_allparticle_lifetime.pdf
Normal file
Binary file not shown.
BIN
thesis/figs/si16p_dedx.pdf
Normal file
BIN
thesis/figs/si16p_dedx.pdf
Normal file
Binary file not shown.
BIN
thesis/figs/si16p_dedx_cut.pdf
Normal file
BIN
thesis/figs/si16p_dedx_cut.pdf
Normal file
Binary file not shown.
BIN
thesis/figs/si16p_dedx_log.pdf
Normal file
BIN
thesis/figs/si16p_dedx_log.pdf
Normal file
Binary file not shown.
BIN
thesis/figs/si16p_dedx_loge+logde.pdf
Normal file
BIN
thesis/figs/si16p_dedx_loge+logde.pdf
Normal file
Binary file not shown.
BIN
thesis/figs/si16p_dedx_nocut_log.pdf
Normal file
BIN
thesis/figs/si16p_dedx_nocut_log.pdf
Normal file
Binary file not shown.
BIN
thesis/figs/si16p_dedx_proton_select.pdf
Normal file
BIN
thesis/figs/si16p_dedx_proton_select.pdf
Normal file
Binary file not shown.
BIN
thesis/figs/si16p_loge+logde.pdf
Normal file
BIN
thesis/figs/si16p_loge+logde.pdf
Normal file
Binary file not shown.
BIN
thesis/figs/si16p_proton_after_ecut.pdf
Normal file
BIN
thesis/figs/si16p_proton_after_ecut.pdf
Normal file
Binary file not shown.
BIN
thesis/figs/si16p_proton_ecut_500nstcut.pdf
Normal file
BIN
thesis/figs/si16p_proton_ecut_500nstcut.pdf
Normal file
Binary file not shown.
BIN
thesis/figs/si16p_proton_lifetime copy.pdf
Normal file
BIN
thesis/figs/si16p_proton_lifetime copy.pdf
Normal file
Binary file not shown.
BIN
thesis/figs/si16p_proton_lifetime.pdf
Normal file
BIN
thesis/figs/si16p_proton_lifetime.pdf
Normal file
Binary file not shown.
BIN
thesis/figs/si16p_toyMC.pdf
Normal file
BIN
thesis/figs/si16p_toyMC.pdf
Normal file
Binary file not shown.
BIN
thesis/figs/si16p_xray.pdf
Normal file
BIN
thesis/figs/si16p_xray.pdf
Normal file
Binary file not shown.
BIN
thesis/figs/sir2_bias_alpha.pdf
Normal file
BIN
thesis/figs/sir2_bias_alpha.pdf
Normal file
Binary file not shown.
BIN
thesis/figs/sir2_edep.pdf
Normal file
BIN
thesis/figs/sir2_edep.pdf
Normal file
Binary file not shown.
BIN
thesis/figs/sir2_edep_components.pdf
Normal file
BIN
thesis/figs/sir2_edep_components.pdf
Normal file
Binary file not shown.
BIN
thesis/figs/sir2_edep_mc.pdf
Normal file
BIN
thesis/figs/sir2_edep_mc.pdf
Normal file
Binary file not shown.
BIN
thesis/figs/sir2_ges_self_tdiff.pdf
Normal file
BIN
thesis/figs/sir2_ges_self_tdiff.pdf
Normal file
Binary file not shown.
BIN
thesis/figs/sir2_ges_self_tdiff.png
Normal file
BIN
thesis/figs/sir2_ges_self_tdiff.png
Normal file
Binary file not shown.
|
After Width: | Height: | Size: 237 KiB |
BIN
thesis/figs/sir2_mc_pdfs.pdf
Normal file
BIN
thesis/figs/sir2_mc_pdfs.pdf
Normal file
Binary file not shown.
BIN
thesis/figs/sir2_meas_spec.pdf
Normal file
BIN
thesis/figs/sir2_meas_spec.pdf
Normal file
Binary file not shown.
BIN
thesis/figs/sir2_mllfit.pdf
Normal file
BIN
thesis/figs/sir2_mllfit.pdf
Normal file
Binary file not shown.
BIN
thesis/figs/sir2_mllfit_contour.pdf
Normal file
BIN
thesis/figs/sir2_mllfit_contour.pdf
Normal file
Binary file not shown.
BIN
thesis/figs/sir2_mllfit_nbkg.pdf
Normal file
BIN
thesis/figs/sir2_mllfit_nbkg.pdf
Normal file
Binary file not shown.
BIN
thesis/figs/sir2_mllfit_nebeam.pdf
Normal file
BIN
thesis/figs/sir2_mllfit_nebeam.pdf
Normal file
Binary file not shown.
BIN
thesis/figs/sir2_nchargedparticles.pdf
Normal file
BIN
thesis/figs/sir2_nchargedparticles.pdf
Normal file
Binary file not shown.
BIN
thesis/figs/sir2_sir2f_amp_1us_slices.pdf
Normal file
BIN
thesis/figs/sir2_sir2f_amp_1us_slices.pdf
Normal file
Binary file not shown.
BIN
thesis/figs/sir2_xray.pdf
Normal file
BIN
thesis/figs/sir2_xray.pdf
Normal file
Binary file not shown.
BIN
thesis/figs/sir2_xray_2.pdf
Normal file
BIN
thesis/figs/sir2_xray_2.pdf
Normal file
Binary file not shown.
BIN
thesis/figs/sir2_xray_22.pdf
Normal file
BIN
thesis/figs/sir2_xray_22.pdf
Normal file
Binary file not shown.
BIN
thesis/figs/sobottka_spec.pdf
Normal file
BIN
thesis/figs/sobottka_spec.pdf
Normal file
Binary file not shown.
BIN
thesis/figs/sobottka_spec2.pdf
Normal file
BIN
thesis/figs/sobottka_spec2.pdf
Normal file
Binary file not shown.
BIN
thesis/figs/tap_maxbin_bad.pdf
Normal file
BIN
thesis/figs/tap_maxbin_bad.pdf
Normal file
Binary file not shown.
BIN
thesis/figs/tap_maxbin_bad2.pdf
Normal file
BIN
thesis/figs/tap_maxbin_bad2.pdf
Normal file
Binary file not shown.
BIN
thesis/figs/toyMC_alpha.pdf
Normal file
BIN
thesis/figs/toyMC_alpha.pdf
Normal file
Binary file not shown.
@@ -12,10 +12,11 @@ inner=1.25in, outer=1in, twoside]{geometry}
|
|||||||
|
|
||||||
%$ Hyper-link ..
|
%$ Hyper-link ..
|
||||||
\RequirePackage[%
|
\RequirePackage[%
|
||||||
colorlinks=true,% color links instead of using boxes
|
%colorlinks=false,% color links instead of using boxes
|
||||||
linkcolor=red,% color for internal (intra-document) links
|
%linkcolor=red,% color for internal (intra-document) links
|
||||||
citecolor=green,% color for bibliographic links
|
%citecolor=green,% color for bibliographic links
|
||||||
urlcolor=blue,% color for URL links
|
%urlcolor=blue,% color for URL links
|
||||||
|
hidelinks,
|
||||||
hyperfootnotes=false,% disable links to footnotes (because feature broken)
|
hyperfootnotes=false,% disable links to footnotes (because feature broken)
|
||||||
hyperindex,% make page numbers in index into hyperlinks
|
hyperindex,% make page numbers in index into hyperlinks
|
||||||
pdfstartview={FitH},% startup page view: fit width of page to window
|
pdfstartview={FitH},% startup page view: fit width of page to window
|
||||||
@@ -36,6 +37,9 @@ bookmarks
|
|||||||
\RequirePackage{emptypage}
|
\RequirePackage{emptypage}
|
||||||
%% Others
|
%% Others
|
||||||
\RequirePackage{booktabs}
|
\RequirePackage{booktabs}
|
||||||
|
\RequirePackage{caption}
|
||||||
|
\RequirePackage{pgfplotstable}
|
||||||
|
|
||||||
\RequirePackage{cite}
|
\RequirePackage{cite}
|
||||||
%\RequirePackage{morefloats}
|
%\RequirePackage{morefloats}
|
||||||
\RequirePackage{mathrsfs} % script font
|
\RequirePackage{mathrsfs} % script font
|
||||||
@@ -51,12 +55,14 @@ bookmarks
|
|||||||
\RequirePackage{setspace}
|
\RequirePackage{setspace}
|
||||||
\RequirePackage{verbatim}
|
\RequirePackage{verbatim}
|
||||||
\RequirePackage{lipsum}
|
\RequirePackage{lipsum}
|
||||||
\RequirePackage{datatool}
|
|
||||||
\RequirePackage[capitalise]{cleveref}
|
|
||||||
\RequirePackage[final]{listings}
|
\RequirePackage[final]{listings}
|
||||||
\RequirePackage{xfrac}
|
\RequirePackage{xfrac}
|
||||||
%% Units
|
%% Units
|
||||||
\RequirePackage[]{siunitx}
|
%\RequirePackage[]{siunitx}
|
||||||
|
\RequirePackage[detect-weight=true, detect-family=true]{siunitx}
|
||||||
|
\RequirePackage{hepnames}
|
||||||
|
\RequirePackage{array}
|
||||||
%% Various fonts ...
|
%% Various fonts ...
|
||||||
%\RequirePackage[T1]{fontenc}
|
%\RequirePackage[T1]{fontenc}
|
||||||
%\RequirePackage{charter}
|
%\RequirePackage{charter}
|
||||||
@@ -76,6 +82,8 @@ bookmarks
|
|||||||
%\linespread{1.025} % Palatino leads a little more leading
|
%\linespread{1.025} % Palatino leads a little more leading
|
||||||
%\usepackage[small]{eulervm}
|
%\usepackage[small]{eulervm}
|
||||||
|
|
||||||
|
|
||||||
|
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
|
||||||
\RequirePackage{tabularx}
|
\RequirePackage{tabularx}
|
||||||
\RequirePackage{color}
|
\RequirePackage{color}
|
||||||
\RequirePackage{pifont}
|
\RequirePackage{pifont}
|
||||||
@@ -188,6 +196,26 @@ bookmarks
|
|||||||
\ignorespacesafterend%
|
\ignorespacesafterend%
|
||||||
}
|
}
|
||||||
|
|
||||||
|
\newenvironment{acknowledgements}{%
|
||||||
|
\cleardoublepage%
|
||||||
|
\adjustwidth{\@declarationextramargin}{\@declarationextramargin}%
|
||||||
|
\vspace*{\@frontmattertopskip}%
|
||||||
|
\begin{center}%
|
||||||
|
\begingroup
|
||||||
|
\ifx\@sftitles\@empty\else\sf\fi
|
||||||
|
{\LARGE\textbf{Acknowledgements}}%
|
||||||
|
\endgroup
|
||||||
|
\end{center}%
|
||||||
|
\vspace*{1cm}%
|
||||||
|
}{%
|
||||||
|
%\newline \newline \newline%
|
||||||
|
%\begin{flushright}
|
||||||
|
% \thesisauthor\newline
|
||||||
|
% \today\newline
|
||||||
|
%\end{flushright}
|
||||||
|
\endadjustwidth%
|
||||||
|
\ignorespacesafterend%
|
||||||
|
}
|
||||||
%% Change the spacing of lines
|
%% Change the spacing of lines
|
||||||
\DeclareRobustCommand{\setspacing}[1]{%
|
\DeclareRobustCommand{\setspacing}[1]{%
|
||||||
\setfrontmatterspacing{#1}%
|
\setfrontmatterspacing{#1}%
|
||||||
@@ -270,3 +298,6 @@ bookmarks
|
|||||||
\endgroup%
|
\endgroup%
|
||||||
}
|
}
|
||||||
\renewcommand{\maketitle}[1]{\titlepage{}}
|
\renewcommand{\maketitle}[1]{\titlepage{}}
|
||||||
|
|
||||||
|
%% Cleveref should be the last package to not be messed up by others
|
||||||
|
\RequirePackage[noabbrev]{cleveref}
|
||||||
|
|||||||
@@ -112,6 +112,41 @@
|
|||||||
Timestamp = {2014-04-09}
|
Timestamp = {2014-04-09}
|
||||||
}
|
}
|
||||||
|
|
||||||
|
@Article{Agostinelli.etal.2003,
|
||||||
|
Title = {{GEANT4: A Simulation toolkit}},
|
||||||
|
Author = {Agostinelli, S. and others},
|
||||||
|
Journal = {Nucl. Instrum. Meth.},
|
||||||
|
Year = {2003},
|
||||||
|
Pages = {250-303},
|
||||||
|
Volume = {A506},
|
||||||
|
|
||||||
|
Collaboration = {GEANT4},
|
||||||
|
Doi = {10.1016/S0168-9002(03)01368-8},
|
||||||
|
Owner = {NT},
|
||||||
|
Reportnumber = {SLAC-PUB-9350, FERMILAB-PUB-03-339},
|
||||||
|
Slaccitation = {%%CITATION = NUIMA,A506,250;%%},
|
||||||
|
Timestamp = {2014-10-11}
|
||||||
|
}
|
||||||
|
|
||||||
|
@Article{AhmadAzuelos.etal.1988a,
|
||||||
|
Title = {Search for muon-electron and muon-positron conversion},
|
||||||
|
Author = {Ahmad, S. and Azuelos, G. and Blecher, M. and Bryman, D. and Burnham, R. and Clifford, E. and Depommier, P. and Dixit, M. and Gotow, K. and Hargrove, C. and Hasinoff, M. and Leitch, M. and Macdonald, J. and Mes, H. and Navon, I. and Numao, T. and Poutissou, J-M. and Poutissou, R. and Schlatter, P. and Spuller, J. and Summhammer, J.},
|
||||||
|
Journal = {Phys. Rev. D},
|
||||||
|
Year = {1988},
|
||||||
|
|
||||||
|
Month = {Oct},
|
||||||
|
Pages = {2102--2120},
|
||||||
|
Volume = {38},
|
||||||
|
|
||||||
|
Doi = {10.1103/PhysRevD.38.2102},
|
||||||
|
Issue = {7},
|
||||||
|
Numpages = {19},
|
||||||
|
Owner = {NT},
|
||||||
|
Publisher = {American Physical Society},
|
||||||
|
Timestamp = {2014-12-10},
|
||||||
|
Url = {http://link.aps.org/doi/10.1103/PhysRevD.38.2102}
|
||||||
|
}
|
||||||
|
|
||||||
@Article{AhmadAzuelos.etal.1988,
|
@Article{AhmadAzuelos.etal.1988,
|
||||||
Title = {Search for muon-electron and muon-positron conversion},
|
Title = {Search for muon-electron and muon-positron conversion},
|
||||||
Author = {Ahmad, S and Azuelos, G and Blecher, M and Bryman, DA and Burnham, RA and Clifford, ETH and Depommier, P and Dixit, MS and Gotow, K and Hargrove, CK and others},
|
Author = {Ahmad, S and Azuelos, G and Blecher, M and Bryman, DA and Burnham, RA and Clifford, ETH and Depommier, P and Dixit, MS and Gotow, K and Hargrove, CK and others},
|
||||||
@@ -131,7 +166,7 @@
|
|||||||
@Article{AhmadAzuelos.etal.1987,
|
@Article{AhmadAzuelos.etal.1987,
|
||||||
Title = {Searches for muon-electron and muon-positron conversion in titanium},
|
Title = {Searches for muon-electron and muon-positron conversion in titanium},
|
||||||
Author = {Ahmad, S and Azuelos, G and Blecher, M and Bryman, D and Burnham, RA and Clifford, ETH and Depommier, P and Dixit, MS and Gotow, K and Hargrove, CK and others},
|
Author = {Ahmad, S and Azuelos, G and Blecher, M and Bryman, D and Burnham, RA and Clifford, ETH and Depommier, P and Dixit, MS and Gotow, K and Hargrove, CK and others},
|
||||||
Journal = {Physical review letters},
|
Journal = {Phys. Rev. Lett.},
|
||||||
Year = {1987},
|
Year = {1987},
|
||||||
Number = {9},
|
Number = {9},
|
||||||
Pages = {970},
|
Pages = {970},
|
||||||
@@ -145,11 +180,11 @@
|
|||||||
}
|
}
|
||||||
|
|
||||||
@TechReport{COMET.2012,
|
@TechReport{COMET.2012,
|
||||||
Title = {Experimental Proposal for Phase-I of the COMET
|
Title = {Experimental Proposal for Phase-I of the COMET Experiment at J-PARC},
|
||||||
Experiment at J-PARC},
|
|
||||||
Author = {R. Akhmetshin and A. Bondar and L. Epshteyn and
|
Author = {R. Akhmetshin and A. Bondar and L. Epshteyn and
|
||||||
G. Fedotovich and D. Grigoriev and V. Kazanin and A. Ryzhenenkov and
|
G. Fedotovich and D. Grigoriev and V. Kazanin and A. Ryzhenenkov and
|
||||||
D. Shemyakin and Yu. Yudin and others},
|
D. Shemyakin and Yu. Yudin and others},
|
||||||
|
Institution = {KEK},
|
||||||
Year = {2012},
|
Year = {2012},
|
||||||
Month = {7},
|
Month = {7},
|
||||||
Number = {KEK/J-PARC-PAC 2012-10},
|
Number = {KEK/J-PARC-PAC 2012-10},
|
||||||
@@ -273,7 +308,7 @@
|
|||||||
@Article{AndreevBanks.etal.2013a,
|
@Article{AndreevBanks.etal.2013a,
|
||||||
Title = {Measurement of Muon Capture on the Proton to 1\% Precision and Determination of the Pseudoscalar Coupling g P},
|
Title = {Measurement of Muon Capture on the Proton to 1\% Precision and Determination of the Pseudoscalar Coupling g P},
|
||||||
Author = {Andreev, VA and Banks, TI and Carey, RM and Case, TA and Clayton, SM and Crowe, KM and Deutsch, J and Egger, J and Freedman, SJ and Ganzha, VA and others},
|
Author = {Andreev, VA and Banks, TI and Carey, RM and Case, TA and Clayton, SM and Crowe, KM and Deutsch, J and Egger, J and Freedman, SJ and Ganzha, VA and others},
|
||||||
Journal = {Physical review letters},
|
Journal = {Phys. Rev. Lett.},
|
||||||
Year = {2013},
|
Year = {2013},
|
||||||
Number = {1},
|
Number = {1},
|
||||||
Pages = {012504},
|
Pages = {012504},
|
||||||
@@ -307,10 +342,28 @@
|
|||||||
Timestamp = {2014-05-02}
|
Timestamp = {2014-05-02}
|
||||||
}
|
}
|
||||||
|
|
||||||
|
@Article{AudiWapstra.etal.2003,
|
||||||
|
Title = {The Ame2003 atomic mass evaluation: (II). Tables, graphs and references },
|
||||||
|
Author = {G. Audi and A.H. Wapstra and C. Thibault},
|
||||||
|
Journal = {Nucl. Phys. A},
|
||||||
|
Year = {2003},
|
||||||
|
Note = {The 2003 \{NUBASE\} and Atomic Mass Evaluations },
|
||||||
|
Number = {1},
|
||||||
|
Pages = {337 - 676},
|
||||||
|
Volume = {729},
|
||||||
|
|
||||||
|
Doi = {http://dx.doi.org/10.1016/j.nuclphysa.2003.11.003},
|
||||||
|
File = {Published version:AudiWapstra.etal.2003.pdf:PDF},
|
||||||
|
ISSN = {0375-9474},
|
||||||
|
Owner = {NT},
|
||||||
|
Timestamp = {2014-10-26},
|
||||||
|
Url = {http://www.sciencedirect.com/science/article/pii/S0375947403018098}
|
||||||
|
}
|
||||||
|
|
||||||
@Article{BadertscherBorer.etal.1982,
|
@Article{BadertscherBorer.etal.1982,
|
||||||
Title = {A search for muon-electron and muon-positron conversion in sulfur},
|
Title = {A search for muon-electron and muon-positron conversion in sulfur},
|
||||||
Author = {Badertscher, A and Borer, K and Czapek, G and Fl{\"u}ckiger, A and H{\"a}nni, H and Hahn, B and Hugentobler, E and Markees, A and Marti, T and Moser, U and others},
|
Author = {Badertscher, A and Borer, K and Czapek, G and Fl{\"u}ckiger, A and H{\"a}nni, H and Hahn, B and Hugentobler, E and Markees, A and Marti, T and Moser, U and others},
|
||||||
Journal = {Nuclear Physics A},
|
Journal = {Nucl. Phys. A},
|
||||||
Year = {1982},
|
Year = {1982},
|
||||||
Number = {2},
|
Number = {2},
|
||||||
Pages = {406--440},
|
Pages = {406--440},
|
||||||
@@ -323,6 +376,42 @@
|
|||||||
Timestamp = {2014-04-24}
|
Timestamp = {2014-04-24}
|
||||||
}
|
}
|
||||||
|
|
||||||
|
@Article{BadertscherBorer.etal.1982a,
|
||||||
|
Title = {A search for muon-electron and muon-positron conversion in sulfur },
|
||||||
|
Author = {A. Badertscher and K. Borer and G. Czapek and B. Hahn and E. Hugentobler and A. Markees and T. Marti and U. Moser and E. Ramseyer and J. Schacher and H. Scheidiger and P. Schlatter and G. Viertel and W. Zeller},
|
||||||
|
Journal = {Nuclear Physics A },
|
||||||
|
Year = {1982},
|
||||||
|
Number = {2<EFBFBD>3},
|
||||||
|
Pages = {406 - 440},
|
||||||
|
Volume = {377},
|
||||||
|
|
||||||
|
Doi = {http://dx.doi.org/10.1016/0375-9474(82)90049-5},
|
||||||
|
ISSN = {0375-9474},
|
||||||
|
Keywords = {Nuclear reactions },
|
||||||
|
Owner = {NT},
|
||||||
|
Timestamp = {2014-12-10},
|
||||||
|
Url = {http://www.sciencedirect.com/science/article/pii/0375947482900495}
|
||||||
|
}
|
||||||
|
|
||||||
|
@Article{BadertscherBorer.etal.1977,
|
||||||
|
Title = {Upper Limit for Muon-Electron Conversion in Sulfur},
|
||||||
|
Author = {Badertscher, A. and Borer, K. and Czapek, H. and Hahn, B. and Hugentobler, E. and Markees, A. and Moser, U. and Redwine, R. and Schacher, J. and Scheidiger, H. and Schlatter, P. and Viertel, G.},
|
||||||
|
Journal = {Phys. Rev. Lett.},
|
||||||
|
Year = {1977},
|
||||||
|
|
||||||
|
Month = {Nov},
|
||||||
|
Pages = {1385--1387},
|
||||||
|
Volume = {39},
|
||||||
|
|
||||||
|
Doi = {10.1103/PhysRevLett.39.1385},
|
||||||
|
Issue = {22},
|
||||||
|
Numpages = {3},
|
||||||
|
Owner = {NT},
|
||||||
|
Publisher = {American Physical Society},
|
||||||
|
Timestamp = {2014-12-10},
|
||||||
|
Url = {http://link.aps.org/doi/10.1103/PhysRevLett.39.1385}
|
||||||
|
}
|
||||||
|
|
||||||
@Article{BalandinGrebenyuk.etal.1978,
|
@Article{BalandinGrebenyuk.etal.1978,
|
||||||
Title = {{Energy Spectra and Asymmetry of Charged Particles from
|
Title = {{Energy Spectra and Asymmetry of Charged Particles from
|
||||||
Negative Muon Capture by Nuclei}},
|
Negative Muon Capture by Nuclei}},
|
||||||
@@ -352,6 +441,22 @@
|
|||||||
Timestamp = {2014.02.10}
|
Timestamp = {2014.02.10}
|
||||||
}
|
}
|
||||||
|
|
||||||
|
@Article{BartleyDavies.etal.1964,
|
||||||
|
Title = {A search for neutrinoless decay modes of the negative muon },
|
||||||
|
Author = {J.H. Bartley and H. Davies and H. Muirhead and T. Woodhead},
|
||||||
|
Journal = {Physics Letters },
|
||||||
|
Year = {1964},
|
||||||
|
Number = {3},
|
||||||
|
Pages = {258 - 259},
|
||||||
|
Volume = {13},
|
||||||
|
|
||||||
|
Doi = {http://dx.doi.org/10.1016/0031-9163(64)90479-2},
|
||||||
|
ISSN = {0031-9163},
|
||||||
|
Owner = {NT},
|
||||||
|
Timestamp = {2014-12-10},
|
||||||
|
Url = {http://www.sciencedirect.com/science/article/pii/0031916364904792}
|
||||||
|
}
|
||||||
|
|
||||||
@Article{BauerBortels.1990,
|
@Article{BauerBortels.1990,
|
||||||
Title = {Response of Si detectors to electrons, deuterons and alpha particles},
|
Title = {Response of Si detectors to electrons, deuterons and alpha particles},
|
||||||
Author = {Bauer, P and Bortels, G},
|
Author = {Bauer, P and Bortels, G},
|
||||||
@@ -462,6 +567,22 @@
|
|||||||
Timestamp = {2014-04-08}
|
Timestamp = {2014-04-08}
|
||||||
}
|
}
|
||||||
|
|
||||||
|
@Article{Bichsel.2006,
|
||||||
|
Title = {A method to improve tracking and particle identification in TPCs and silicon detectors},
|
||||||
|
Author = {Bichsel, Hans},
|
||||||
|
Journal = {Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment},
|
||||||
|
Year = {2006},
|
||||||
|
Number = {1},
|
||||||
|
Pages = {154--197},
|
||||||
|
Volume = {562},
|
||||||
|
|
||||||
|
Doi = {10.1016/j.nima.2006.03.009},
|
||||||
|
File = {Published version:Bichsel.2006.pdf:PDF},
|
||||||
|
Owner = {NT},
|
||||||
|
Publisher = {Elsevier},
|
||||||
|
Timestamp = {2014-09-16}
|
||||||
|
}
|
||||||
|
|
||||||
@Article{Bichsel.1988,
|
@Article{Bichsel.1988,
|
||||||
Title = {{Straggling in Thin Silicon Detectors}},
|
Title = {{Straggling in Thin Silicon Detectors}},
|
||||||
Author = {Bichsel, H.},
|
Author = {Bichsel, H.},
|
||||||
@@ -536,6 +657,45 @@
|
|||||||
Timestamp = {2014-04-09}
|
Timestamp = {2014-04-09}
|
||||||
}
|
}
|
||||||
|
|
||||||
|
@Article{Bryman1985,
|
||||||
|
Title = {Search for \textit{$\mu${}} - \textit{e} conversion in Ti},
|
||||||
|
Author = {Bryman, D. A. and Clifford, E. T. H. and Leitch, M. J. and Navon, I. and Numao, T. and Schlatter, P. and Dixit, M. S. and Hargrove, C. K. and Mes, H. and Burnham, R. A. and Hasinoff, M. and Poutissou, J.-M. and Macdonald, J. A. and Spuller, J. and Azuelos, G. and Depommier, P. and Martin, J.-P. and Poutissou, R. and Blecher, M. and Gotow, K. and Carter, A. L. and Anderson, H. L. and Wright, S. C.},
|
||||||
|
Journal = {Phys. Rev. Lett.},
|
||||||
|
Year = {1985},
|
||||||
|
|
||||||
|
Month = {Jul},
|
||||||
|
Pages = {465--468},
|
||||||
|
Volume = {55},
|
||||||
|
|
||||||
|
__markedentry = {[nam:6]},
|
||||||
|
Doi = {10.1103/PhysRevLett.55.465},
|
||||||
|
Issue = {5},
|
||||||
|
Numpages = {0},
|
||||||
|
Owner = {nam},
|
||||||
|
Publisher = {American Physical Society},
|
||||||
|
Timestamp = {2015.04.27},
|
||||||
|
Url = {http://link.aps.org/doi/10.1103/PhysRevLett.55.465}
|
||||||
|
}
|
||||||
|
|
||||||
|
@Article{BrymanBlecher.etal.1972,
|
||||||
|
Title = {Search for the Reaction },
|
||||||
|
Author = {Bryman, D. and Blecher, M. and Gotow, K. and Powers, R.},
|
||||||
|
Journal = {Phys. Rev. Lett.},
|
||||||
|
Year = {1972},
|
||||||
|
|
||||||
|
Month = {May},
|
||||||
|
Pages = {1469--1471},
|
||||||
|
Volume = {28},
|
||||||
|
|
||||||
|
Doi = {10.1103/PhysRevLett.28.1469},
|
||||||
|
Issue = {22},
|
||||||
|
Numpages = {3},
|
||||||
|
Owner = {NT},
|
||||||
|
Publisher = {American Physical Society},
|
||||||
|
Timestamp = {2014-12-10},
|
||||||
|
Url = {http://link.aps.org/doi/10.1103/PhysRevLett.28.1469}
|
||||||
|
}
|
||||||
|
|
||||||
@TechReport{COMET.2007,
|
@TechReport{COMET.2007,
|
||||||
Title = {An Experimental Search for Lepton Flavor Violating $\mu^--e^-$ Conversion at Sensitivity of $10^{-16}$ with a Slow-Extracted Bunched Proton Beam},
|
Title = {An Experimental Search for Lepton Flavor Violating $\mu^--e^-$ Conversion at Sensitivity of $10^{-16}$ with a Slow-Extracted Bunched Proton Beam},
|
||||||
Author = {D. Bryman and R. Palmer and Y. Iwashita and M.
|
Author = {D. Bryman and R. Palmer and Y. Iwashita and M.
|
||||||
@@ -608,16 +768,49 @@
|
|||||||
Timestamp = {2014-04-03}
|
Timestamp = {2014-04-03}
|
||||||
}
|
}
|
||||||
|
|
||||||
@Article{COMET.2009,
|
@Article{CiriglianoKitano.etal.2009,
|
||||||
Title = {Conceptual design report for experimental search for lepton flavor violating $\mu$-- e- conversion at sensitivity of 10^{-16} with a slow-extracted bunched proton beam},
|
Title = {Model discriminating power of $\mu\rightarrow e$ conversion in nuclei},
|
||||||
Author = {COMET},
|
Author = {Cirigliano, Vincenzo and Kitano, Ryuichiro and Okada, Yasuhiro and Tuzon, Paula},
|
||||||
Journal = {KEK Report},
|
Journal = {Phys. Rev. D},
|
||||||
Year = {2009},
|
Year = {2009},
|
||||||
Pages = {2009},
|
|
||||||
Volume = {10},
|
Month = {Jul},
|
||||||
|
Pages = {013002},
|
||||||
|
Volume = {80},
|
||||||
|
|
||||||
|
Doi = {10.1103/PhysRevD.80.013002},
|
||||||
|
File = {Published version:CiriglianoKitano.etal.2009.pdf:PDF},
|
||||||
|
Issue = {1},
|
||||||
|
Numpages = {13},
|
||||||
|
Owner = {NT},
|
||||||
|
Publisher = {American Physical Society},
|
||||||
|
Timestamp = {2014-10-29},
|
||||||
|
Url = {http://link.aps.org/doi/10.1103/PhysRevD.80.013002}
|
||||||
|
}
|
||||||
|
|
||||||
|
@TechReport{COMET.2014,
|
||||||
|
Title = {COMET Phase-I Technical Design Report},
|
||||||
|
Author = {COMET},
|
||||||
|
Institution = {KEK},
|
||||||
|
Year = {2014},
|
||||||
|
Month = {9},
|
||||||
|
Type = {Report},
|
||||||
|
|
||||||
Owner = {NT},
|
Owner = {NT},
|
||||||
Timestamp = {2014-07-13}
|
Timestamp = {2014-10-29}
|
||||||
|
}
|
||||||
|
|
||||||
|
@TechReport{COMET.2009,
|
||||||
|
Title = {Conceptual Design Report for experimental search for lepton flavor violating $\mu^- - e^-$ conversion at sensitivity of $10^{-16}$ with a slow-extracted bunched proton beam},
|
||||||
|
Author = {COMET},
|
||||||
|
Institution = {KEK},
|
||||||
|
Year = {2009},
|
||||||
|
Type = {Report},
|
||||||
|
|
||||||
|
Owner = {NT},
|
||||||
|
Pages = {2009},
|
||||||
|
Timestamp = {2014-07-13},
|
||||||
|
Volume = {10}
|
||||||
}
|
}
|
||||||
|
|
||||||
@Article{ConfortoConversi.etal.1962,
|
@Article{ConfortoConversi.etal.1962,
|
||||||
@@ -818,6 +1011,22 @@
|
|||||||
Url = {http://indico.cern.ch/event/107747/session/1/contribution/71/material/paper/0.pdf}
|
Url = {http://indico.cern.ch/event/107747/session/1/contribution/71/material/paper/0.pdf}
|
||||||
}
|
}
|
||||||
|
|
||||||
|
@Article{DohmenGroth.etal.1993,
|
||||||
|
Title = {Test of lepton-flavour conservation in mu-e conversion on titanium },
|
||||||
|
Author = {C. Dohmen and K.-D. Groth and B. Heer and W. Honecker and G. Otter and B. Steinr<6E>cken and P. Wintz and V. Djordjadze and J. Hofmann and T. Kozlowski and S. Playfer and W. Bertl and J. Egger and W. Herold and B. Krause and H.K. Walter and R. Engfer and Ch. Findeisen and M. Grossmann-Handschin and E.A. Hermes and F. Muheim and C.B. Niebuhr and H.S. Pruys and L. Ricken and D. Vermeulen and A. van der Schaaf},
|
||||||
|
Journal = {Physics Letters B },
|
||||||
|
Year = {1993},
|
||||||
|
Number = {4},
|
||||||
|
Pages = {631 - 636},
|
||||||
|
Volume = {317},
|
||||||
|
|
||||||
|
Doi = {http://dx.doi.org/10.1016/0370-2693(93)91383-X},
|
||||||
|
ISSN = {0370-2693},
|
||||||
|
Owner = {NT},
|
||||||
|
Timestamp = {2014-12-10},
|
||||||
|
Url = {http://www.sciencedirect.com/science/article/pii/037026939391383X}
|
||||||
|
}
|
||||||
|
|
||||||
@Article{EcksteinPratt.1959,
|
@Article{EcksteinPratt.1959,
|
||||||
Title = {Radiative muon decay },
|
Title = {Radiative muon decay },
|
||||||
Author = {S.G Eckstein and R.H Pratt},
|
Author = {S.G Eckstein and R.H Pratt},
|
||||||
@@ -1049,7 +1258,6 @@
|
|||||||
Pages = {741--757},
|
Pages = {741--757},
|
||||||
Volume = {36},
|
Volume = {36},
|
||||||
|
|
||||||
__markedentry = {[NT:]},
|
|
||||||
Doi = {10.1103/PhysRevC.36.741},
|
Doi = {10.1103/PhysRevC.36.741},
|
||||||
File = {Published version:GadioliGadioli.1987.pdf:PDF},
|
File = {Published version:GadioliGadioli.1987.pdf:PDF},
|
||||||
Issue = {2},
|
Issue = {2},
|
||||||
@@ -1150,7 +1358,7 @@
|
|||||||
@Article{Henley.1952,
|
@Article{Henley.1952,
|
||||||
Title = {$\pi$-Meson Production by Protons on Nuclei},
|
Title = {$\pi$-Meson Production by Protons on Nuclei},
|
||||||
Author = {Henley, Ernest M},
|
Author = {Henley, Ernest M},
|
||||||
Journal = {Physical Review},
|
Journal = {Phys. Rev.},
|
||||||
Year = {1952},
|
Year = {1952},
|
||||||
Number = {2},
|
Number = {2},
|
||||||
Pages = {204},
|
Pages = {204},
|
||||||
@@ -1197,10 +1405,30 @@
|
|||||||
Timestamp = {2014-04-09}
|
Timestamp = {2014-04-09}
|
||||||
}
|
}
|
||||||
|
|
||||||
|
@Article{HoneckerDohmen.etal.1996,
|
||||||
|
Title = {Improved Limit on the Branching Ratio of $$\mu${}$\rightarrow${}\mathit{e}$ Conversion on Lead},
|
||||||
|
Author = {Honecker, W. and Dohmen, C. and Haan, H. and Junker, D. and Otter, G. and Starlinger, M. and Wintz, P. and Hofmann, J. and Bertl, W. and Egger, J. and Krause, B. and Eggli, S. and Engfer, R. and Findeisen, Ch. and Hermes, E. and Kozlowski, T. and Niebuhr, C. and Pruys, H. and van der Schaaf, A.},
|
||||||
|
Journal = {Phys. Rev. Lett.},
|
||||||
|
Year = {1996},
|
||||||
|
|
||||||
|
Month = {Jan},
|
||||||
|
Pages = {200--203},
|
||||||
|
Volume = {76},
|
||||||
|
|
||||||
|
Collaboration = {(SINDRUM II Collaboration)},
|
||||||
|
Doi = {10.1103/PhysRevLett.76.200},
|
||||||
|
Issue = {2},
|
||||||
|
Numpages = {4},
|
||||||
|
Owner = {NT},
|
||||||
|
Publisher = {American Physical Society},
|
||||||
|
Timestamp = {2014-12-10},
|
||||||
|
Url = {http://link.aps.org/doi/10.1103/PhysRevLett.76.200}
|
||||||
|
}
|
||||||
|
|
||||||
@Article{Huff.1961,
|
@Article{Huff.1961,
|
||||||
Title = {Decay rate of bound muons },
|
Title = {Decay rate of bound muons },
|
||||||
Author = {Robert W Huff},
|
Author = {Robert W Huff},
|
||||||
Journal = {Annals of Physics },
|
Journal = {Annals of Physics},
|
||||||
Year = {1961},
|
Year = {1961},
|
||||||
Number = {2},
|
Number = {2},
|
||||||
Pages = {288 - 317},
|
Pages = {288 - 317},
|
||||||
@@ -1251,6 +1479,24 @@
|
|||||||
Timestamp = {2014-04-01}
|
Timestamp = {2014-04-01}
|
||||||
}
|
}
|
||||||
|
|
||||||
|
@Article{IsaakEngfer.etal.1983,
|
||||||
|
Title = {{INCLUSIVE NEUTRON AND CHARGED PARTICLE SPECTRA FROM THE
|
||||||
|
ABSORPTION OF STOPPED NEGATIVE PIONS IN NICKEL ISOTOPES}},
|
||||||
|
Author = {Isaak, H.P. and Engfer, R. and Hartmann, R. and Hermes,
|
||||||
|
E.A. and Pruys, H.S. and others},
|
||||||
|
Journal = {Nucl. Phys.},
|
||||||
|
Year = {1983},
|
||||||
|
Pages = {385},
|
||||||
|
Volume = {A392},
|
||||||
|
|
||||||
|
Doi = {10.1016/0375-9474(83)90134-3},
|
||||||
|
File = {Published version:IsaakEngfer.etal.1983.pdf:PDF},
|
||||||
|
Owner = {NT},
|
||||||
|
Reportnumber = {SIN-PR-81-12},
|
||||||
|
Slaccitation = {%%CITATION = NUPHA,A392,385;%%},
|
||||||
|
Timestamp = {2014-10-16}
|
||||||
|
}
|
||||||
|
|
||||||
@Article{Ishii.1959,
|
@Article{Ishii.1959,
|
||||||
Title = {An Analysis of the Charged Particles Emitted Following Negative Muon Absorptions in Photographic Emulsions},
|
Title = {An Analysis of the Charged Particles Emitted Following Negative Muon Absorptions in Photographic Emulsions},
|
||||||
Author = {Ishii, Chikai},
|
Author = {Ishii, Chikai},
|
||||||
@@ -1465,7 +1711,7 @@
|
|||||||
@Article{KotelchuckTyler.1968,
|
@Article{KotelchuckTyler.1968,
|
||||||
Title = {Search for a Conserved-Vector-Current Mechanism in the Emission of Protons from $\mu$-Stars in Emulsion},
|
Title = {Search for a Conserved-Vector-Current Mechanism in the Emission of Protons from $\mu$-Stars in Emulsion},
|
||||||
Author = {Kotelchuck, D and Tyler, James V},
|
Author = {Kotelchuck, D and Tyler, James V},
|
||||||
Journal = {Physical Review},
|
Journal = {Phys. Rev.},
|
||||||
Year = {1968},
|
Year = {1968},
|
||||||
Number = {4},
|
Number = {4},
|
||||||
Pages = {1190},
|
Pages = {1190},
|
||||||
@@ -1478,6 +1724,50 @@
|
|||||||
Url = {http://prola.aps.org/abstract/PR/v165/i4/p1190_1}
|
Url = {http://prola.aps.org/abstract/PR/v165/i4/p1190_1}
|
||||||
}
|
}
|
||||||
|
|
||||||
|
@Article{KozlowskiZglinski.1978,
|
||||||
|
Title = {{The Nuclear Excitations and Particle Emission Following
|
||||||
|
Muon Capture}},
|
||||||
|
Author = {Kozlowski, T. and Zglinski, A.},
|
||||||
|
Journal = {Nucl.Phys.},
|
||||||
|
Year = {1978},
|
||||||
|
Pages = {368-380},
|
||||||
|
Volume = {A305},
|
||||||
|
|
||||||
|
Doi = {10.1016/0375-9474(78)90345-7},
|
||||||
|
File = {Published version:KozlowskiZglinski.1978.pdf:PDF},
|
||||||
|
Owner = {NT},
|
||||||
|
Slaccitation = {%%CITATION = NUPHA,A305,368;%%},
|
||||||
|
Timestamp = {2014-10-16}
|
||||||
|
}
|
||||||
|
|
||||||
|
@Article{KozlowskiZglinski.1974,
|
||||||
|
Title = {{Nuclear muon capture - a simple model}},
|
||||||
|
Author = {Kozlowski, T. and Zglinski, A.},
|
||||||
|
Journal = {Phys. Lett.},
|
||||||
|
Year = {1974},
|
||||||
|
Pages = {222-224},
|
||||||
|
Volume = {B50},
|
||||||
|
|
||||||
|
Doi = {10.1016/0370-2693(74)90543-7},
|
||||||
|
File = {Published version:KozlowskiZglinski.1974.pdf:PDF},
|
||||||
|
Owner = {NT},
|
||||||
|
Slaccitation = {%%CITATION = PHLTA,B50,222;%%},
|
||||||
|
Timestamp = {2014-10-16}
|
||||||
|
}
|
||||||
|
|
||||||
|
@Article{KozlowskiZglinski.1974b,
|
||||||
|
Title = {{Pre-equilibrium particle emission after the nuclear muon
|
||||||
|
capture}},
|
||||||
|
Author = {Kozlowski, T. and Zglinski, A.},
|
||||||
|
Journal = {Nukleonika},
|
||||||
|
Year = {1974},
|
||||||
|
Pages = {721-725},
|
||||||
|
Volume = {19},
|
||||||
|
Owner = {NT},
|
||||||
|
Slaccitation = {%%CITATION = NUKLA,19,721;%%},
|
||||||
|
Timestamp = {2014-10-16}
|
||||||
|
}
|
||||||
|
|
||||||
@Article{KraneSharma.etal.1979,
|
@Article{KraneSharma.etal.1979,
|
||||||
Title = {Energetic charged-particle spectrum following $\mu$-capture by nuclei},
|
Title = {Energetic charged-particle spectrum following $\mu$-capture by nuclei},
|
||||||
Author = {Krane, KS and Sharma, TC and Swenson, LW and McDaniels, DK and Varghese, P and Wood, BE and Silbar, RR and Wohlfahrt, HD and Goulding, CA},
|
Author = {Krane, KS and Sharma, TC and Swenson, LW and McDaniels, DK and Varghese, P and Wood, BE and Silbar, RR and Wohlfahrt, HD and Goulding, CA},
|
||||||
@@ -1771,6 +2061,25 @@
|
|||||||
Url = {http://www.sciencedirect.com/science/article/pii/S0168900207008790}
|
Url = {http://www.sciencedirect.com/science/article/pii/S0168900207008790}
|
||||||
}
|
}
|
||||||
|
|
||||||
|
@Article{Mankel.2004,
|
||||||
|
Title = {{Pattern recognition and event reconstruction in particle
|
||||||
|
physics experiments}},
|
||||||
|
Author = {Mankel, Rainer},
|
||||||
|
Journal = {Rept.Prog.Phys.},
|
||||||
|
Year = {2004},
|
||||||
|
Pages = {553},
|
||||||
|
Volume = {67},
|
||||||
|
Archiveprefix = {arXiv},
|
||||||
|
Doi = {10.1088/0034-4885/67/4/R03},
|
||||||
|
Eprint = {physics/0402039},
|
||||||
|
File = {Published version:Mankel.2004.pdf:PDF},
|
||||||
|
Owner = {NT},
|
||||||
|
Primaryclass = {physics},
|
||||||
|
Reportnumber = {DESY-04-008},
|
||||||
|
Slaccitation = {%%CITATION = PHYSICS/0402039;%%},
|
||||||
|
Timestamp = {2015-01-07}
|
||||||
|
}
|
||||||
|
|
||||||
@Article{MarcianoSanda.1977,
|
@Article{MarcianoSanda.1977,
|
||||||
Title = {{Exotic Decays of the Muon and Heavy Leptons in Gauge
|
Title = {{Exotic Decays of the Muon and Heavy Leptons in Gauge
|
||||||
Theories}},
|
Theories}},
|
||||||
@@ -1812,6 +2121,7 @@
|
|||||||
Month = {Mar},
|
Month = {Mar},
|
||||||
Pages = {1106--1110},
|
Pages = {1106--1110},
|
||||||
Volume = {43},
|
Volume = {43},
|
||||||
|
|
||||||
Doi = {10.1103/PhysRevC.43.1106},
|
Doi = {10.1103/PhysRevC.43.1106},
|
||||||
File = {Published version:MartoffCummings.etal.1991.pdf:PDF},
|
File = {Published version:MartoffCummings.etal.1991.pdf:PDF},
|
||||||
Issue = {3},
|
Issue = {3},
|
||||||
@@ -1856,7 +2166,7 @@
|
|||||||
@Article{MeasdayStocki.etal.2007,
|
@Article{MeasdayStocki.etal.2007,
|
||||||
Title = {$\gamma$ rays from muon capture in Al 27 and natural Si},
|
Title = {$\gamma$ rays from muon capture in Al 27 and natural Si},
|
||||||
Author = {Measday, David F and Stocki, Trevor J and Moftah, Belal A and Tam, Heywood},
|
Author = {Measday, David F and Stocki, Trevor J and Moftah, Belal A and Tam, Heywood},
|
||||||
Journal = {Physical Review C},
|
Journal = {Phys. Rev. C},
|
||||||
Year = {2007},
|
Year = {2007},
|
||||||
Number = {3},
|
Number = {3},
|
||||||
Pages = {035504},
|
Pages = {035504},
|
||||||
@@ -2284,7 +2594,6 @@
|
|||||||
Pages = {135--141},
|
Pages = {135--141},
|
||||||
Volume = {19},
|
Volume = {19},
|
||||||
|
|
||||||
__markedentry = {[NT:]},
|
|
||||||
Doi = {10.1103/PhysRevC.19.135},
|
Doi = {10.1103/PhysRevC.19.135},
|
||||||
File = {Published version:SchlepuetzComiso.etal.1979.pdf:PDF},
|
File = {Published version:SchlepuetzComiso.etal.1979.pdf:PDF},
|
||||||
Issue = {1},
|
Issue = {1},
|
||||||
@@ -2348,7 +2657,7 @@
|
|||||||
@Article{SobottkaWills.1968,
|
@Article{SobottkaWills.1968,
|
||||||
Title = {Energy Spectrum of Charged Particles Emitted Following Muon Capture in Si 28},
|
Title = {Energy Spectrum of Charged Particles Emitted Following Muon Capture in Si 28},
|
||||||
Author = {Sobottka, Stanley E and Wills, Edward L},
|
Author = {Sobottka, Stanley E and Wills, Edward L},
|
||||||
Journal = {Physical Review Letters},
|
Journal = {Phys. Rev. Lett.},
|
||||||
Year = {1968},
|
Year = {1968},
|
||||||
Number = {12},
|
Number = {12},
|
||||||
Pages = {596},
|
Pages = {596},
|
||||||
@@ -2471,7 +2780,6 @@
|
|||||||
Pages = {MOLT007},
|
Pages = {MOLT007},
|
||||||
Volume = {C0303241},
|
Volume = {C0303241},
|
||||||
|
|
||||||
__markedentry = {[NT:6]},
|
|
||||||
Archiveprefix = {arXiv},
|
Archiveprefix = {arXiv},
|
||||||
Eprint = {physics/0306116},
|
Eprint = {physics/0306116},
|
||||||
File = {arXiv v1:VerkerkeKirkby.2003-eprintv1.pdf:PDF},
|
File = {arXiv v1:VerkerkeKirkby.2003-eprintv1.pdf:PDF},
|
||||||
|
|||||||
@@ -21,21 +21,22 @@ following nuclear muon capture\\
|
|||||||
\vspace{2mm}
|
\vspace{2mm}
|
||||||
for the COMET experiment}
|
for the COMET experiment}
|
||||||
\author{Nam Hoai Tran}
|
\author{Nam Hoai Tran}
|
||||||
\date{September, 2014}
|
\date{October, 2014}
|
||||||
|
|
||||||
\begin{document}
|
\begin{document}
|
||||||
%\begin{frontmatter}
|
\begin{frontmatter}
|
||||||
%\input{chapters/frontmatter}
|
\input{chapters/frontmatter}
|
||||||
%\end{frontmatter}
|
\end{frontmatter}
|
||||||
|
|
||||||
\mainmatter
|
\mainmatter
|
||||||
%\input{chapters/chap1_intro}
|
%%%\input{chapters/chap1_intro}
|
||||||
%\input{chapters/chap2_mu_e_conv}
|
\input{chapters/chap2_mu_e_conv}
|
||||||
%\input{chapters/chap3_comet}
|
\input{chapters/chap3_comet}
|
||||||
%\input{chapters/chap4_alcap_phys}
|
\input{chapters/chap4_alcap_phys}
|
||||||
%\input{chapters/chap5_alcap_setup}
|
\input{chapters/chap5_alcap_setup}
|
||||||
\input{chapters/chap6_analysis}
|
\input{chapters/chap6_analysis}
|
||||||
%\input{chapters/chap7_results}
|
\input{chapters/chap7_results}
|
||||||
|
\input{chapters/chap8_conclusions}
|
||||||
|
|
||||||
\begin{backmatter}
|
\begin{backmatter}
|
||||||
\input{chapters/backmatter}
|
\input{chapters/backmatter}
|
||||||
|
|||||||
Reference in New Issue
Block a user